TeSys Differential 2P 3A with reference GB2CD08 from the brand SCHNEIDER ELECTRIC
TeSys Differential 2P 3A with reference GB2CD08 from the brand SCHNEIDER ELECTRIC
SCHNEIDER ELECTRIC

TeSys Differential 2P 3A

REF
GB2CD08
(0)
46.00 €
€46.00
€145.03
Up to -6% for professionals. Discover it.
Schneider Electric TeSys GB2CD08 1P+N 3 A thermal-magnetic circuit breaker for control circuits, with magnetic trip at 40 A, 3 kA breaking capacity, and DIN rail mounting.
Buy now and receive it between 20 and November 23
Express delivery
Get +46 +92 Sumis for the purchase
Receive 2x Sumis for a limited time
More about the product

Information about TeSys Differential 2P 3A

The Schneider Electric TeSys GB2CD08 is a thermal-magnetic circuit breaker specifically designed for the protection of control and command circuits against overloads and short circuits. It features a 1P+N configuration, with one protected pole and the neutral disconnected simultaneously, a rated current of 3 A, and a magnetic trip current of 40 A.

This miniature circuit breaker belongs to Schneider Electric’s TeSys GB2 range and can operate on both AC and DC networks. It offers an Icu breaking capacity of 3 kA at 230/240 V AC in accordance with IEC 60947-2 and has an especially compact width of just 15 mm, designed to save space in automation and machinery electrical panels.

1P+N 3 A circuit breaker for control circuits

The GB2CD08 reference includes one thermally and magnetically protected pole plus one neutral pole that disconnects simultaneously. Therefore, although it physically interrupts two conductors, it should not be confused with a conventional two-pole circuit breaker with two protected poles or with a residual current device.

Its rated current of 3 A makes it especially suitable for low-power auxiliary and control circuits used in machinery and automation systems.

Thermal and magnetic protection

The TeSys GB2CD08 combines two protection systems:

  • Thermal protection: acts against sustained overloads that could cause excessive heating of wiring or equipment.
  • Magnetic protection: provides rapid disconnection in the event of high currents caused by a short circuit.

Schneider Electric specifies a magnetic trip current of 40 A, approximately equivalent to 13 times the device’s rated current.

3 kA breaking capacity

In accordance with IEC 60947-2, the GB2CD08 has a ultimate breaking capacity Icu of 3 kA at 230/240 V AC. The service breaking capacity Ics is 50% of Icu under these conditions.

This capacity is suited to its main function as a protection device for auxiliary and control circuits within machinery and automation electrical panels.

Compatible with AC and DC

The Schneider Electric GB2CD08 can be used on AC and DC networks within the values specified by the manufacturer.

  • Rated operational voltage: up to 250 V AC at 50/60 Hz according to IEC 60947-2.
  • Voltage according to UL/CSA: up to 277 V AC at 60 Hz.
  • DC operating voltage: up to 48 V DC.
  • Frequency: 50/60 Hz.

This compatibility makes it suitable for a wide variety of industrial auxiliary circuits.

Applications in automation and machinery

The TeSys GB2 is mainly developed for the protection of control circuits. It can be used in electrical panels associated with machinery and automated installations to protect elements such as:

  • Command and control circuits.
  • Contactor and relay coils.
  • Solenoid valves.
  • Electric brakes.
  • Transformers and auxiliary power supplies.
  • Industrial automation systems.
  • Other auxiliary loads compatible with its rated current.

Compact DIN rail mounting

The GB2CD08 is designed for clip-on mounting on a 35 mm symmetrical DIN rail. It can also be installed on a compatible plate, providing flexibility during panel design.

Its width of only 15 mm makes it possible to make the most of available space and is especially useful in panels with a high density of control devices.

  • Height: 74 mm.
  • Width: 15 mm.
  • Depth: 67 mm.
  • Net weight: approximately 0.07 kg.
  • Modular width: 2 x 9 mm steps.

