Schneider Electric Acti9 iCV40N combined switch 1P+N 20A C curve, 30 mA type A-SI residual current protection and 6 kA breaking capacity for overloads, short circuits and leakage currents.
Buy now and receive it between 20 and November 23
Express free delivery
Get +168 +335 Sumis for the purchase
Receive 2x Sumis for a limited time
More about the product

Information about ICV40N Differential 1P+N C 20A 30mA Class ASI

The Schneider Electric Acti9 iCV40N A9DF3620 is a combined residual current circuit breaker with overcurrent protection RCBO 1P+N, 20 A, C curve and 30 mA sensitivity type A-SI. It integrates in a single device the thermal-magnetic protection against overloads and short circuits and the residual current protection against earth leakage currents, simplifying the electrical panel design and reducing the number of devices required.

This reference offers a rated breaking capacity of 6 kA at 230 V AC in accordance with EN/IEC 61009-2-1. Its type A-SI residual current protection, also known as super immune, provides greater immunity to electrical disturbances, reducing the risk of nuisance tripping in installations with electronic equipment and other loads likely to generate interference.

Combined thermal-magnetic and residual current protection

The Acti9 iCV40N combines two essential electrical protection functions in a single device. The thermal-magnetic trip unit protects the circuit against overloads and short circuits, while the residual current function detects earth leakage currents.

This RCBO design allows each circuit to be protected individually without the need to install a separate MCB and RCD, helping to optimize the available space in the panel.

1P+N 20 A with C curve

Reference A9DF3620 features a 1 protected pole plus neutral configuration, with the neutral on the left side. Its rated current is 20 A and it uses a C tripping curve.

The magnetic operating threshold is between 5 and 10 times the rated current, a feature suitable for many distribution circuits that may present moderate inrush currents.

  • Configuration: 1P+N.
  • Protected poles: 1.
  • Neutral position: left.
  • Rated current: 20 A.
  • Tripping curve: C.
  • Trip unit: thermal-magnetic.
  • Magnetic threshold: 5-10 x In.

30 mA super immune type A-SI residual current protection

The residual current protection offers a sensitivity of 30 mA and belongs to the type A-SI class. This technology is designed to detect residual currents corresponding to type A devices, while also incorporating greater immunity to electrical disturbances that could cause unwanted disconnections.

Schneider Electric especially recommends A-SI technology in installations subject to electrical disturbances or in certain demanding environments. This feature is particularly useful in circuits with electronic loads and equipment that may generate disturbances on the network.

  • Residual current sensitivity: 30 mA.
  • Residual current class: type A-SI.
  • Residual current delay: instantaneous.
  • Residual current technology: voltage independent.
  • Earth leakage protection: integrated.

6 kA breaking capacity

The Schneider Electric A9DF3620 has a rated breaking capacity Icn of 6,000 A at 230 V AC and 50/60 Hz, in accordance with EN/IEC 61009-2-1.

Its service breaking capacity Ics also reaches 6 kA, equivalent to 100% of Icn, offering a high interrupting capacity within the operating conditions specified by Schneider Electric.

  • Icn breaking capacity: 6 kA.
  • Ics service breaking capacity: 6 kA.
  • Ics relative to Icn: 100%.
  • Limitation class: 3.

Operation at 230 V AC

The iCV40N A9DF3620 is designed for single-phase installations at 230 V AC, 50/60 Hz. Its rated insulation voltage is 400 V AC and it has an impulse withstand voltage of 4 kV.

  • Rated operating voltage: 230 V AC.
  • Frequency: 50/60 Hz.
  • Rated insulation voltage Ui: 400 V AC.
  • Impulse withstand voltage Uimp: 4 kV.
  • Overvoltage category: III.
  • Pollution degree: 3.

Front indication of status and faults

The circuit breaker includes local on/off indication and fault indication, making it easier to identify the status of the protected circuit and helping with diagnostics and maintenance operations.

It also features a contact position indicator and a front operating lever.

Suitable for isolation

The A9DF3620 is suitable for isolation in accordance with EN/IEC 61009-2-1. This feature allows it to be used to electrically isolate the protected circuit during maintenance operations, always following the corresponding safety procedures.

Compact DIN rail format

The Schneider Electric Acti9 iCV40N is designed for clip-on mounting on a DIN rail. Its width is only 36 mm, allowing thermal-magnetic and residual current protection to be integrated while taking up minimal space inside the panel.

