The Schneider Electric Acti9 iC60H A9F89450 thermal-magnetic circuit breaker is a four-pole automatic breaker rated at 50 A with C curve, designed to protect electrical circuits against overloads and short circuits. It features 4 poles with all 4 poles protected, thermal-magnetic tripping technology and a high breaking capacity, making it especially suitable for residential, commercial and industrial electrical panels with higher protection requirements.
Reference A9F89450 offers a rated breaking capacity Icn of 10 kA at 400 V AC according to IEC/EN 60898-1 and an ultimate breaking capacity Icu of 15 kA at 380-415 V AC according to IEC/EN 60947-2. It also integrates Schneider Electric’s VisiTrip and VisiSafe technologies, which make it easier to identify tripping events and verify the open status of the circuit.
The Schneider Electric A9F89450 features a 4P configuration with protection on all four poles. Its rated current is 50 A and it can operate in both AC networks and certain DC applications within the limits established by the manufacturer.
The Acti9 iC60H A9F89450 uses a C tripping curve. Schneider Electric specifies for this reference a magnetic tripping threshold of 8 times the rated current with a ±20% tolerance in accordance with IEC/EN 60947-2.
This feature makes the circuit breaker suitable for many distribution circuits with loads that may present moderate inrush currents. The correct choice of rating and curve should be made taking into account the installation characteristics, conductor cross-section and available short-circuit current.
The A9F89450 combines two operating systems. The thermal mechanism protects against sustained overloads that could cause excessive heating of the conductors, while the magnetic mechanism provides rapid disconnection in the event of high short-circuit currents.
This combination allows the device to be used as main protection for lines and distribution circuits within low-voltage electrical panels.
According to IEC/EN 60898-1, Schneider Electric declares for this circuit breaker a rated breaking capacity Icn of 10,000 A at 400 V AC. Its energy limiting class is 3.
According to IEC/EN 60947-2, the ultimate breaking capacity Icu varies depending on the operating voltage:
For this reason, the 15 kA figure commonly associated with the iC60H corresponds to its Icu capacity at 380-415 V according to IEC/EN 60947-2, while according to IEC/EN 60898-1 its rated breaking capacity is 10 kA at 400 V AC.
The service breaking capacity indicates the breaker’s ability to continue providing performance after interrupting a short-circuit current under the conditions established by the standard.
VisiTrip technology provides local indication that allows you to quickly identify that the circuit breaker has operated due to an electrical fault. This function makes diagnosis easier in panels with many circuits and helps reduce the time needed to locate the tripped protection device.
The VisiSafe system provides a visible indication related to contact opening, making it easier to check the breaker status during maintenance tasks.
The A9F89450 is also suitable for isolation in accordance with IEC/EN 60898-1 and IEC/EN 60947-2, providing an additional circuit isolation function within the conditions specified by the manufacturer.
The Acti9 iC60H is part of Schneider Electric’s modular system and can be complemented with electrical auxiliaries, signalling accessories and remote monitoring devices.
It also supports association with a compatible Vigi residual current block when the circuit requires residual current protection. Residual current protection is not integrated as standard in reference A9F89450.
The circuit breaker offers high insulation characteristics for professional installations:
The Schneider Electric A9F89450 is designed for fixed mounting on a DIN rail. Its four poles occupy 8 modules of 9 mm, equivalent to a total width of 72 mm or four standard 18 mm modules.
As a 50 A rating, its terminals accept copper conductors with cross-sections suitable for power circuits. The iC60H range documentation specifies for ratings between 32 and 63 A:
The final cable sizing must be carried out according to design current, installation method, line length, temperature, voltage drop and applicable regulations.
The Acti9 iC60H is designed to offer a long service life within distribution panels. Reference A9F89450 achieves a mechanical durability of up to 20,000 cycles and an electrical durability of up to 10,000 cycles under the conditions indicated by Schneider Electric.
The power loss indicated for this model is approximately 4 W.
The circuit breaker offers an IP20 protection rating as a modular device and is intended to be installed in a suitable panel or electrical enclosure.
The Schneider Electric Acti9 iC60H A9F89450 4-pole, 50 A, C-curve thermal-magnetic circuit breaker offers a high-capacity solution for protecting circuits against overloads and short circuits. Its 10 kA breaking capacity according to IEC/EN 60898-1 and 15 kA at 380-415 V according to IEC/EN 60947-2, together with VisiTrip and VisiSafe technologies, Acti9 auxiliary compatibility and the possibility of adding Vigi residual current protection, make it an especially suitable choice for professional electrical panels.