IC60H 4P 16A Curve C Circuit Breaker with reference A9F89416 from the brand SCHNEIDER ELECTRIC
IC60H 4P 16A Curve C Circuit Breaker with reference A9F89416 from the brand SCHNEIDER ELECTRIC
SCHNEIDER ELECTRIC

IC60H 4P 16A Curve C Circuit Breaker

REF
A9F89416
(0)
Free shipping
166.50 €
€166.50
€425.85
Up to -11% for professionals. Discover it.
Schneider Electric Acti9 iC60H 4P 16 A C-curve miniature circuit breaker, 10 kA at 400 V and 15 kA Icu at 380-415 V, with VisiTrip and VisiSafe to protect against overloads and short circuits.
Buy now and receive it between 20 and November 23
Express free delivery
Get +167 +333 Sumis for the purchase
Receive 2x Sumis for a limited time
More about the product

Information about IC60H 4P 16A Curve C Circuit Breaker

The Schneider Electric Acti9 iC60H A9F89416 miniature circuit breaker is a modular automatic circuit breaker with 4 protected poles, 16 A and C curve, designed to protect electrical installations against overloads and short circuits. It stands out for its high breaking capacity, with 10 kA Icn at 400 V AC according to IEC/EN 60898-1 and 15 kA Icu at 380-415 V AC according to IEC/EN 60947-2. It incorporates VisiTrip and VisiSafe technologies, thermal-magnetic protection, energy limiting class 3 and suitability for isolation.

The A9F89416 reference belongs to Schneider Electric's Acti9 iC60H range, developed for circuits that require a higher breaking capacity than conventional modular miniature circuit breakers. Its four-pole configuration, DIN rail mounting and compatibility with auxiliaries, monitoring systems and Vigi residual current blocks make it easy to integrate into residential, commercial, tertiary and industrial electrical panels.

Four-pole 16 A miniature circuit breaker

The Schneider Electric A9F89416 has 4 poles and 4 protected poles, so the thermal-magnetic protection acts on the four conductors connected to the device.

  • Number of poles: 4P.
  • Protected poles: 4.
  • Rated current In: 16 A.
  • Curve: C.
  • Tripping technology: thermal-magnetic.
  • Application: electrical distribution.

Protection against overloads and short circuits

The Acti9 iC60H combines two operating principles:

  • Thermal protection: acts against sustained overloads that could cause excessive heating of the wiring.
  • Magnetic protection: provides rapid disconnection in the event of high currents caused by a short circuit.

In this way, the device protects conductors and the circuit against the main risks associated with overcurrents.

C curve

The A9F89416 reference uses a C tripping curve. Schneider Electric specifies a magnetic threshold of 8 × In ±20%.

The C curve offers a balance between fast short-circuit protection and tolerance to transient inrush currents, which is why it is commonly used in distribution circuits and loads with moderate starting peaks.

It can be used, provided the installation calculations allow it, in circuits such as:

  • General electrical distribution.
  • Lighting.
  • Sub-distribution boards.
  • General-purpose electrical equipment.
  • Small inductive loads.
  • Pumps and equipment with moderate inrush current.
  • Commercial and tertiary installations.
  • Automation panels.

10 kA according to IEC/EN 60898-1

According to IEC/EN 60898-1, the A9F89416 offers a rated breaking capacity Icn of 10,000 A at 400 V AC and 50/60 Hz.

Its service breaking capacity according to the same standard is:

  • Icn at 400 V AC: 10 kA.
  • Ics at 400 V AC: 7.5 kA, equivalent to 75% of Icn.

This high breaking capacity makes the iC60H suitable for installations where the prospective short-circuit current exceeds the performance of lower-capacity modular ranges.

15 kA Icu at 380-415 V according to IEC/EN 60947-2

When evaluated according to IEC/EN 60947-2, Schneider Electric specifies different ultimate breaking capacity Icu values depending on voltage:

  • 12-133 V AC: 42 kA.
  • 220-240 V AC: 30 kA.
  • 380-415 V AC: 15 kA.
  • 440 V AC: 10 kA.
  • Up to 250 V DC: 15 kA.

Therefore, the 10 kA and 15 kA values commercially associated with this product are both correct, but they correspond to different standards and test conditions.

Service breaking capacity Ics

According to IEC/EN 60947-2, the main Ics values are:

  • 220-240 V AC: 15 kA.
  • 380-415 V AC: 7.5 kA.
  • 440 V AC: 5 kA.
  • Up to 250 V DC: 15 kA.

