IID Differential 2P 63A 300mA AC Class Selective with reference A9R15263 from the brand SCHNEIDER ELECTRIC
IID Differential 2P 63A 300mA AC Class Selective with reference A9R15263 from the brand SCHNEIDER ELECTRIC
SCHNEIDER ELECTRIC

IID Differential 2P 63A 300mA AC Class Selective

REF
A9R15263
(0)
Free shipping
192.99 €
€192.99
€1,214.10
Up to -8% for professionals. Discover it.
Schneider Electric Acti9 iID 2P 63 A residual current circuit breaker, 300 mA, selective type AC, 230-240 V, with independent voltage trip and DIN rail mounting.
Buy now and receive it between 20 and November 23
Express free delivery
Get +193 +386 Sumis for the purchase
Receive 2x Sumis for a limited time
More about the product

Information about IID Differential 2P 63A 300mA AC Class Selective

The Schneider Electric A9R15263 is a residual current circuit breaker from the Acti9 iID range designed to detect earth leakage currents and automatically disconnect the circuit when the set threshold is exceeded. It features 2 poles, a rated current of 63 A, residual current sensitivity of 300 mA, type AC protection and selective operation, making it especially suitable as a main RCD or upstream of other residual current devices in low-voltage electrical installations.

Its selective tripping incorporates an intentional time delay that allows the device to coordinate with RCDs located downstream, ensuring that in the event of a localized leakage, the protection closest to the fault operates first. The A9R15263 operates at a rated voltage of 220-240 V AC and 50/60 Hz, uses voltage-independent residual current tripping technology and is easily installed on a 35 mm DIN rail.

Main features of the Schneider Electric A9R15263

  • Schneider Electric RCCB residual current circuit breaker.
  • Range: Acti9 iID.
  • Reference: A9R15263.
  • Number of poles: 2P.
  • Rated current In: 63 A.
  • Residual current sensitivity IΔn: 300 mA.
  • Differential protection class: type AC.
  • Tripping type: selective.
  • Rated operational voltage: 220-240 V AC.
  • Network frequency: 50/60 Hz.
  • Voltage-independent residual current tripping technology.
  • Neutral on the left.
  • Rated making and breaking capacity Im: 1,500 A.
  • Differential making and breaking capacity Idm: 1,500 A.
  • Conditional short-circuit current: 10 kA.
  • Rated insulation voltage Ui: 500 V.
  • Rated impulse withstand voltage Uimp: 6 kV.
  • Suitable for isolation according to EN/IEC 61008-1.
  • Contact position indicator.
  • Lever operation.
  • Clip-on mounting on 35 mm DIN rail.
  • Width: 36 mm.
  • Terminal protection rating: IP20.

Selective 300 mA residual current protection

The A9R15263 has a residual current sensitivity of 300 mA and selective tripping. This means the device introduces a controlled delay before tripping, allowing it to coordinate with residual current devices installed downstream.

In an installation with several levels of residual current protection, this selectivity helps limit disconnection to the part of the installation where the fault is located. If a leakage can be cleared by a downstream RCD, the selective device upstream remains connected as long as the intended coordination conditions are maintained.

This feature is especially useful in main distribution boards, sub-distribution boards and other installations where service continuity needs to be improved by avoiding unnecessary disconnection of unaffected circuits.

Type AC RCD

The Schneider Electric A9R15263 belongs to class AC. It is designed to detect sinusoidal alternating residual currents, in accordance with the characteristics defined for this type of residual current circuit breaker.

The choice between type AC, A, A-SI or other classes should be made according to the connected loads, the nature of possible leakage currents and the regulations applicable to the installation.

63 A rated current

The device supports a rated current of 63 A. This current indicates the intensity that the residual current circuit breaker can carry continuously under the conditions specified by the manufacturer.

The RCD does not itself provide thermal-magnetic protection against overloads or short circuits. For this reason, it must be coordinated with the corresponding overcurrent protection devices, such as miniature circuit breakers or properly sized fuses.

Operating voltage of 220-240 V AC

The A9R15263 is designed for 220-240 V AC networks at 50/60 Hz. Its two-pole configuration allows simultaneous disconnection of phase and neutral in compatible single-phase installations.

Electrical characteristic Value Rated current In 63 A Residual current sensitivity IΔn 300 mA Differential class Type AC Differential tripping Selective Number of poles 2P Rated operational voltage Ue 220-240 V AC Frequency 50/60 Hz Insulation voltage Ui 500 V AC Rated impulse withstand voltage Uimp 6 kV

Voltage-independent tripping

The residual current tripping technology of the Acti9 iID is voltage-independent. Detection and tripping in the event of a residual current do not depend on an external auxiliary electronic supply, which is characteristic of this type of electromechanical RCCB.

This design allows the main residual current function to remain available in accordance with the conditions specified by the standard and the manufacturer.

Making and breaking capacity

Schneider Electric specifies for the A9R15263 a rated making and breaking capacity Im of 1,500 A and a differential making and breaking capacity Idm also of 1,500 A.

The rated conditional short-circuit current reaches 10 kA when the RCD is correctly coordinated with the short-circuit protection device established for the installation.