Screw terminal connection

The circuit breaker accepts different conductor types and cross-sections through its connection terminals:

  • 1 rigid conductor: 0.75-6 mm².
  • 2 rigid conductors: 0.75-4 mm².
  • 1 flexible conductor with ferrule: 0.75-4 mm².
  • 2 flexible conductors with ferrule: 0.75-2.5 mm².
  • Tightening torque: 1.2 Nm.

Durability for professional panels

Schneider Electric specifies a mechanical durability of 8,000 cycles and an electrical durability of 8,000 cycles, offering performance suitable for professional control and automation applications.

The power loss indicated by the manufacturer is approximately 2 W per pole.

IP20 protection and environmental conditions

The TeSys GB2CD08 has an IP20 protection rating according to IEC 60529, so it is intended to be installed inside a panel or enclosure that provides the level of protection required by the installation.

  • Operating temperature: -20 to 60 °C.
  • Storage temperature: -40 to 80 °C.
  • Maximum operating altitude: 3000 m.
  • Fire resistance: 960 °C according to IEC 60695-2-1.
  • Impulse withstand voltage Uimp: 4 kV.

Technical characteristics of the Schneider Electric GB2CD08

  • Brand: Schneider Electric.
  • Reference: GB2CD08.
  • Range: TeSys.
  • Product: TeSys GB2.
  • Type: thermal-magnetic circuit breaker.
  • Application: control circuit protection.
  • Configuration: 1P+N.
  • Protected poles: 1.
  • Neutral disconnected simultaneously: yes.
  • Rated current: 3 A.
  • Trip technology: thermal-magnetic.
  • Magnetic trip current: 40 A.
  • Network type: AC/DC.
  • IEC rated voltage: up to 250 V AC.
  • DC voltage: up to 48 V DC.
  • Frequency: 50/60 Hz.
  • Breaking capacity Icu: 3 kA at 230/240 V AC.
  • Service breaking capacity Ics: 50% of Icu at 230/240 V AC.
  • Utilization category: A according to IEC 60947-2.
  • DC categories: DC-12 and DC-13.
  • Impulse withstand voltage Uimp: 4 kV.
  • Mounting: 35 mm DIN rail or plate.
  • Mounting position: vertical or horizontal.
  • Operation: front lever.
  • Width: 15 mm.
  • Height: 74 mm.
  • Depth: 67 mm.
  • Weight: approximately 0.07 kg.
  • Protection rating: IP20.
  • Mechanical durability: 8,000 cycles.
  • Electrical durability: 8,000 cycles.
  • Operating temperature: -20 to 60 °C.
  • Maximum altitude: 3000 m.
  • Standards: EN/IEC 60947-1 and EN/IEC 60947-2.
  • EAN: 3389110214741.

Compact protection for auxiliary circuits

The Schneider Electric GB2CD08 provides thermal and magnetic protection for 3 A auxiliary circuits while occupying only 15 mm of panel width. Its 1P+N configuration allows phase and neutral to be disconnected simultaneously, while maintaining thermal-magnetic protection on the phase conductor.

Its combination of 3 A, 40 A magnetic trip, 3 kA breaking capacity, AC/DC compatibility, and DIN rail mounting makes it an especially suitable solution for automation panels, machinery, and professional control circuits.

Important: the GB2CD08 does not provide residual current protection against earth leakage. For this function, a suitable residual current device must be installed according to the characteristics of the installation.

Specifications
Manufacturer
SCHNEIDER ELECTRIC
Reference
GB2CD08
SKU
SCH2DB7D230
Object
Circuit breaker
Number of poles
2P, 1P+N
Assembly
For clips. Horizontal/ Vertical
Nominal current
3 A
Network type
CA, CC
Protection rating
IP20
Intensity
3 A
Datasheets
Reviews
Returns within 30 days
Shop with peace of mind. If something goes wrong, we'll take care of it.
After-sales service
Any questions? Our support team will be happy to help you.
Pay how and when you want
Card, bank transfer, PayPal... Installment? We have them all.
GroupSumi is your online distributor for construction, electrical material and climate control.
All rights reserved © 2026 GroupSumi