Schneider Electric TeSys GV2ME07 thermal magnetic motor circuit breaker, 3P, adjustable from 1.6 to 2.5 A, for motors up to 0.75 kW at 400/415 V, 100 kA, and push-button control.
Buy now and receive it between 20 and November 23
Express delivery
Get +88 +175 Sumis for the purchase
Receive 2x Sumis for a limited time
More about the product

Information about Thermal Magnetic Circuit Breaker 1.6-2.5A 50-60HZ

The Schneider Electric GV2ME07 is a motor circuit breaker or thermal-magnetic circuit breaker from the TeSys GV2 / TeSys Deca range, specifically designed for the protection and manual control of electric motors. It features 3 poles, a thermal adjustment range of 1.6 to 2.5 A and magnetic short-circuit protection, combining overload, short-circuit and phase-loss protection in a single device.

With a reference motor power of up to 0.75 kW at 400/415 V AC and a high breaking capacity of up to 100 kA at 400/415 V, the GV2ME07 is a compact solution for automation panels, machinery, pumps, fans and other three-phase motor applications. Its START/STOP pushbutton operation also makes manual circuit control easy.

Key features of the Schneider Electric GV2ME07

  • Motor circuit breaker or thermal-magnetic circuit breaker for motor protection.
  • Brand: Schneider Electric.
  • Range: TeSys GV2 / TeSys Deca.
  • Reference: GV2ME07.
  • Number of poles: 3P.
  • Thermal protection adjustment range: 1.6 to 2.5 A.
  • Maximum rated current: 2.5 A.
  • Trip technology: thermal-magnetic.
  • Overload protection.
  • Magnetic short-circuit protection.
  • Phase-loss sensitivity.
  • Network frequency: 50/60 Hz.
  • Rated operational voltage: up to 690 V AC.
  • Reference motor power: 0.75 kW at 400/415 V.
  • Breaking capacity Icu: up to 100 kA at 400/415 V.
  • Utilization category AC-3 according to IEC 60947-4-1.
  • Category A according to IEC 60947-2.
  • Pushbutton operation.
  • Connection via screw terminals.
  • Suitable for isolation.
  • Installation on DIN rail or plate using the corresponding accessories.
  • IP20 protection rating.

Adjustable thermal protection between 1.6 and 2.5 A

The GV2ME07 incorporates adjustable thermal protection between 1.6 and 2.5 A. This setting allows the device to be adapted to the rated current of the motor to be protected.

In the event of a sustained overload, the thermal mechanism opens the circuit to prevent excessive current over a prolonged period from causing harmful overheating of the motor and its conductors.

The setting must be made according to the rated current shown on the motor nameplate and taking into account the actual installation conditions.

Magnetic short-circuit protection

In addition to thermal protection, the Schneider Electric GV2ME07 includes a fast-acting magnetic trip unit. This function opens the circuit when a high short-circuit current occurs.

The combination of thermal and magnetic protection allows the GV2ME07 to be used as a dedicated motor protection device, avoiding the need for a separate thermal overload relay when the application characteristics are compatible.

Phase-loss sensitivity

The motor circuit breaker has phase-loss sensitivity. This feature is especially important in three-phase motors, as the loss of one phase can cause severe current imbalance and excessive heating of the windings.

Protection against this condition helps reduce the risk of motor damage when anomalies occur in the three-phase supply.

Reference motor power

The permissible power depends on the motor supply voltage. Schneider Electric specifies the following reference powers for the GV2ME07:

Network voltage Motor power 400/415 V AC 0.75 kW 500 V AC 1.1 kW 690 V AC 1.5 kW

The final selection of the motor circuit breaker should be made primarily according to the motor rated current, ensuring that it falls within the adjustable range of 1.6 to 2.5 A.

High breaking capacity

The GV2ME07 offers a high interrupting capacity against short circuits. Schneider Electric specifies a rated ultimate short-circuit breaking capacity Icu of 100 kA at 230/240 V, 400/415 V, 440 V and 500 V AC, in accordance with IEC 60947-2.

Voltage Breaking capacity Icu 230/240 V AC 100 kA 400/415 V AC 100 kA 440 V AC 100 kA 500 V AC 100 kA 690 V AC 3 kA

At 400/415 V, its high breaking capacity makes it suitable for use in electrical panels with significant short-circuit levels, provided the rest of the installation is correctly sized and coordinated.

Control via START and STOP pushbuttons

The Schneider Electric GV2ME07 uses a pushbutton operating mechanism. This design allows manual switching on and off of the power circuit.

The ability to use the motor circuit breaker both as a protection device and for manual control simplifies the construction of certain control panels and small motor starters.