Before selecting the circuit breaker, it must be checked that its breaking capacity is suitable for the maximum prospective short-circuit current at the installation point.

Energy limiting class 3

The A9F89416 has energy limiting class 3 according to IEC/EN 60898-1.

This capability helps reduce the energy and peak current flowing through the circuit during a short circuit, lowering the thermal and electrodynamic stresses on conductors and downstream devices.

VisiTrip for quick trip identification

The VisiTrip system provides local indication that makes it easy to identify the breaker that has tripped due to a fault.

In panels with many circuits, this function helps quickly locate the affected outgoing circuit and can reduce the time needed to diagnose the issue.

VisiSafe for safe open-contact verification

The VisiSafe technology allows visual confirmation that the contacts are physically open through the corresponding device indication.

The circuit breaker is also suitable for isolation according to IEC/EN 60898-1 and IEC/EN 60947-2 and is suitable for industrial isolation according to IEC/EN 60947-2.

Protection for professional installations

The iC60H range offers a higher breaking capacity than the equivalent iC60N range, making it especially interesting in panels where high short-circuit currents are expected.

This feature makes it suitable for professional and industrial distribution applications, provided the rest of the electrical parameters are appropriate for the circuit.

Insulation characteristics

  • Rated insulation voltage Ui: 500 V AC.
  • Rated impulse withstand voltage Uimp: 6 kV.
  • Utilization category: A according to IEC/EN 60947-2.
  • Overvoltage category: IV.
  • Pollution degree: 3.
  • Frequency: 50/60 Hz.

Use in AC and DC

Schneider Electric specifies the iC60H A9F89416 for AC and DC applications within its rated conditions.

In DC, it has an Icu of 15 kA up to 250 V DC. In this type of installation, the connection diagrams, maximum voltage and pole configuration established by Schneider Electric must be strictly observed.

DIN rail mounting

The A9F89416 is designed for fixed clip-on mounting on DIN rail, making it easy to integrate with other Acti9 modular devices.

  • Mounting: fixed on DIN rail.
  • 9 mm steps: 8.
  • Modular width: 4 modules of 18 mm.

Dimensions of the Schneider Electric A9F89416

  • Width: 72 mm.
  • Height: 85 mm.
  • Depth: 78.5 mm.
  • Net weight: approximately 0.5 kg.
  • Color: white RAL 9003.

Its four-module format allows high-breaking-capacity four-pole thermal-magnetic protection to be incorporated into standard modular electrical panels.

Top or bottom connection

The terminals allow connection from the top or bottom of the device and accept compatible distribution combs.

  • Rigid conductor: 1 to 25 mm².
  • Flexible conductor: 1 to 16 mm².
  • Strip length: 14 mm.
  • Tightening torque: 2 Nm.

Proper conductor preparation and tightening are essential to ensure a reliable connection and avoid abnormal heating at the terminals.

Compatible with Acti9 auxiliaries and monitoring

The iC60H can be complemented with different accessories from the Acti9 platform to expand the panel's protection and monitoring functions.

Schneider Electric allows the addition of:

  • Auxiliary contacts.
  • Signalling contacts.
  • Auxiliary trip units.
  • Remote monitoring devices.
  • Locking accessories.
  • Compatible distribution combs.
  • Compatible Vigi residual current blocks.

Compatibility must always be checked with the specific accessory reference.

Possibility of adding Vigi residual current protection

The A9F89416 is an MCB circuit breaker and provides protection against overloads and short circuits.

It does not include integrated residual current protection against earth leakage. When this function is required, it can be used together with suitable residual current protection or associated with a compatible Vigi block in accordance with Schneider Electric instructions.

Durability of the Acti9 iC60H

  • Mechanical durability: up to 20,000 cycles.
  • Electrical durability: up to 10,000 cycles.

This robustness makes it suitable for professional installations subject to regular switching, testing and maintenance operations.

IP20 protection rating

The circuit breaker has an IP20 protection rating according to IEC 60529.

It must be installed inside a suitable enclosure or electrical panel that provides the environmental protection level required by the application.

Environmental conditions

  • Operating ambient temperature: -35 to 70 °C.
  • Storage temperature: -40 to 85 °C.
  • Operating altitude: up to 2,000 m.

