The Schneider Electric Acti9 C120N A9N18376 thermal-magnetic circuit breaker is a modular automatic switch with 4 poles, 125 A and C curve, designed to protect low-voltage electrical circuits against overloads and short circuits. It features 4 protected poles using thermal-magnetic technology and offers a breaking capacity of 10 kA, making it an especially suitable solution for high-current distribution boards.
It is part of Schneider Electric’s Acti9 C120 range and combines protection, control and isolation functions. Its design allows installation on a 35 mm DIN rail, supports signaling and trip auxiliaries, and can be complemented with residual current protection via a compatible Vigi block.
The A9N18376 has four protected poles, meaning it integrates thermal-magnetic protection in all connected conductors. This configuration allows simultaneous opening of all poles in the event of an overload, short circuit or manual switching operation.
Its 125 A rated current makes it a suitable solution for power distribution boards and lines where a high-current modular circuit breaker is required.
This reference uses a C tripping curve. Schneider Electric specifies a magnetic tripping threshold of approximately 5 to 10 times the rated current.
This feature allows it to withstand certain transient inrush currents without nuisance tripping, while still maintaining short-circuit protection. The C curve is commonly used in general distribution circuits and loads with moderate starting currents.
According to IEC/EN 60898-1, the Acti9 C120N A9N18376 has a rated breaking capacity Icn of 10,000 A between 230 and 400 V AC.
In accordance with IEC/EN 60947-2, Schneider Electric specifies the following ultimate breaking capacity values Icu:
The breaking capacity must be equal to or greater than the prospective short-circuit current at the installation point.
The circuit breaker has limitation class 3. This current-limiting capability helps reduce the energy flowing through the circuit during a short circuit and decreases the thermal and electrodynamic stresses on downstream conductors and equipment.
Schneider Electric specifies this C120N as suitable for isolation according to IEC/EN 60947-2. The device includes a visual indication of contact status and a green strip that confirms the physical opening of the circuit when the breaker is correctly open.
This feature facilitates maintenance and circuit isolation operations inside professional electrical panels.
The A9N18376 uses a thermal-magnetic tripping unit. The thermal element protects against sustained overloads, while the magnetic trip acts quickly when a high short-circuit current occurs.
In this way, the device protects both conductors and connected equipment against the main risks caused by overcurrent.
The circuit breaker is installed by clip-on mounting on a 35 mm symmetrical DIN rail. Its width corresponds to 12 modules of 9 mm, equivalent to 108 mm.
Schneider Electric also indicates compatibility with comb busbar systems and suitable distribution blocks, making it easier to integrate the breaker within Acti9 panels.
The C120 range allows the breaker to be complemented with different accessories to expand its functions:
This makes it possible to integrate the A9N18376 into panels that require additional supervision, remote control or residual current protection functions.
The circuit breaker uses tunnel terminals capable of accepting large conductor cross-sections:
The final conductor size must be calculated according to the design current, installation method, temperature, voltage drop and applicable electrical regulations.
Its modular format makes it possible to integrate four-pole 125 A protection into distribution electrical panels while maintaining the standard DIN rail architecture.
Schneider Electric specifies a mechanical durability of up to 20,000 cycles and an electrical durability of up to 5,000 cycles according to IEC 60947-2.
These performance levels make the breaker suitable for professional installations where reliability is required over a high number of operations.
The Acti9 C120N is designed to operate within a wide temperature range:
The device has an IP20 protection rating at its terminals according to IEC/EN 60529. It must be installed inside an enclosure or cabinet that provides the appropriate protection rating for the operating environment.
Due to its four-pole configuration and high rated current, the A9N18376 is suitable for applications such as:
The Schneider Electric A9N18376 combines a 125 A rated current, four protected poles, C curve and a 10 kA breaking capacity in a modular device designed for professional electrical panels. Its thermal-magnetic tripping unit protects against overloads and short circuits, while its suitability for isolation makes maintenance and disconnection tasks easier.
Compatibility with auxiliaries, remote monitoring and Vigi residual current blocks expands integration possibilities within the Acti9 ecosystem. To ensure proper protection, selection should be based on the circuit design current, conductor cross-section, prospective short-circuit current and actual installation conditions.