IC40N Circuit Breaker 3PN 40A Curve C 10kA with reference A9P54740 from the brand SCHNEIDER ELECTRIC
IC40N Circuit Breaker 3PN 40A Curve C 10kA with reference A9P54740 from the brand SCHNEIDER ELECTRIC
SCHNEIDER ELECTRIC

IC40N Circuit Breaker 3PN 40A Curve C 10kA

REF
A9P54740
(0)
94.80 €
€94.80
€441.81
Up to -6% for professionals. Discover it.
Schneider Electric Acti9 iC40N 3P+N 40 A circuit breaker, C curve and 6 kA breaking capacity. Protects circuits against overloads and short circuits with VisiTrip and VisiSafe.
Buy now and receive it between 20 and November 23
Express delivery
Get +95 +190 Sumis for the purchase
Receive 2x Sumis for a limited time
More about the product

Information about IC40N Circuit Breaker 3PN 40A Curve C 10kA

The Schneider Electric Acti9 iC40N A9P54740 circuit breaker is a modular miniature circuit breaker designed to protect electrical circuits against overloads and short circuits. It features a 3P+N configuration with 3 protected poles, a rated current of 40 A and a C tripping curve, providing protection for three-phase circuits with neutral in a compact 54 mm-wide format.

This circuit breaker provides a breaking capacity of 6000 A at 400 V AC according to IEC/EN 60898-1 and an Icu breaking capacity of 10 kA at 400 V AC according to IEC/EN 60947-2. It also incorporates Schneider Electric’s VisiTrip and VisiSafe technologies, which make it easy to identify tripping events and visually check the circuit open status.

40 A 3P+N circuit breaker

Reference A9P54740 has a 3P+N configuration. The three phase conductors are thermally and magnetically protected, while the neutral is disconnected simultaneously with the phases.

This configuration makes it possible to protect and disconnect three-phase circuits with neutral using a device of only 3 modules of 18 mm, helping optimize the available space inside the electrical panel.

  • Configuration: 3P+N.
  • Protected poles: 3.
  • Neutral position: left.
  • Rated current: 40 A.
  • Network type: AC.
  • Rated operational voltage: 400 V AC.
  • Frequency: 50/60 Hz.

C curve for distribution circuits

The Acti9 iC40N A9P54740 uses a C tripping curve, suitable for many distribution circuits and loads that may present moderate inrush currents.

According to IEC/EN 60898-1, magnetic tripping occurs within the range of 5 to 10 times the rated current. Schneider Electric also specifies a magnetic threshold of 8 x In ±20% according to IEC/EN 60947-2.

Thermal and magnetic protection

The circuit breaker incorporates a thermal-magnetic trip unit that combines two essential protection functions:

  • Thermal protection: acts when an overload keeps the current above the rated value for a certain period of time.
  • Magnetic protection: provides rapid disconnection when a high short-circuit current occurs.

This combination helps protect downstream conductors and equipment against the main overcurrents that can occur in an electrical installation.

6 kA / 10 kA breaking capacity

The interrupting capacity of the A9P54740 depends on the standard used to classify the device:

  • Icn: 6000 A at 400 V AC according to IEC/EN 60898-1.
  • Icu: 10 kA at 400 V AC according to IEC/EN 60947-2.
  • Ics according to IEC/EN 60898-1: 6 kA, equivalent to 100% of Icn.
  • Ics according to IEC/EN 60947-2: 5 kA, equivalent to 50% of Icu.

For this reason, the commercial 10 kA rating is correct when referring to breaking capacity according to IEC/EN 60947-2, while according to IEC/EN 60898-1 the nominal value is 6 kA.

VisiTrip for quickly locating the tripped circuit

The VisiTrip system provides a visual indication when the circuit breaker has operated due to an anomaly. This function helps quickly identify the affected circuit in panels with multiple protections, reducing diagnosis and maintenance times.

VisiSafe for greater safety

The VisiSafe technology makes it possible to visually check the contact status and provides a clear open indication. The A9P54740 is also suitable for isolation according to IEC/EN 60947-2, allowing it to be used as a circuit isolating device within the conditions indicated by Schneider Electric.

Limitation class 3

The circuit breaker has a limitation class 3 according to IEC/EN 60898-1. This feature limits the energy passing through the circuit during a short circuit, reducing thermal and electrodynamic stresses on downstream conductors and equipment.

Compact design to save space

One of the standout features of the Acti9 iC40 range is its slim-profile design. The 3P+N configuration occupies only 54 mm in width, equivalent to 3 standard 18 mm modules.

