The Schneider Electric Acti9 iCV40N A9DE3616 is a residual current circuit breaker with overcurrent protection, also known as an RCBO, which combines in a single device thermal-magnetic protection against overloads and short circuits with residual current protection against earth leakage currents. It features a 1P+N configuration, rated current of 16 A, C curve, 30 mA residual current sensitivity and AC class.
Designed for single-phase 230 V AC circuits, it offers a rated breaking capacity Icn of 6 kA in accordance with EN/IEC 61009-2-1. Its compact 36 mm format provides thermal-magnetic and residual current protection while occupying only two standard modules in the electrical panel.
Unlike a conventional residual current device, the Acti9 iCV40N A9DE3616 also incorporates overcurrent protection, allowing an individual circuit to be protected by a single device.
The A9DE3616 reference has a 1P+N configuration, with one protected pole and neutral disconnection. The neutral is located on the left side of the device.
Its C curve has a magnetic trip threshold between 5 and 10 times the rated current, a common feature in distribution circuits with moderate inrush currents.
The integrated residual current protection has a 30 mA sensitivity and AC class. It is designed to detect sinusoidal alternating residual currents.
The 30 mA sensitivity is intended to provide additional protection for people against certain electric shock risks, within a properly designed installation and in compliance with applicable regulations.
Schneider Electric specifies for the A9DE3616 a rated breaking capacity Icn of 6000 A at 230 V AC in accordance with EN/IEC 61009-2-1.
The Acti9 iCV40N incorporates the VisiTrip and VisiSafe technologies characteristic of the Acti9 range.
VisiTrip makes it easy to visually identify a trip caused by an electrical fault, helping to quickly locate the affected circuit. VisiSafe provides a visible indication of the open contact state to facilitate inspection and maintenance operations.
The Schneider Electric A9DE3616 is suitable for isolation in accordance with EN/IEC 60947-2, allowing the circuit to be isolated within the conditions established by the manufacturer.
The integration of residual current and thermal-magnetic protection in a single device reduces the space required in the panel. The A9DE3616 has a width of 36 mm, equivalent to 4 x 9 mm pitches or 2 standard 18 mm modules.
The residual current circuit breaker with overcurrent protection is designed for clip-on mounting on DIN rail. It supports supply and connection from both the top and bottom, making integration into modular panels easier.
It is also compatible with suitable comb busbar systems from the Acti9 range.
The tunnel terminals allow connection of rigid and flexible conductors:
The Acti9 iCV40N is designed to deliver a long service life in electrical distribution installations.
The Schneider Electric A9DE3616 has an IP20 protection rating as a device. Properly installed inside a suitable modular enclosure, it can achieve a protection rating of up to IP40.
The A9DE3616 is developed in accordance with EN/IEC 61009-2-1, the standard applicable to residual current circuit breakers with integrated overcurrent protection.
The product also has certifications and quality marks such as CE, IMQ, EAC and VDE according to the manufacturer's technical documentation.
The Schneider Electric Acti9 iCV40N A9DE3616 1P+N, 16 A, C curve and 30 mA type AC protects a single-phase circuit against overloads, short circuits and leakage currents with a single device. Its 6 kA breaking capacity, compact 36 mm format, VisiTrip and VisiSafe technologies and DIN rail mounting make it a practical solution for residential and commercial distribution boards.