ICV40N Differential 1P+N C 10A 30mA Class AC with reference A9DE3610 from the brand SCHNEIDER ELECTRIC
ICV40N Differential 1P+N C 10A 30mA Class AC with reference A9DE3610 from the brand SCHNEIDER ELECTRIC
SCHNEIDER ELECTRIC

ICV40N Differential 1P+N C 10A 30mA Class AC

REF
A9DE3610
(0)
132.20 €
€132.20
€603.12
Up to -6% for professionals. Discover it.
Schneider Electric Acti9 iCV40N 1P+N 10 A C-curve magnetothermal circuit breaker, 30 mA type AC, 6 kA breaking capacity, instantaneous trip, and 35 mm DIN rail mounting.
Buy now and receive it between 20 and November 23
Express delivery
Get +133 +265 Sumis for the purchase
Receive 2x Sumis for a limited time
More about the product

Information about ICV40N Differential 1P+N C 10A 30mA Class AC

The Schneider Electric A9DE3610 is a residual current circuit breaker with overcurrent protection RCBO from the Acti9 iCV40N range, designed to combine overload, short-circuit, and earth leakage protection in a single device. It features 1P+N configuration, rated current of 10 A, C tripping curve, 30 mA residual current sensitivity, and type AC residual protection, offering a compact solution for single-phase distribution circuits.

Its breaking capacity reaches 6 kA at 230 V AC according to EN/IEC 61009-2-1. The residual current protection is instantaneous and voltage-independent, while the thermal-magnetic trip unit protects the phase conductor against overloads and short circuits. With a width of 36 mm, equivalent to 2 DIN modules of 18 mm, it combines thermal-magnetic and residual protection while taking up minimal space in the electrical panel.

Key features of the Schneider Electric A9DE3610

  • RCBO residual current circuit breaker with overcurrent protection.
  • Brand: Schneider Electric.
  • Range: Acti9 iCV40.
  • Model: iCV40N.
  • Reference: A9DE3610.
  • Configuration: 1P+N.
  • Number of protected poles: 1.
  • Neutral position: left.
  • Rated current: 10 A.
  • Thermal-magnetic curve: C.
  • Residual current sensitivity: 30 mA.
  • Residual current class: type AC.
  • Residual current tripping: instantaneous.
  • Voltage-independent residual current tripping technology.
  • Protection against overloads and short circuits.
  • Integrated protection against earth leakage currents.
  • Breaking capacity Icn: 6 kA at 230 V AC.
  • Service breaking capacity Ics: 6 kA.
  • Limiting class: 3.
  • Rated operational voltage: 230 V AC.
  • Frequency: 50/60 Hz.
  • Rated insulation voltage Ui: 400 V.
  • Impulse withstand voltage Uimp: 4 kV.
  • DIN rail mounting.
  • Width: 36 mm / 2 DIN modules.
  • Protection rating: IP20.

Thermal-magnetic and residual protection in one device

The A9DE3610 is an RCBO, meaning a residual current device that also includes overcurrent protection. This design makes it possible, in certain configurations, to replace a separate miniature circuit breaker and residual current device with a single unit that performs both functions.

The device protects the circuit against overloads through a thermal trip unit, against short circuits through magnetic tripping, and against residual currents or earth leakage through its integrated 30 mA residual current protection.

1P+N configuration

The Schneider Electric iCV40N A9DE3610 features a 1P+N configuration. The phase pole includes thermal-magnetic protection, while the neutral is disconnected simultaneously with the phase. Schneider Electric specifies that the neutral is located on the left.

Feature Value Total number of poles 1P + N Protected poles 1 Neutral position Left Rated current 10 A

10 A C curve

The thermal-magnetic protection has a rated current of 10 A and C tripping curve. Schneider Electric specifies a magnetic tripping threshold between 5 and 10 times the rated current.

The C curve is one of the most widely used in distribution installations and is suitable for many circuits with moderate inrush currents. Final selection should always take into account conductor cross-section, load characteristics, available short-circuit current, and applicable regulations.

30 mA residual current protection

The A9DE3610 incorporates residual current protection with a nominal sensitivity of 30 mA. This sensitivity level is commonly used as additional protection against electric shock in circuits where regulations require this level of protection.

Schneider Electric expressly indicates this device for protecting people against electric shock, while combining residual current protection with overload and short-circuit protection.

Type AC residual current protection

The residual current protection is type AC, meaning it is designed to detect sinusoidal alternating residual currents.

The residual current class should always be selected according to the loads connected to the circuit. Electronic equipment, variable speed drives, appliances with power electronics, and other loads may require a different residual current device class, such as type A or A-SI, depending on the installation characteristics.

Instantaneous residual current tripping

The earth leakage protection operates instantaneously. The device does not include an intentional time delay, so it is designed to disconnect the circuit quickly when the residual current exceeds the set tripping conditions.

Voltage-independent residual current tripping

Schneider Electric specifies that the residual current tripping technology is voltage-independent. This feature corresponds to an electromechanical architecture in which the main residual function does not depend on an external auxiliary electronic supply.

6 kA breaking capacity

The iCV40N A9DE3610 has a breaking capacity Icn of 6000 A at 230 V AC, 50/60 Hz, in accordance with EN/IEC 61009-2-1. Its service breaking capacity Ics is also 6000 A, equivalent to 100% of Icn under the conditions specified by Schneider Electric.

Parameter Value Breaking capacity Icn 6 kA at 230 V AC Service breaking capacity Ics 6 kA, 100% of Icn Standard EN/IEC 61009-2-1 Limiting class 3

Limiting class 3

The device has limiting class 3 according to EN/IEC 61009-2-1. This capability helps limit the energy passing through the circuit during a short circuit, reducing the thermal and electrodynamic stress on downstream conductors and equipment.