  • Height: 85 mm.
  • Width: 54 mm.
  • Depth: 74 mm.
  • 9 mm pitches: 6.
  • Net weight: approximately 345 g.
  • Color: white.

This format frees up space inside electrical panels and makes it easier to add other protection, control, or measurement devices.

DIN rail mounting

The A9P54740 is designed for clip-on DIN rail mounting. Its modular installation makes it easy to integrate alongside other Acti9 components.

Power supply can be connected from the top or bottom through its tunnel terminals, providing flexibility during panel wiring.

Conductor connection

The upper and lower terminals accept the following conductor sizes:

  • Rigid conductor: 1 to 16 mm².
  • Flexible conductor: 1 to 10 mm².
  • Strip length: 14 mm.
  • Tightening torque: 2 Nm.

Compatible with auxiliaries and Vigi residual current blocks

The Schneider Electric Acti9 iC40N can be complemented with electrical auxiliaries, signaling accessories, remote monitoring devices, and compatible Vigi residual current blocks.

This modularity makes it possible to expand protection functions when the installation requires status signaling, remote operation, or additional residual current protection.

Durability and environmental conditions

The A9P54740 is designed for professional installations and offers high mechanical and electrical service life:

  • Mechanical durability: 20,000 cycles.
  • Electrical durability: 10,000 cycles.
  • Operating temperature: -25 to 70 °C.
  • Storage temperature: -40 to 85 °C.
  • Relative humidity: up to 95% at 55 °C.
  • Maximum operating altitude: 2000 m.

Technical characteristics of the Schneider Electric A9P54740

  • Brand: Schneider Electric.
  • Reference: A9P54740.
  • Range: Acti9.
  • Product: Acti9 iC40N.
  • Type: modular thermal-magnetic circuit breaker.
  • Application: electrical distribution.
  • Configuration: 3P+N.
  • Protected poles: 3.
  • Neutral position: left.
  • Rated current: 40 A.
  • Curve: C.
  • Tripping technology: thermal-magnetic.
  • Network type: AC.
  • Rated operational voltage: 400 V AC.
  • Frequency: 50/60 Hz.
  • Breaking capacity Icn: 6 kA at 400 V according to IEC/EN 60898-1.
  • Breaking capacity Icu: 10 kA at 400 V according to IEC/EN 60947-2.
  • Limitation class: 3.
  • Rated insulation voltage Ui: 440 V AC.
  • Impulse withstand voltage Uimp: 4 kV.
  • Suitable for isolation: yes.
  • Trip indicator: VisiTrip.
  • Position indication: VisiSafe.
  • Mounting: clip-on DIN rail.
  • Width: 54 mm.
  • Height: 85 mm.
  • Depth: 74 mm.
  • Weight: approximately 345 g.
  • Rigid conductor: 1-16 mm².
  • Flexible conductor: 1-10 mm².
  • Tightening torque: 2 Nm.
  • Degree of protection: IP20.
  • Protection in modular enclosure: up to IP40.
  • Mechanical durability: 20,000 cycles.
  • Electrical durability: 10,000 cycles.
  • Operating temperature: -25 to 70 °C.
  • Standards: IEC/EN 60898-1 and IEC/EN 60947-2.
  • EAN: 3606481326188.

Compact three-phase protection for electrical panels

The Schneider Electric A9P54740 is a particularly interesting solution for protecting three-phase circuits with neutral when the available space in the panel is limited. Its 3P+N configuration occupies only three modules and combines overload and short-circuit protection with VisiTrip diagnostic and VisiSafe safety functions.

With 40 A, C curve, 6 kA according to IEC/EN 60898-1 and 10 kA according to IEC/EN 60947-2, the Acti9 iC40N offers a compact and expandable solution with auxiliaries and Vigi blocks for residential, commercial, and tertiary electrical distribution installations.

Specifications
Manufacturer
SCHNEIDER ELECTRIC
Reference
A9P54740
SKU
SCH5A16AB37
Object
Automatic switch
Number of poles
3P+N, 3P + N
Assembly
DIN rail. Clip adjustable.
Nominal current
40 A
Network type
AC
Protection rating
IP20
Color
White
Datasheets
Reviews
Returns within 30 days
Shop with peace of mind. If something goes wrong, we'll take care of it.
After-sales service
Any questions? Our support team will be happy to help you.
Pay how and when you want
Card, bank transfer, PayPal... Installment? We have them all.
GroupSumi is your online distributor for construction, electrical material and climate control.
All rights reserved © 2026 GroupSumi