C120N Circuit Breaker 4P 125A Curve C 10kA with reference A9N18376 from the brand SCHNEIDER ELECTRIC
C120N Circuit Breaker 4P 125A Curve C 10kA with reference A9N18376 from the brand SCHNEIDER ELECTRIC
SCHNEIDER ELECTRIC

C120N Circuit Breaker 4P 125A Curve C 10kA

REF
A9N18376
(0)
Free shipping
498.00 €
€498.00
€1,300.00
Up to -6% for professionals. Discover it.
Schneider Electric Acti9 C120N 4P 125A C-curve thermal magnetic circuit breaker, 10 kA breaking capacity, 4 protected poles, DIN rail mounting, VisiSafe and suitable for industrial isolation.
Buy now and receive it between 20 and November 23
Express free delivery
Get +498 +996 Sumis for the purchase
Receive 2x Sumis for a limited time
More about the product

Information about C120N Circuit Breaker 4P 125A Curve C 10kA

The Schneider Electric Acti9 C120N A9N18376 thermal-magnetic circuit breaker is a modular automatic switch with 4 poles, 125 A and C curve, designed to protect low-voltage electrical circuits against overloads and short circuits. It features 4 protected poles using thermal-magnetic technology and offers a breaking capacity of 10 kA, making it an especially suitable solution for high-current distribution boards.

It is part of Schneider Electric’s Acti9 C120 range and combines protection, control and isolation functions. Its design allows installation on a 35 mm DIN rail, supports signaling and trip auxiliaries, and can be complemented with residual current protection via a compatible Vigi block.

Main features of the Schneider Electric A9N18376

  • Brand: Schneider Electric.
  • Range: Acti9.
  • Series: C120.
  • Model: C120N.
  • Reference: A9N18376.
  • Type: modular thermal-magnetic circuit breaker.
  • Number of poles: 4P.
  • Protected poles: 4.
  • Rated current: 125 A at 30 °C.
  • Tripping curve: C.
  • Tripping technology: thermal-magnetic.
  • Frequency: 50/60 Hz.
  • Breaking capacity Icn: 10 kA at 230-400 V AC according to IEC/EN 60898-1.
  • Breaking capacity Icu: 10 kA at 380-415 V AC according to IEC/EN 60947-2.
  • Breaking capacity Icu: 20 kA at 220-240 V AC according to IEC/EN 60947-2.
  • Rated operational voltage: 380-415 V AC.
  • Insulation voltage Ui: 500 V.
  • Impulse withstand voltage Uimp: 6 kV.
  • Limitation class: 3.
  • Overvoltage category: IV.
  • Pollution degree: 3.
  • Suitable for isolation: yes.
  • Mounting: 35 mm symmetrical DIN rail.
  • Width: 108 mm.
  • Height: 81 mm.
  • Depth: 73 mm.
  • Net weight: 0.82 kg.

125 A four-pole protection

The A9N18376 has four protected poles, meaning it integrates thermal-magnetic protection in all connected conductors. This configuration allows simultaneous opening of all poles in the event of an overload, short circuit or manual switching operation.

Its 125 A rated current makes it a suitable solution for power distribution boards and lines where a high-current modular circuit breaker is required.

C curve

This reference uses a C tripping curve. Schneider Electric specifies a magnetic tripping threshold of approximately 5 to 10 times the rated current.

This feature allows it to withstand certain transient inrush currents without nuisance tripping, while still maintaining short-circuit protection. The C curve is commonly used in general distribution circuits and loads with moderate starting currents.

10 kA breaking capacity

According to IEC/EN 60898-1, the Acti9 C120N A9N18376 has a rated breaking capacity Icn of 10,000 A between 230 and 400 V AC.

In accordance with IEC/EN 60947-2, Schneider Electric specifies the following ultimate breaking capacity values Icu:

  • 220-240 V AC: 20 kA.
  • 380-415 V AC: 10 kA.
  • 440 V AC: 6 kA.
  • Up to 500 V DC: 10 kA according to the connection conditions indicated by the manufacturer.

The breaking capacity must be equal to or greater than the prospective short-circuit current at the installation point.

Limitation class 3

The circuit breaker has limitation class 3. This current-limiting capability helps reduce the energy flowing through the circuit during a short circuit and decreases the thermal and electrodynamic stresses on downstream conductors and equipment.

Suitable for isolation

Schneider Electric specifies this C120N as suitable for isolation according to IEC/EN 60947-2. The device includes a visual indication of contact status and a green strip that confirms the physical opening of the circuit when the breaker is correctly open.

This feature facilitates maintenance and circuit isolation operations inside professional electrical panels.

Protection against overloads and short circuits

The A9N18376 uses a thermal-magnetic tripping unit. The thermal element protects against sustained overloads, while the magnetic trip acts quickly when a high short-circuit current occurs.

In this way, the device protects both conductors and connected equipment against the main risks caused by overcurrent.

DIN rail mounting

The circuit breaker is installed by clip-on mounting on a 35 mm symmetrical DIN rail. Its width corresponds to 12 modules of 9 mm, equivalent to 108 mm.

Schneider Electric also indicates compatibility with comb busbar systems and suitable distribution blocks, making it easier to integrate the breaker within Acti9 panels.

