IC60H 4P 63A Circuit Breaker Curve D with reference A9F85463 from the brand SCHNEIDER ELECTRIC
IC60H 4P 63A Circuit Breaker Curve D with reference A9F85463 from the brand SCHNEIDER ELECTRIC
SCHNEIDER ELECTRIC

IC60H 4P 63A Circuit Breaker Curve D

REF
A9F85463
(0)
Free shipping
436.00 €
€436.00
€1,217.98
Up to -6% for professionals. Discover it.
Schneider Electric Acti9 iC60H 4P 63 A circuit breaker, D curve and 10 kA breaking capacity. Protects circuits with high inrush currents against overloads and short circuits.
Buy now and receive it between 20 and November 23
Express free delivery
Get +436 +872 Sumis for the purchase
Receive 2x Sumis for a limited time
More about the product

Information about IC60H 4P 63A Circuit Breaker Curve D

The Schneider Electric Acti9 iC60H A9F85463 miniature circuit breaker is a modular automatic circuit breaker with 4 protected poles, 63 A and D tripping curve, designed to protect electrical circuits against overloads and short circuits. Its high breaking capacity and D curve make it an especially suitable solution for professional and industrial installations with loads that can generate high inrush currents.

The A9F85463 offers an Icn breaking capacity of 10 kA at 400 V AC according to IEC/EN 60898-1 and an Icu breaking capacity of 15 kA at 380-415 V AC according to IEC/EN 60947-2. It incorporates thermal-magnetic tripping technology and the VisiTrip and VisiSafe functions characteristic of the Acti9 range, making it easier to identify trips and increasing safety during maintenance operations.

Four-pole 63 A miniature circuit breaker

The A9F85463 reference has a 4P configuration, with thermal and magnetic protection on all four poles. This allows all conductors in the circuit to be disconnected simultaneously when an overload or short circuit occurs.

  • Number of poles: 4P.
  • Protected poles: 4.
  • Rated current: 63 A.
  • Curve: D.
  • Tripping technology: thermal-magnetic.
  • Network type: AC and DC.

D curve for loads with high inrush currents

The D curve is especially suitable for circuits where loads can generate high inrush currents. Schneider Electric specifies for this model a magnetic tripping threshold of 12 x In ±20 %.

This feature allows it to withstand current peaks higher than those usually accepted by B or C curve miniature circuit breakers before instantaneous tripping occurs. For this reason, it may be suitable for certain motors, transformers, machinery and other inductive loads, provided the circuit sizing is compatible.

Protection against overloads and short circuits

The Acti9 iC60H combines two complementary protection systems:

  • Thermal protection: acts against sustained overloads that can cause overheating of the conductors.
  • Magnetic protection: provides rapid disconnection when a high short-circuit current occurs.

This technology protects both the wiring and the equipment downstream from the main overcurrent situations.

Breaking capacity up to 42 kA depending on voltage

The breaking capacity of the Schneider Electric A9F85463 depends on the voltage and the standard applied. According to IEC/EN 60947-2, the manufacturer specifies:

  • 42 kA Icu between 12 and 60 V AC.
  • 42 kA Icu between 100 and 133 V AC.
  • 30 kA Icu between 220 and 240 V AC.
  • 15 kA Icu between 380 and 415 V AC.
  • 10 kA Icu at 440 V AC.
  • 15 kA Icu up to 250 V DC.

According to IEC/EN 60898-1, its rated breaking capacity Icn is 10,000 A at 400 V AC.

VisiTrip for quick trip identification

The VisiTrip technology incorporates a front mechanical indicator that makes it possible to quickly locate a miniature circuit breaker that has tripped due to an electrical fault.

This function is especially practical in panels with numerous circuits, as it facilitates diagnosis and helps reduce intervention and maintenance times.

VisiSafe and suitability for isolation

The VisiSafe system allows the open state of the contacts to be visually checked through a green indication in the mechanism. The A9F85463 is also suitable for industrial isolation according to IEC/EN 60947-2.

These features provide an additional visual reference before carrying out maintenance work on the downstream circuit.

Class 3 current limiting

The iC60H has a current limiting class 3 according to IEC/EN 60898-1. This feature helps limit the energy passing through the circuit during a short circuit, reducing the thermal and electrodynamic stresses on the protected conductors and equipment.

Modular DIN rail mounting

The miniature circuit breaker is designed for fixed installation on DIN rail and occupies four standard 18 mm modules.

  • Height: 85 mm.
  • Width: 72 mm.
  • Depth: 78.5 mm.
  • 9 mm pitches: 8.
  • Weight: approximately 0.5 kg.
  • Color: white.