Parameter Value Rated making and breaking capacity Im 1,500 A Differential making and breaking capacity Idm 1,500 A Conditional short-circuit current 10 kA 8/20 µs impulse withstand current 3 kA

Coordination with downstream RCDs

One of the main applications of the A9R15263 is coordination with other residual current devices installed at lower levels of the distribution system. Schneider Electric specifically indicates that the selective model is designed to ensure selectivity with downstream residual current devices.

This architecture can be used, for example, by installing a selective 300 mA RCD as general protection and higher-sensitivity devices on final circuits when required by the electrical design.

To achieve effective selectivity, the sensitivities, tripping times and coordination schemes established by Schneider Electric and the applicable electrical regulations must be respected.

Protection against indirect contact and fire risk

The Acti9 iID contributes to protection against indirect electric contact by disconnecting the circuit when an earth leakage above the operating threshold occurs.

Its 300 mA sensitivity also makes it suitable for use in installation protection strategies against fire risk caused by certain leakage currents, always in accordance with the installation design and applicable regulatory requirements.

Due to its 300 mA sensitivity, this device should not be confused with a high-sensitivity 30 mA RCD intended for applications where additional personal protection is required.

Suitable for isolation

The Schneider Electric A9R15263 is suitable for isolation according to EN/IEC 61008-1. It can therefore participate in the electrical isolation of the circuit within the conditions specified by the manufacturer.

The device also includes contact position indication to facilitate visual identification of its state during inspection and maintenance operations.

DIN rail installation

The residual current device is installed by clip-on mounting on a 35 mm DIN rail, allowing integration alongside MCBs and other modular devices in the Acti9 range.

Its width is 36 mm, equivalent to four 9 mm modules or two standard 18 mm modules, so it takes up little space inside the electrical panel.

Conductor connection

The upper and lower terminals accept rigid and flexible conductors and allow supply from either side depending on the panel configuration.

Conductor type Accepted cross-section Rigid conductor 1 to 35 mm² Flexible conductor 1 to 25 mm² Flexible conductor with ferrule 1 to 25 mm² Strip length 14 mm Tightening torque 3.5 Nm

Durability

The Schneider Electric A9R15263 is designed to offer a long service life in electrical distribution applications. The manufacturer specifies a mechanical endurance of 20,000 cycles and an electrical endurance of up to 15,000 cycles under the indicated conditions.

Feature Value Mechanical endurance 20,000 cycles Electrical endurance 15,000 cycles

Environmental conditions

The residual current circuit breaker is designed to operate in residential, commercial and tertiary electrical panels within the environmental conditions specified by Schneider Electric.

Environmental feature Value Terminal protection rating IP20 Operating ambient temperature -5 to +60 °C Storage temperature -40 to +85 °C Pollution degree 3

Recommended applications

The Schneider Electric Acti9 iID A9R15263 is especially suitable for installations that require selective 300 mA residual current protection and coordination with higher-sensitivity devices installed downstream.

  • Main distribution boards.
  • Sub-distribution boards.
  • Residential installations.
  • Commercial premises.
  • Tertiary buildings.
  • Installations with several levels of residual current protection.
  • Single-phase circuits up to 63 A compatible with its rated voltage.
  • Protection of installations against certain earth leakage currents.

Standards

The A9R15263 is designed in accordance with EN/IEC 61008-1, the standard applicable to residual current operated circuit breakers without integral overcurrent protection for household and similar uses.

As an RCCB, its function is residual current protection. It does not include thermal-magnetic tripping against overloads or short circuits, so it must be used together with the appropriate overcurrent protection for the circuit.

Technical summary of the Schneider Electric A9R15263

Feature Specification Brand Schneider Electric Range Acti9 iID Reference A9R15263 Type RCCB residual current circuit breaker Poles 2P Neutral position Left Rated current 63 A Residual current sensitivity 300 mA Class Type AC Time delay Selective Rated voltage 220-240 V AC Frequency 50/60 Hz Differential tripping Voltage-independent Im / Idm 1,500 A / 1,500 A Conditional short-circuit current 10 kA Insulation voltage Ui 500 V Rated impulse withstand voltage Uimp 6 kV Mounting 35 mm DIN rail Width 36 mm Protection rating IP20 Standard EN/IEC 61008-1 EAN 3606480089176

The Schneider Electric A9R15263 Acti9 iID offers a 63 A, 300 mA two-pole residual current solution especially suited to installations that require selectivity between different protection levels. Its type AC classification, voltage-independent tripping, 10 kA conditional short-circuit current and modular DIN rail mounting make it easy to integrate into residential and tertiary electrical panels.

Specifications
Manufacturer
SCHNEIDER ELECTRIC
Reference
A9R15263
SKU
SCH0AB0B772
Object
Residual current switch
Tension
230 V AC 50/60 Hz compliant with EN 61008-1. 230/240 V AC 50/60 Hz compliant with IEC 61008-1 V
Number of poles
2P
Assembly
Fixed on DIN rail
Nominal current
63 A
Network type
CA
Protection rating
IP20
Datasheets
Reviews
Returns within 30 days
Shop with peace of mind. If something goes wrong, we'll take care of it.
After-sales service
Any questions? Our support team will be happy to help you.
Pay how and when you want
Card, bank transfer, PayPal... Installment? We have them all.
GroupSumi is your online distributor for construction, electrical material and climate control.
All rights reserved © 2026 GroupSumi