Electrical characteristics

Characteristic Value Device type Thermal-magnetic motor circuit breaker Number of poles 3P Thermal adjustment range 1.6 to 2.5 A Maximum rated current 2.5 A Trip technology Thermal-magnetic Network type AC Frequency 50/60 Hz Rated operational voltage Up to 690 V AC Rated insulation voltage Ui 690 V AC Impulse withstand voltage Uimp 6 kV Utilization category AC-3 Category according to IEC 60947-2 A Phase-loss sensitive Yes

Connection via screw terminals

The GV2ME07 uses screw terminals for power circuit connections. This system provides a compact connection suitable for industrial and automation electrical panels.

The tightening torque and conductor cross-sections used must always comply with the instructions included in Schneider Electric’s technical and installation documentation.

DIN rail installation

The motor circuit breaker can be installed on a DIN rail using a clip, making it easy to integrate into electrical panels alongside contactors, relays, power supplies and other automation components.

It can also be mounted on a plate using the corresponding fixing elements, providing flexibility for different panel designs.

Compact dimensions

Characteristic Value Width 45 mm Height 89 mm Depth Approx. 78.2 mm Approximate weight 0.26 kg Protection rating IP20

Its width of just 45 mm makes it possible to build compact motor starters and use the available space in the electrical panel efficiently.

Durability

Schneider Electric specifies high durability for the GV2 range. The GV2ME07 achieves up to 100,000 mechanical operating cycles and up to 100,000 electrical operating cycles in AC-3 category at 440 V under the manufacturer’s defined conditions.

Environmental conditions

Characteristic Value Protection rating IP20 Operating ambient temperature -20 to +60 °C Storage temperature -40 to +80 °C Maximum operating altitude 2,000 m

Combination with TeSys contactors

The GV2ME07 can be combined with Schneider Electric TeSys contactors to form a complete motor starting and protection assembly. Schneider offers different connection blocks and accessories to facilitate the electrical and mechanical coupling between devices.

In these configurations, the motor circuit breaker provides overload and short-circuit protection, while the contactor enables frequent switching operations or motor control via an external control circuit.

Recommended applications

The Schneider Electric GV2ME07 is especially suitable for protecting three-phase motors with a rated current between 1.6 and 2.5 A.

  • Water pumps.
  • Fans and extractors.
  • Small compressors.
  • HVAC systems.
  • Conveyor belts.
  • Industrial machinery.
  • Water treatment equipment.
  • Automation electrical panels.
  • Small motor starters.

Important: the GV2ME07 is a thermal-magnetic motor circuit breaker. It protects against overloads, short circuits and phase loss, but does not include residual current protection against earth leakage currents. When the installation requires residual current protection, the corresponding device must be installed.

Standards and certifications

The Schneider Electric GV2ME07 is designed in accordance with IEC/EN 60947-2 and IEC/EN 60947-4-1. The range also has international certifications such as UL, CSA, CCC, EAC and marine application certifications, among others, according to Schneider Electric documentation.

Technical summary of the Schneider Electric GV2ME07

Characteristic Specification Brand Schneider Electric Range TeSys GV2 / TeSys Deca Reference GV2ME07 Type Thermal-magnetic motor circuit breaker Application Motor protection Number of poles 3P Thermal range 1.6 to 2.5 A Maximum rated current 2.5 A Motor power at 400/415 V 0.75 kW Breaking capacity Icu at 400/415 V 100 kA Maximum operational voltage 690 V AC Frequency 50/60 Hz Control Pushbuttons Connection Screw terminals Phase-loss sensitive Yes Protection rating IP20 Dimensions Approx. 89 x 45 x 78.2 mm Weight Approx. 0.26 kg EAN 3389110343076

The Schneider Electric TeSys GV2ME07 combines thermal-magnetic protection, 1.6 to 2.5 A adjustment, phase-loss sensitivity and high breaking capacity in a compact 45 mm-wide format. It is an especially suitable solution for protecting and controlling three-phase motors up to 0.75 kW at 400/415 V in professional electrical panels.

Specifications
Manufacturer
SCHNEIDER ELECTRIC
Reference
GV2ME07
SKU
SCH0D81CB0B
Object
Circuit breaker
Number of poles
Assembly
For clips. Horizontal/ Vertical
Network type
CA
Protection rating
IP20
Warranty
18 months
Operating temperature
-20.00 - 60.00 °C
Datasheets
Reviews
Returns within 30 days
Shop with peace of mind. If something goes wrong, we'll take care of it.
After-sales service
Any questions? Our support team will be happy to help you.
Pay how and when you want
Card, bank transfer, PayPal... Installment? We have them all.
GroupSumi is your online distributor for construction, electrical material and climate control.
All rights reserved © 2026 GroupSumi