The Schneider Electric A9DE3610 is a residual current circuit breaker with overcurrent protection RCBO from the Acti9 iCV40N range, designed to combine overload, short-circuit, and earth leakage protection in a single device. It features 1P+N configuration, rated current of 10 A, C tripping curve, 30 mA residual current sensitivity, and type AC residual protection, offering a compact solution for single-phase distribution circuits.
Its breaking capacity reaches 6 kA at 230 V AC according to EN/IEC 61009-2-1. The residual current protection is instantaneous and voltage-independent, while the thermal-magnetic trip unit protects the phase conductor against overloads and short circuits. With a width of 36 mm, equivalent to 2 DIN modules of 18 mm, it combines thermal-magnetic and residual protection while taking up minimal space in the electrical panel.
The A9DE3610 is an RCBO, meaning a residual current device that also includes overcurrent protection. This design makes it possible, in certain configurations, to replace a separate miniature circuit breaker and residual current device with a single unit that performs both functions.
The device protects the circuit against overloads through a thermal trip unit, against short circuits through magnetic tripping, and against residual currents or earth leakage through its integrated 30 mA residual current protection.
The Schneider Electric iCV40N A9DE3610 features a 1P+N configuration. The phase pole includes thermal-magnetic protection, while the neutral is disconnected simultaneously with the phase. Schneider Electric specifies that the neutral is located on the left.
Feature Value Total number of poles 1P + N Protected poles 1 Neutral position Left Rated current 10 AThe thermal-magnetic protection has a rated current of 10 A and C tripping curve. Schneider Electric specifies a magnetic tripping threshold between 5 and 10 times the rated current.
The C curve is one of the most widely used in distribution installations and is suitable for many circuits with moderate inrush currents. Final selection should always take into account conductor cross-section, load characteristics, available short-circuit current, and applicable regulations.
The A9DE3610 incorporates residual current protection with a nominal sensitivity of 30 mA. This sensitivity level is commonly used as additional protection against electric shock in circuits where regulations require this level of protection.
Schneider Electric expressly indicates this device for protecting people against electric shock, while combining residual current protection with overload and short-circuit protection.
The residual current protection is type AC, meaning it is designed to detect sinusoidal alternating residual currents.
The residual current class should always be selected according to the loads connected to the circuit. Electronic equipment, variable speed drives, appliances with power electronics, and other loads may require a different residual current device class, such as type A or A-SI, depending on the installation characteristics.
The earth leakage protection operates instantaneously. The device does not include an intentional time delay, so it is designed to disconnect the circuit quickly when the residual current exceeds the set tripping conditions.
Schneider Electric specifies that the residual current tripping technology is voltage-independent. This feature corresponds to an electromechanical architecture in which the main residual function does not depend on an external auxiliary electronic supply.
The iCV40N A9DE3610 has a breaking capacity Icn of 6000 A at 230 V AC, 50/60 Hz, in accordance with EN/IEC 61009-2-1. Its service breaking capacity Ics is also 6000 A, equivalent to 100% of Icn under the conditions specified by Schneider Electric.
Parameter Value Breaking capacity Icn 6 kA at 230 V AC Service breaking capacity Ics 6 kA, 100% of Icn Standard EN/IEC 61009-2-1 Limiting class 3The device has limiting class 3 according to EN/IEC 61009-2-1. This capability helps limit the energy passing through the circuit during a short circuit, reducing the thermal and electrodynamic stress on downstream conductors and equipment.
The front of the iCV40N includes a red mechanical earth fault indicator. This signal makes it easier to identify a trip caused by the residual current protection and helps distinguish it during troubleshooting and maintenance tasks.
This feature is especially practical in panels with multiple circuits, as it allows the tripped device to be located more quickly.
One of the main advantages of the A9DE3610 is that it integrates both protections in a width of only 36 mm, equivalent to two 18 mm DIN modules. This helps optimize the available space inside distribution electrical panels.
Dimension Value Height 85 mm Width 36 mm Depth 73 mm Installation depth 44 mm 9 mm steps 4 18 mm DIN modules 2 Approximate weight 210 gThe Schneider Electric Acti9 iCV40N is designed for DIN rail mounting using a clip-on system. Its modular format makes installation alongside other miniature circuit breakers, residual current devices, contactors, and Acti9 devices inside the electrical panel easier.
The device supports comb busbar distribution systems from both the top and bottom, simplifying the wiring of properly configured modular panels.
The A9DE3610 uses tunnel terminals at both the top and bottom. Schneider Electric specifies the following connection capacities:
Conductor type Cross-section Rigid conductor 1 to 16 mm² Flexible conductor 1 to 10 mm² Stripping length 14 mm Tightening torque 2 NmSchneider Electric specifies a high service life for the device, with a mechanical durability of 20,000 cycles and electrical durability of 20,000 cycles under the conditions established by the manufacturer.
The A9DE3610 has an IP20 protection rating according to IEC 60529. When correctly installed inside a suitable modular enclosure, the manufacturer indicates an IP40 level on the part corresponding to the installed device.
The Schneider Electric A9DE3610 is designed to protect single-phase circuits where both 10 A thermal-magnetic protection and 30 mA type AC residual current protection are required.
By combining thermal-magnetic and residual protection in a single device, the iCV40N provides individualized circuit protection. In the event of an anomaly in a circuit protected by its own RCBO, disconnection can be limited to that circuit instead of necessarily affecting other circuits that depend on a common residual current device.
This configuration can also simplify panel design and make fault diagnosis easier, especially thanks to the front mechanical earth fault indicator.
The Schneider Electric A9DE3610 is designed in accordance with EN/IEC 61009-2-1, the standard applicable to residual current circuit breakers with integrated overcurrent protection. Schneider Electric also specifies quality marks and certifications such as VDE, IMQ, and EAC for this reference.
The Schneider Electric A9DE3610 Acti9 iCV40N offers complete protection for 10 A single-phase circuits in just two DIN modules, combining C curve, 6 kA breaking capacity, and instantaneous 30 mA type AC residual protection. Its compact format, earth fault indicator, and voltage-independent residual protection make it a practical solution for residential and tertiary electrical panels.