Mechanical earth fault indicator

The front of the iCV40N includes a red mechanical earth fault indicator. This signal makes it easier to identify a trip caused by the residual current protection and helps distinguish it during troubleshooting and maintenance tasks.

This feature is especially practical in panels with multiple circuits, as it allows the tripped device to be located more quickly.

Electrical characteristics

Feature Specification Rated current In 10 A Configuration 1P+N Protected poles 1 Curve C Thermal-magnetic technology Thermal-magnetic Magnetic threshold 5-10 x In Residual current sensitivity 30 mA Residual current class AC Residual current tripping Instantaneous Residual current technology Voltage-independent Rated operational voltage Ue 230 V AC Frequency 50/60 Hz Insulation voltage Ui 400 V Impulse withstand voltage Uimp 4 kV

Compact 2 DIN module format

One of the main advantages of the A9DE3610 is that it integrates both protections in a width of only 36 mm, equivalent to two 18 mm DIN modules. This helps optimize the available space inside distribution electrical panels.

Dimension Value Height 85 mm Width 36 mm Depth 73 mm Installation depth 44 mm 9 mm steps 4 18 mm DIN modules 2 Approximate weight 210 g

DIN rail mounting

The Schneider Electric Acti9 iCV40N is designed for DIN rail mounting using a clip-on system. Its modular format makes installation alongside other miniature circuit breakers, residual current devices, contactors, and Acti9 devices inside the electrical panel easier.

The device supports comb busbar distribution systems from both the top and bottom, simplifying the wiring of properly configured modular panels.

Terminals and connection

The A9DE3610 uses tunnel terminals at both the top and bottom. Schneider Electric specifies the following connection capacities:

Conductor type Cross-section Rigid conductor 1 to 16 mm² Flexible conductor 1 to 10 mm² Stripping length 14 mm Tightening torque 2 Nm

Durability

Schneider Electric specifies a high service life for the device, with a mechanical durability of 20,000 cycles and electrical durability of 20,000 cycles under the conditions established by the manufacturer.

IP20 protection

The A9DE3610 has an IP20 protection rating according to IEC 60529. When correctly installed inside a suitable modular enclosure, the manufacturer indicates an IP40 level on the part corresponding to the installed device.

Environmental conditions

Feature Value Operating ambient temperature -5 to +60 °C Storage temperature -40 to +85 °C Relative humidity 95% at 55 °C Maximum operating altitude 2000 m Pollution degree 3 Overvoltage category III

Applications of the Acti9 iCV40N

The Schneider Electric A9DE3610 is designed to protect single-phase circuits where both 10 A thermal-magnetic protection and 30 mA type AC residual current protection are required.

  • Residential electrical panels.
  • Commercial and tertiary installations.
  • Lighting circuits.
  • Auxiliary circuits.
  • Secondary distribution panels.
  • Installations where space savings are needed through an RCBO.
  • 230 V single-phase circuits compatible with a 10 A C curve.

Advantages of using an RCBO

By combining thermal-magnetic and residual protection in a single device, the iCV40N provides individualized circuit protection. In the event of an anomaly in a circuit protected by its own RCBO, disconnection can be limited to that circuit instead of necessarily affecting other circuits that depend on a common residual current device.

This configuration can also simplify panel design and make fault diagnosis easier, especially thanks to the front mechanical earth fault indicator.

Standards and certifications

The Schneider Electric A9DE3610 is designed in accordance with EN/IEC 61009-2-1, the standard applicable to residual current circuit breakers with integrated overcurrent protection. Schneider Electric also specifies quality marks and certifications such as VDE, IMQ, and EAC for this reference.

Schneider Electric A9DE3610 technical summary

Feature Specification Brand Schneider Electric Range Acti9 iCV40 Model iCV40N Reference A9DE3610 Type RCBO residual current circuit breaker with overcurrent protection Poles 1P+N Protected poles 1 Neutral Left Rated current 10 A Curve C Residual current sensitivity 30 mA Residual current class Type AC Residual current delay Instantaneous Breaking capacity Icn 6 kA Rated voltage 230 V AC Frequency 50/60 Hz Ui 400 V Uimp 4 kV Limiting class 3 Mounting DIN rail Width 36 mm / 2 DIN modules Dimensions 85 x 36 x 73 mm Approximate weight 210 g Protection rating IP20 Standard EN/IEC 61009-2-1 EAN 3606489444228

The Schneider Electric A9DE3610 Acti9 iCV40N offers complete protection for 10 A single-phase circuits in just two DIN modules, combining C curve, 6 kA breaking capacity, and instantaneous 30 mA type AC residual protection. Its compact format, earth fault indicator, and voltage-independent residual protection make it a practical solution for residential and tertiary electrical panels.

Specifications
Manufacturer
SCHNEIDER ELECTRIC
Reference
A9DE3610
SKU
SCH172B3E93
Object
Circuit breaker
Number of poles
1P+N, 1P + N
Assembly
DIN rail. Clip adjustable.
Nominal current
10 A
Network type
AC
Protection rating
IP20
Frequency
50/60 Hz
Datasheets
Reviews
Returns within 30 days
Shop with peace of mind. If something goes wrong, we'll take care of it.
After-sales service
Any questions? Our support team will be happy to help you.
Pay how and when you want
Card, bank transfer, PayPal... Installment? We have them all.
GroupSumi is your online distributor for construction, electrical material and climate control.
All rights reserved © 2026 GroupSumi