Compatible with auxiliaries and Vigi residual current protection

The C120 range allows the breaker to be complemented with different accessories to expand its functions:

  • Signaling auxiliary contacts.
  • Trip auxiliaries.
  • Remote monitoring systems.
  • Control accessories.
  • Compatible Vigi residual current blocks.

This makes it possible to integrate the A9N18376 into panels that require additional supervision, remote control or residual current protection functions.

Conductor connection

The circuit breaker uses tunnel terminals capable of accepting large conductor cross-sections:

  • Rigid conductor: 1 to 50 mm².
  • Flexible conductor: 1.5 to 35 mm².
  • Strip length: 15 mm.
  • Tightening torque: 3.5 Nm.

The final conductor size must be calculated according to the design current, installation method, temperature, voltage drop and applicable electrical regulations.

Dimensions and weight

  • Width: 108 mm.
  • Height: 81 mm.
  • Depth: 73 mm.
  • Net weight: 0.82 kg.
  • Color: white RAL 9003.

Its modular format makes it possible to integrate four-pole 125 A protection into distribution electrical panels while maintaining the standard DIN rail architecture.

High durability

Schneider Electric specifies a mechanical durability of up to 20,000 cycles and an electrical durability of up to 5,000 cycles according to IEC 60947-2.

These performance levels make the breaker suitable for professional installations where reliability is required over a high number of operations.

Environmental conditions

The Acti9 C120N is designed to operate within a wide temperature range:

  • Operating temperature: -25 to 70 °C.
  • Storage temperature: -40 to 85 °C.
  • Pollution degree: 3.
  • Overvoltage category: IV.

IP20 protection rating

The device has an IP20 protection rating at its terminals according to IEC/EN 60529. It must be installed inside an enclosure or cabinet that provides the appropriate protection rating for the operating environment.

Applications of the Schneider Electric C120N 125 A

Due to its four-pole configuration and high rated current, the A9N18376 is suitable for applications such as:

  • Main and secondary low-voltage distribution boards.
  • Three-phase lines with neutral.
  • Industrial electrical distribution.
  • Commercial installations.
  • HVAC and machinery panels.
  • Protection of high-current lines.
  • Installations requiring a 10 kA breaking capacity.

Technical data of the Schneider Electric A9N18376

  • Manufacturer: Schneider Electric.
  • Reference: A9N18376.
  • EAN: 3606480379475.
  • Range: Acti9.
  • Series: C120.
  • Model: C120N.
  • Type: thermal-magnetic circuit breaker.
  • Application: electrical distribution.
  • Poles: 4P.
  • Protected poles: 4.
  • Rated current: 125 A at 30 °C.
  • Curve: C.
  • Tripping technology: thermal-magnetic.
  • Magnetic threshold: 5-10 x In.
  • Frequency: 50/60 Hz.
  • Icn: 10 kA at 230-400 V AC according to IEC/EN 60898-1.
  • Icu at 220-240 V: 20 kA.
  • Icu at 380-415 V: 10 kA.
  • Icu at 440 V: 6 kA.
  • Rated operational voltage: 380-415 V AC.
  • Ui: 500 V.
  • Uimp: 6 kV.
  • Limitation class: 3.
  • Overvoltage category: IV.
  • Pollution degree: 3.
  • Suitable for isolation: yes.
  • Position indication: yes.
  • Mounting: 35 mm symmetrical DIN rail.
  • Width: 108 mm.
  • Height: 81 mm.
  • Depth: 73 mm.
  • Weight: 0.82 kg.
  • Color: white RAL 9003.
  • Protection rating: IP20.
  • Mechanical durability: 20,000 cycles.
  • Electrical durability: 5,000 cycles.
  • Operating temperature: -25 to 70 °C.
  • Storage temperature: -40 to 85 °C.
  • Standards: IEC/EN 60898-1 and IEC/EN 60947-2.

Acti9 C120N four-pole circuit breaker for high-current lines

The Schneider Electric A9N18376 combines a 125 A rated current, four protected poles, C curve and a 10 kA breaking capacity in a modular device designed for professional electrical panels. Its thermal-magnetic tripping unit protects against overloads and short circuits, while its suitability for isolation makes maintenance and disconnection tasks easier.

Compatibility with auxiliaries, remote monitoring and Vigi residual current blocks expands integration possibilities within the Acti9 ecosystem. To ensure proper protection, selection should be based on the circuit design current, conductor cross-section, prospective short-circuit current and actual installation conditions.

Specifications
Manufacturer
SCHNEIDER ELECTRIC
Reference
A9N18376
SKU
SCHEA01D33C
Object
Magnetic circuit breaker
Number of poles
Assembly
Adjustable in clip
Nominal current
125 A
Network type
CA
Protection rating
IP20
Frequency
50.00 - 60.00 Hz
Datasheets
Reviews
Returns within 30 days
Shop with peace of mind. If something goes wrong, we'll take care of it.
After-sales service
Any questions? Our support team will be happy to help you.
Pay how and when you want
Card, bank transfer, PayPal... Installment? We have them all.
GroupSumi is your online distributor for construction, electrical material and climate control.
All rights reserved © 2026 GroupSumi