Applications of the A9F89416 circuit breaker

Thanks to its 16 A rated current, C curve and high breaking capacity, this circuit breaker can be used in different distribution circuits provided electrical calculations confirm its suitability.

  • Main and sub-distribution boards.
  • Commercial installations.
  • Office buildings.
  • Tertiary installations.
  • Industrial panels.
  • Lighting circuits.
  • Auxiliary circuits.
  • Small inductive loads.
  • Three-phase lines requiring four protected poles.

Technical characteristics of the Schneider Electric A9F89416

  • Brand: Schneider Electric.
  • Reference: A9F89416.
  • Range: Acti9.
  • Family: Acti9 iC60.
  • Model: iC60H.
  • Type: modular thermal-magnetic circuit breaker MCB.
  • Application: electrical distribution.
  • Number of poles: 4P.
  • Protected poles: 4.
  • Rated current: 16 A.
  • Curve: C.
  • Tripping technology: thermal-magnetic.
  • Magnetic threshold: 8 × In ±20%.
  • Icn at 400 V AC according to IEC/EN 60898-1: 10 kA.
  • Ics at 400 V AC according to IEC/EN 60898-1: 7.5 kA.
  • Icu at 220-240 V AC: 30 kA.
  • Icu at 380-415 V AC: 15 kA.
  • Icu at 440 V AC: 10 kA.
  • Icu up to 250 V DC: 15 kA.
  • Ics at 220-240 V AC according to IEC/EN 60947-2: 15 kA.
  • Ics at 380-415 V AC according to IEC/EN 60947-2: 7.5 kA.
  • Ics at 440 V AC according to IEC/EN 60947-2: 5 kA.
  • Energy limiting class: 3.
  • Network type: AC/DC.
  • Frequency: 50/60 Hz.
  • Utilization category: A.
  • Rated insulation voltage Ui: 500 V AC.
  • Rated impulse withstand voltage Uimp: 6 kV.
  • Overvoltage category: IV.
  • Pollution degree: 3.
  • Suitable for isolation: yes.
  • Suitable for industrial isolation: yes.
  • VisiTrip: yes.
  • VisiSafe: yes.
  • Local trip indication: yes.
  • Contact position indicator: yes.
  • Actuator: toggle lever.
  • Mounting: DIN rail.
  • Width: 72 mm.
  • Height: 85 mm.
  • Depth: 78.5 mm.
  • Weight: approximately 0.5 kg.
  • Rigid conductor: 1-25 mm².
  • Flexible conductor: 1-16 mm².
  • Strip length: 14 mm.
  • Tightening torque: 2 Nm.
  • Protection rating: IP20.
  • Mechanical durability: 20,000 cycles.
  • Electrical durability: 10,000 cycles.
  • Operating temperature: -35 to 70 °C.
  • Storage temperature: -40 to 85 °C.
  • Maximum operating altitude: 2,000 m.
  • Integrated residual current protection: no.
  • Standards: IEC/EN 60898-1 and IEC/EN 60947-2.
  • EAN: 3606480095214.

High breaking capacity in modular format

The Schneider Electric Acti9 iC60H A9F89416 combines four protected poles, 16 A and C curve with a high breaking capacity: 10 kA Icn at 400 V according to IEC/EN 60898-1 and 15 kA Icu at 380-415 V according to IEC/EN 60947-2.

Its VisiTrip and VisiSafe systems make fault location and maintenance operations easier, while compatibility with auxiliaries and Vigi blocks allows the device's functions to be expanded within the Acti9 platform.

Important: before installing the A9F89416, the design current, conductor cross-section, tripping curve, minimum and maximum short-circuit current and required breaking capacity must be checked. This device does not include residual current protection; when protection against earth leakage is required, it must be complemented with a suitable residual current device.

Specifications
Manufacturer
SCHNEIDER ELECTRIC
Reference
A9F89416
SKU
SCH92FAC9AB
Object
Magnetic circuit breaker
Number of poles
Assembly
Fixed
Nominal current
16 A
Network type
CA, CC
Protection rating
IP20
Frequency
50.00 - 60.00 Hz
Datasheets
Reviews
Returns within 30 days
Shop with peace of mind. If something goes wrong, we'll take care of it.
After-sales service
Any questions? Our support team will be happy to help you.
Pay how and when you want
Card, bank transfer, PayPal... Installment? We have them all.
GroupSumi is your online distributor for construction, electrical material and climate control.
All rights reserved © 2026 GroupSumi