Schneider Electric Acti9 iC60H 4P 50A C-curve miniature circuit breaker, 10 kA IEC 60898-1 and 15 kA IEC 60947-2, with VisiTrip and VisiSafe for circuit protection.
Buy now and receive it between 20 and November 23
Express free delivery
Get +275 +550 Sumis for the purchase
Receive 2x Sumis for a limited time
More about the product

Information about IC60H 4P 50A Circuit Breaker Curve C

The Schneider Electric Acti9 iC60H A9F89450 thermal-magnetic circuit breaker is a four-pole automatic breaker rated at 50 A with C curve, designed to protect electrical circuits against overloads and short circuits. It features 4 poles with all 4 poles protected, thermal-magnetic tripping technology and a high breaking capacity, making it especially suitable for residential, commercial and industrial electrical panels with higher protection requirements.

Reference A9F89450 offers a rated breaking capacity Icn of 10 kA at 400 V AC according to IEC/EN 60898-1 and an ultimate breaking capacity Icu of 15 kA at 380-415 V AC according to IEC/EN 60947-2. It also integrates Schneider Electric’s VisiTrip and VisiSafe technologies, which make it easier to identify tripping events and verify the open status of the circuit.

Four-pole 50 A circuit breaker

The Schneider Electric A9F89450 features a 4P configuration with protection on all four poles. Its rated current is 50 A and it can operate in both AC networks and certain DC applications within the limits established by the manufacturer.

  • Number of poles: 4P.
  • Protected poles: 4.
  • Rated current: 50 A.
  • Tripping curve: C.
  • Tripping technology: thermal-magnetic.
  • Network type: AC and DC.
  • Frequency: 50/60 Hz.

C curve for distribution circuits

The Acti9 iC60H A9F89450 uses a C tripping curve. Schneider Electric specifies for this reference a magnetic tripping threshold of 8 times the rated current with a ±20% tolerance in accordance with IEC/EN 60947-2.

This feature makes the circuit breaker suitable for many distribution circuits with loads that may present moderate inrush currents. The correct choice of rating and curve should be made taking into account the installation characteristics, conductor cross-section and available short-circuit current.

Thermal-magnetic protection against overloads and short circuits

The A9F89450 combines two operating systems. The thermal mechanism protects against sustained overloads that could cause excessive heating of the conductors, while the magnetic mechanism provides rapid disconnection in the event of high short-circuit currents.

This combination allows the device to be used as main protection for lines and distribution circuits within low-voltage electrical panels.

10 kA breaking capacity according to IEC/EN 60898-1

According to IEC/EN 60898-1, Schneider Electric declares for this circuit breaker a rated breaking capacity Icn of 10,000 A at 400 V AC. Its energy limiting class is 3.

According to IEC/EN 60947-2, the ultimate breaking capacity Icu varies depending on the operating voltage:

  • 12-133 V AC: 42 kA.
  • 220-240 V AC: 30 kA.
  • 380-415 V AC: 15 kA.
  • 440 V AC: 10 kA.
  • Up to 250 V DC: 15 kA.

For this reason, the 15 kA figure commonly associated with the iC60H corresponds to its Icu capacity at 380-415 V according to IEC/EN 60947-2, while according to IEC/EN 60898-1 its rated breaking capacity is 10 kA at 400 V AC.

Service breaking capacity Ics

The service breaking capacity indicates the breaker’s ability to continue providing performance after interrupting a short-circuit current under the conditions established by the standard.

  • Ics at 12-133 V AC: 21 kA.
  • Ics at 220-240 V AC: 15 kA.
  • Ics at 380-415 V AC: 7.5 kA.
  • Ics at 440 V AC: 5 kA.
  • Ics up to 250 V DC: 15 kA.

VisiTrip for quick fault identification

VisiTrip technology provides local indication that allows you to quickly identify that the circuit breaker has operated due to an electrical fault. This function makes diagnosis easier in panels with many circuits and helps reduce the time needed to locate the tripped protection device.

VisiSafe for improved safety

The VisiSafe system provides a visible indication related to contact opening, making it easier to check the breaker status during maintenance tasks.

The A9F89450 is also suitable for isolation in accordance with IEC/EN 60898-1 and IEC/EN 60947-2, providing an additional circuit isolation function within the conditions specified by the manufacturer.

Compatible with auxiliaries and Vigi residual current protection

The Acti9 iC60H is part of Schneider Electric’s modular system and can be complemented with electrical auxiliaries, signalling accessories and remote monitoring devices.

It also supports association with a compatible Vigi residual current block when the circuit requires residual current protection. Residual current protection is not integrated as standard in reference A9F89450.

500 V insulation and 6 kV impulse withstand

The circuit breaker offers high insulation characteristics for professional installations:

  • Rated insulation voltage Ui: 500 V AC.
  • Rated impulse withstand voltage Uimp: 6 kV.
  • Overvoltage category: IV.
  • Pollution degree: 3.
  • Utilization category: category A according to IEC/EN 60947-2.

