The Schneider Electric Acti9 iC40N A9P54710 miniature circuit breaker is a 3P+N, 10 A, C-curve automatic circuit breaker designed to protect electrical circuits against overloads and short circuits. It features 3 protected poles plus neutral, with the neutral on the left, thermal-magnetic tripping technology, and a rated operational voltage of 400 V AC, making it suitable for residential and commercial distribution boards.
Reference A9P54710 offers a rated breaking capacity Icn of 6 kA at 400 V AC according to IEC/EN 60898-1 and an ultimate breaking capacity Icu of 10 kA at 400 V AC according to IEC/EN 60947-2. It is also part of Schneider Electric's modular Acti9 iC40 platform and incorporates VisiTrip and VisiSafe technologies to simplify diagnosis, maintenance, and circuit status identification.
The Schneider Electric A9P54710 has a 3P+N configuration. The three phase poles are protected by the thermal-magnetic trip unit, while the neutral is located on the left side of the device.
Its rated current is 10 A and it is designed for AC networks of 400 V and 50/60 Hz. This configuration makes it possible to protect three-phase circuits with neutral using a single compact device.
Reference A9P54710 uses a C tripping curve, widely used in electrical circuits that may present moderate inrush currents.
According to IEC/EN 60898-1, the magnetic trip is set between 5 and 10 times the rated current. In accordance with IEC/EN 60947-2, Schneider Electric specifies for this reference a magnetic threshold of 8 x In with a tolerance of ±20%.
The C curve makes this miniature circuit breaker suitable for many distribution circuits, provided that the rating, conductor cross-section, available short-circuit current, and load characteristics have been correctly calculated.
The Acti9 iC40N A9P54710 combines two protection principles in the same device:
This combination helps protect wiring and circuits against two of the main causes of overcurrent in low-voltage electrical installations.
The breaking capacity of reference A9P54710 must be stated together with the standard under which it is declared. Schneider Electric specifies at 400 V AC:
For this reason, the commercial 10 kA designation refers to the breaking capacity according to IEC/EN 60947-2, while the value declared under IEC/EN 60898-1 is 6,000 A.
VisiTrip technology makes it easy to identify a breaker that has operated due to an electrical fault. The front indication allows you to quickly distinguish the tripped device within a panel with multiple protections.
This function helps simplify diagnosis and maintenance tasks, reducing the time needed to locate the affected circuit.
The VisiSafe system provides a visible indication of the breaker contact status. This function is designed to improve safety and make it easier to identify the circuit status during maintenance work.
The A9P54710 is also suitable for isolation according to IEC/EN 60947-2, allowing it to be used to isolate the circuit within the conditions established by the manufacturer and applicable regulations.
The Acti9 iC40 range is designed as a modular platform. The A9P54710 miniature circuit breaker can be complemented with compatible electrical auxiliaries and remote monitoring devices to expand control and signalling functions in the panel.
It can also be associated with compatible Vigi residual current devices when differential protection needs to be added to the circuit. The A9P54710 miniature circuit breaker does not include residual current protection by itself.
The Schneider Electric Acti9 iC40N A9P54710 has a rated insulation voltage Ui of 440 V AC and a rated impulse withstand voltage Uimp of 4 kV.
The A9P54710 is designed for clip-on mounting on DIN rail, making it easy to integrate into modular electrical panels. Its compact format allows a 3P+N circuit to be protected while occupying a total width of only 54 mm.
The device occupies 6 modules of 9 mm, equivalent to 3 standard 18 mm modules.
The breaker terminals allow conductors of different cross-sections to be connected to adapt the wiring to the characteristics of the protected circuit.
Conductor sizing must always be carried out according to the design current, installation method, temperature, line length, voltage drop, and other conditions required by the applicable electrical regulations.
The Acti9 iC40N is designed to maintain its performance over a high number of operations. For reference A9P54710, Schneider Electric declares:
These features make it suitable for electrical panels where, in addition to protection, periodic switching operations may occur.
The miniature circuit breaker has an IP20 protection rating as a device and can reach IP40 when installed inside a suitable enclosure, according to Schneider Electric's conditions.
The Schneider Electric A9P54710 is developed in accordance with IEC/EN 60898-1 and IEC/EN 60947-2. These standards define, among other parameters, the tripping characteristics, breaking capacity, insulation, and behavior of the circuit breaker.
Therefore, when comparing the breaking capacity of this product, it is important to always identify the reference standard: 6 kA according to IEC/EN 60898-1 and 10 kA according to IEC/EN 60947-2 at 400 V AC.
The Schneider Electric Acti9 iC40N A9P54710 3P+N, 10 A, C-curve miniature circuit breaker offers a compact solution for protecting three-phase circuits with neutral against overloads and short circuits. Its breaking capacity of 6 kA according to IEC/EN 60898-1 and 10 kA according to IEC/EN 60947-2, together with VisiTrip and VisiSafe technologies, compatibility with Acti9 auxiliaries, and its 54 mm width format, make it easy to integrate into distribution electrical panels.