The Schneider Electric Acti9 iID A9R10225 residual current circuit breaker is a bipolar RCD with 25 A rating and high 10 mA sensitivity, designed to detect earth leakage currents and disconnect the circuit instantly. Its protection is type AC, suitable for detecting sinusoidal alternating residual currents, and it uses a voltage-independent tripping technology.
This residual current device from the Acti9 range is intended for single-phase networks of 220-240 V AC at 50/60 Hz. It includes a front mechanical earth-fault trip indicator, contact position indication, and modular DIN rail mounting. Its 10 mA sensitivity provides a higher detection level than conventional 30 mA RCDs for applications where this feature is required.
The A9R10225 has a rated residual current sensitivity of 10 mA. The device continuously monitors the balance between the current flowing through phase and neutral and trips when it detects a residual current that reaches the specified tripping conditions.
The 10 mA sensitivity allows it to detect smaller leakage currents than a conventional 30 mA RCD, so it can be used in circuits where the electrical design requires a particularly high sensitivity level.
This reference belongs to class AC. Type AC RCDs are designed to detect sinusoidal alternating residual currents.
When connected loads include electronics capable of generating pulsating residual currents or DC components, it should be checked whether the installation requires a type A, A-SI, or another suitable class instead of type AC.
The A9R10225 is an instantaneous trip residual current device, so it does not include an intentional delay intended to achieve time selectivity with other residual current devices installed upstream or downstream.
When an installation requires selective coordination between different protection levels, the corresponding devices and sensitivities must be selected according to the electrical diagram.
Schneider Electric specifies a voltage-independent residual current tripping technology. Detection and tripping in the event of leakage do not depend on an independent auxiliary electronic supply.
This feature is part of the electromechanical architecture used by the Acti9 iID range to provide residual current protection.
The device has a 2P bipolar configuration, with the neutral pole on the left. When tripping occurs, the mechanism opens both poles of the circuit simultaneously.
This configuration is especially suited to 230 V single-phase circuits where phase and neutral must be disconnected together.
The rated current of the A9R10225 is 25 A. This value represents the current the device can carry under its nominal operating conditions.
The residual current device does not include overload or short-circuit protection. For this reason, it must be used together with a miniature circuit breaker or another overcurrent protection device correctly sized.
Schneider Electric specifies a rated conditional short-circuit current of 10 kA for this model when used with the appropriate upstream protection.
The device’s rated making and breaking capacity is 1500 A for both Im and Idm.
The device is designed for networks of:
The Acti9 iID includes a red mechanical earth-fault indicator. This indication makes it possible to visually distinguish an opening caused by residual current protection and helps identify the affected circuit during troubleshooting.
The front indication can reduce the time needed to locate the device that has tripped within panels with multiple protections.
The device includes contact position indication. Schneider Electric uses the VisiSafe function to provide a reliable visual indication of the open state of the poles, making downstream maintenance tasks easier.
Schneider Electric states that the Acti9 iID is suitable for isolation functions within the conditions established by the applicable IEC 61008 standards.
It can therefore be used as part of the panel’s isolation and residual current protection system, always respecting electrical safety procedures.
The device is installed by clip-on mounting on a DIN rail. It occupies four 9 mm pitches, equivalent to 2 standard 18 mm modules.
Its modular format makes installation alongside MCBs, surge protection devices, contactors, and other Acti9 devices easier.
The terminals allow conductors to be connected from both the top and bottom:
The Acti9 iID supports integration with compatible comb busbar distribution systems, simplifying wiring and electrical distribution inside the panel.
Schneider Electric specifies:
These features make it suitable for residential, commercial, and tertiary installations with a long expected service life.
The device has an IP20 protection rating according to IEC 60529. Installed inside a compatible modular enclosure, the assembly can reach IP40 depending on the panel configuration.
The Acti9 iID is compatible with the Acti9 captive padlock locking device. This option facilitates maintenance and electrical lockout operations when accidental reconnection must be prevented.
The A9R10225 is an RCCB residual current circuit breaker. Its function is to detect residual currents or earth leakage, but it does not protect against overloads or short circuits by itself.
To obtain complete circuit protection, it must be coordinated with an MCB or equivalent device suitable for the conductor cross-section and the available short-circuit current.
Due to its 10 mA sensitivity, it can be used in circuits where the installation design requires high-sensitivity residual current protection, for example:
The Schneider Electric Acti9 iID A9R10225 complies with the applicable standards for RCCB residual current circuit breakers, including:
The Schneider Electric A9R10225 combines 10 mA residual current sensitivity, 25 A rated current, and a bipolar configuration in a modular device only 36 mm wide. Its instantaneous operation, voltage-independent tripping, and mechanical fault indicator make it possible to integrate high-sensitivity residual current protection into single-phase panels.
The 10 kA conditional short-circuit current, 6 kV impulse withstand, terminals for rigid conductors up to 35 mm², and mechanical durability of 20,000 cycles complete the features of this Acti9 residual current device. It must be combined with suitable overcurrent protection, as it does not include overload or short-circuit protection.