Modular DIN rail mounting

The Schneider Electric A9F89450 is designed for fixed mounting on a DIN rail. Its four poles occupy 8 modules of 9 mm, equivalent to a total width of 72 mm or four standard 18 mm modules.

  • Height: 85 mm.
  • Width: 72 mm.
  • Depth: 78.5 mm.
  • Installation depth: 44.5 mm.
  • Approximate weight: 0.5 kg.
  • Mounting: fixed on DIN rail.
  • Modular width: 8 modules of 9 mm.

Connection for large cross-section conductors

As a 50 A rating, its terminals accept copper conductors with cross-sections suitable for power circuits. The iC60H range documentation specifies for ratings between 32 and 63 A:

  • Rigid conductor: up to 35 mm².
  • Flexible conductor: up to 25 mm².
  • Strip length: 14 mm.
  • Tightening torque: up to 3.5 Nm.

The final cable sizing must be carried out according to design current, installation method, line length, temperature, voltage drop and applicable regulations.

High mechanical and electrical durability

The Acti9 iC60H is designed to offer a long service life within distribution panels. Reference A9F89450 achieves a mechanical durability of up to 20,000 cycles and an electrical durability of up to 10,000 cycles under the conditions indicated by Schneider Electric.

The power loss indicated for this model is approximately 4 W.

IP20 protection and operation up to 70 °C

The circuit breaker offers an IP20 protection rating as a modular device and is intended to be installed in a suitable panel or electrical enclosure.

  • Protection rating: IP20.
  • Operating ambient temperature: -35 to 70 °C.
  • Storage temperature: -40 to 85 °C.
  • Relative humidity: up to 95% at 55 °C.
  • Maximum operating altitude: 2,000 m.

Schneider Electric A9F89450 technical characteristics

  • Brand: Schneider Electric.
  • Range: Acti9.
  • Series: Acti9 iC60.
  • Model: iC60H.
  • Reference: A9F89450.
  • Type: thermal-magnetic circuit breaker.
  • Application: electrical distribution.
  • Number of poles: 4P.
  • Protected poles: 4.
  • Rated current: 50 A.
  • Curve: C.
  • Trip unit: thermal-magnetic.
  • Magnetic threshold: 8 x In ±20%.
  • Network type: AC/DC.
  • Frequency: 50/60 Hz.
  • Icn at 400 V AC according to IEC/EN 60898-1: 10 kA.
  • Icu at 380-415 V AC according to IEC/EN 60947-2: 15 kA.
  • Icu at 220-240 V AC: 30 kA.
  • Icu at 440 V AC: 10 kA.
  • Icu up to 250 V DC: 15 kA.
  • Limiting class: 3.
  • Insulation voltage Ui: 500 V AC.
  • Rated impulse withstand voltage Uimp: 6 kV.
  • Overvoltage category: IV.
  • VisiTrip: yes.
  • VisiSafe: yes.
  • Suitable for isolation: yes.
  • Compatible with Acti9 auxiliaries: yes.
  • Residual current protection: via compatible independent Vigi block.
  • Rigid conductor: up to 35 mm².
  • Flexible conductor: up to 25 mm².
  • Mounting: DIN rail.
  • Dimensions: 85 x 72 x 78.5 mm.
  • Approximate weight: 0.5 kg.
  • Mechanical durability: 20,000 cycles.
  • Electrical durability: 10,000 cycles.
  • Power loss: approximately 4 W.
  • Protection rating: IP20.
  • Operating temperature: -35 to 70 °C.
  • Standards: IEC/EN 60898-1 and IEC/EN 60947-2.

The Schneider Electric Acti9 iC60H A9F89450 4-pole, 50 A, C-curve thermal-magnetic circuit breaker offers a high-capacity solution for protecting circuits against overloads and short circuits. Its 10 kA breaking capacity according to IEC/EN 60898-1 and 15 kA at 380-415 V according to IEC/EN 60947-2, together with VisiTrip and VisiSafe technologies, Acti9 auxiliary compatibility and the possibility of adding Vigi residual current protection, make it an especially suitable choice for professional electrical panels.

Specifications
Manufacturer
SCHNEIDER ELECTRIC
Reference
A9F89450
SKU
SCH469CF6C0
Object
Magnetic circuit breaker
Number of poles
Assembly
Fixed
Nominal current
50 A
Network type
CA, CC
Protection rating
IP20
Frequency
50.00 - 60.00 Hz
Datasheets
Reviews
Returns within 30 days
Shop with peace of mind. If something goes wrong, we'll take care of it.
After-sales service
Any questions? Our support team will be happy to help you.
Pay how and when you want
Card, bank transfer, PayPal... Installment? We have them all.
GroupSumi is your online distributor for construction, electrical material and climate control.
All rights reserved © 2026 GroupSumi