  • Height: 85 mm.
  • Width: 36 mm.
  • Depth: 73 mm.
  • 9 mm modules: 4.
  • Weight: 210 g.
  • Color: white.
  • Mounting: clip-on DIN rail.

Compatibility with comb busbar

The device allows connection using compatible distribution blocks and comb busbars from both the top and bottom, facilitating electrical organization and distribution in modular panels.

The connection distance between phase and neutral is 9 mm.

Conductor connection

The tunnel terminals allow rigid and flexible conductors to be connected from the top or bottom.

  • Rigid conductor: 1 to 16 mm².
  • Flexible conductor: 1 to 10 mm².
  • Strip length: 14 mm.
  • Tightening torque: 2 Nm.

High durability

The Acti9 iCV40N is designed to provide a long service life inside the electrical panel. Schneider Electric declares a mechanical durability of 20,000 cycles and an electrical durability of 20,000 cycles.

  • Mechanical durability: 20,000 cycles.
  • Electrical durability: 20,000 cycles.

IP20 protection and wide temperature range

The device has an IP20 protection rating as a standalone component and can reach IP40 when installed inside a suitable modular enclosure.

  • Protection rating: IP20.
  • Protection in modular enclosure: up to IP40.
  • Operating temperature: -25 to 60 °C.
  • Storage temperature: -40 to 85 °C.
  • Relative humidity: up to 95% at 55 °C.
  • Maximum operating altitude: 2,000 m.

Schneider Electric A9DF3620 technical characteristics

  • Brand: Schneider Electric.
  • Range: Acti9.
  • Series: iCV40.
  • Model: iCV40N.
  • Reference: A9DF3620.
  • Type: combined residual current circuit breaker with overcurrent protection RCBO.
  • Configuration: 1P+N.
  • Protected poles: 1.
  • Neutral position: left.
  • Rated current: 20 A.
  • Tripping curve: C.
  • Trip unit: thermal-magnetic.
  • Magnetic threshold: 5-10 x In.
  • Residual current sensitivity: 30 mA.
  • Residual current class: A-SI.
  • Residual current delay: instantaneous.
  • Residual current technology: voltage independent.
  • Rated voltage: 230 V AC.
  • Frequency: 50/60 Hz.
  • Icn breaking capacity: 6 kA.
  • Ics service breaking capacity: 6 kA.
  • Limitation class: 3.
  • Insulation voltage Ui: 400 V AC.
  • Impulse withstand voltage Uimp: 4 kV.
  • Suitable for isolation: yes.
  • Fault indication: yes.
  • Contact position indicator: yes.
  • Mounting: DIN rail.
  • Dimensions: 85 x 36 x 73 mm.
  • Weight: 210 g.
  • Rigid conductor: 1-16 mm².
  • Flexible conductor: 1-10 mm².
  • Strip length: 14 mm.
  • Tightening torque: 2 Nm.
  • Mechanical durability: 20,000 cycles.
  • Electrical durability: 20,000 cycles.
  • Protection rating: IP20, up to IP40 in enclosure.
  • Operating temperature: -25 to 60 °C.
  • Standard: EN/IEC 61009-2-1.

The Schneider Electric Acti9 iCV40N A9DF3620 is a compact solution for individually protecting electrical circuits against overloads, short circuits and leakage currents. Its 20 A rating, C curve, 30 mA sensitivity, super immune A-SI residual current protection and 6 kA breaking capacity make it suitable for electrical panels that require complete protection and high immunity to disturbances.

Specifications
Manufacturer
SCHNEIDER ELECTRIC
Reference
A9DF3620
SKU
SCH2D8C2235
Object
Circuit breaker
Number of poles
1P+N, 1P + N
Assembly
DIN rail. Clip adjustable.
Nominal current
20 A
Network type
AC
Protection rating
IP20
Frequency
50/60 Hz
Datasheets
Reviews
Returns within 30 days
Shop with peace of mind. If something goes wrong, we'll take care of it.
After-sales service
Any questions? Our support team will be happy to help you.
Pay how and when you want
Card, bank transfer, PayPal... Installment? We have them all.
GroupSumi is your online distributor for construction, electrical material and climate control.
All rights reserved © 2026 GroupSumi