Power supply can be connected from the top or bottom, and the device is compatible with Acti9 comb busbar systems.

Connection of conductors up to 35 mm²

The A9F85463 is equipped with terminals for copper conductors and supports:

  • Rigid conductor: 1 to 35 mm².
  • Flexible conductor: 1 to 25 mm².
  • Strip length: 14 mm.
  • Tightening torque: 3.5 Nm.

These connection capabilities make it easy to use in high-current circuits within distribution switchboards.

Compatible with auxiliaries and Vigi residual current protection

The Acti9 iC60 range allows the miniature circuit breaker to be complemented with signaling and tripping auxiliaries, remote monitoring systems and compatible Vigi residual current blocks.

This makes it possible to expand the installation with signaling, remote operation or residual current protection functions without giving up the modular format of the Acti9 system.

Durability and environmental conditions

The Schneider Electric A9F85463 is designed for professional applications that require a long service life:

  • Mechanical durability: 20,000 cycles.
  • Electrical durability: 10,000 cycles.
  • Operating temperature: -35 to 70 °C.
  • Storage temperature: -40 to 85 °C.
  • Relative humidity: up to 95% at 55 °C.
  • Maximum operating altitude: 2,000 m.

Technical characteristics of the Schneider Electric A9F85463

  • Brand: Schneider Electric.
  • Reference: A9F85463.
  • Range: Acti9.
  • Product: Acti9 iC60H.
  • Type: modular thermal-magnetic circuit breaker.
  • Application: electrical distribution.
  • Number of poles: 4P.
  • Protected poles: 4.
  • Rated current: 63 A.
  • Tripping curve: D.
  • Magnetic threshold: 12 x In ±20 %.
  • Tripping technology: thermal-magnetic.
  • Network type: AC and DC.
  • Frequency: 50/60 Hz.
  • Icn according to IEC/EN 60898-1: 10 kA at 400 V AC.
  • Icu according to IEC/EN 60947-2: 30 kA at 220-240 V AC.
  • Icu according to IEC/EN 60947-2: 15 kA at 380-415 V AC.
  • Icu according to IEC/EN 60947-2: 10 kA at 440 V AC.
  • Icu in direct current: 15 kA up to 250 V DC.
  • Utilization category: A.
  • Limiting class: 3.
  • Rated insulation voltage Ui: 500 V AC.
  • Impulse withstand voltage Uimp: 6 kV.
  • Suitable for isolation: yes.
  • Trip indicator: VisiTrip.
  • Open indication: VisiSafe.
  • Mounting: fixed on DIN rail.
  • Width: 72 mm.
  • Height: 85 mm.
  • Depth: 78.5 mm.
  • Weight: approximately 0.5 kg.
  • Rigid conductor: 1-35 mm².
  • Flexible conductor: 1-25 mm².
  • Tightening torque: 3.5 Nm.
  • Protection rating: IP20.
  • Overvoltage category: IV.
  • Pollution degree: 3.
  • Mechanical durability: 20,000 cycles.
  • Electrical durability: 10,000 cycles.
  • Operating temperature: -35 to 70 °C.
  • Maximum altitude: 2,000 m.
  • Standards: IEC/EN 60898-1 and IEC/EN 60947-2.
  • EAN: 3606480083457.

Four-pole protection for loads with high inrush currents

The Schneider Electric A9F85463 is especially suitable for 63 A circuits supplying loads capable of generating strong current peaks during startup. Its D curve allows these transient currents to be tolerated within the specified limits before magnetic tripping occurs.

The combination of 4 protected poles, 63 A, D curve, 10 kA according to IEC/EN 60898-1, 15 kA at 380-415 V according to IEC/EN 60947-2 and VisiTrip and VisiSafe technologies provides a robust solution for distribution switchboards in commercial, tertiary and industrial installations.

Specifications
Manufacturer
SCHNEIDER ELECTRIC
Reference
A9F85463
SKU
SCHB9E98BBB
Object
Magnetic circuit breaker
Number of poles
Assembly
Fixed
Nominal current
63 A
Network type
CA, CC
Protection rating
IP20
Frequency
50.00 - 60.00 Hz
Datasheets
Reviews
Returns within 30 days
Shop with peace of mind. If something goes wrong, we'll take care of it.
After-sales service
Any questions? Our support team will be happy to help you.
Pay how and when you want
Card, bank transfer, PayPal... Installment? We have them all.
GroupSumi is your online distributor for construction, electrical material and climate control.
All rights reserved © 2026 GroupSumi