IC60H Circuit Breaker 2P 6A Curve C with reference A9F89206 from the brand SCHNEIDER ELECTRIC
IC60H Circuit Breaker 2P 6A Curve C with reference A9F89206 from the brand SCHNEIDER ELECTRIC
SCHNEIDER ELECTRIC

IC60H Circuit Breaker 2P 6A Curve C

REF
A9F89206
(0)
70.31 €
€70.31
€221.11
Up to -6% for professionals. Discover it.
Schneider Electric Acti9 iC60H 2P 6 A C-curve miniature circuit breaker, 10 kA at 400 V and 15 kA Icu at 380-415 V, with VisiTrip and VisiSafe for electrical overloads and short circuits.
Buy now and receive it between 20 and November 23
Express delivery
Get +71 +141 Sumis for the purchase
Receive 2x Sumis for a limited time
More about the product

Information about IC60H Circuit Breaker 2P 6A Curve C

The Schneider Electric Acti9 iC60H A9F89206 miniature circuit breaker is a modular automatic circuit breaker with 2 protected poles, 6 A and C curve, designed to protect electrical circuits against overloads and short circuits. It stands out for its high breaking capacity, with an Icn breaking capacity of 10 kA at 400 V AC according to IEC/EN 60898-1 and an Icu of 15 kA at 380-415 V AC according to IEC/EN 60947-2. It incorporates VisiTrip and VisiSafe technologies, thermal-magnetic protection and suitability for isolation, offering a solution especially suitable for professional distribution boards where a higher breaking capacity than a conventional 6 kA miniature circuit breaker is required.

Reference A9F89206 belongs to Schneider Electric's Acti9 iC60H range. Its bipolar configuration allows both conductors connected to the device to be protected simultaneously, while its two-module format, DIN rail mounting and compatibility with auxiliaries and Vigi residual current blocks make it easy to integrate into residential, commercial, tertiary and industrial panels.

6 A bipolar miniature circuit breaker

The Schneider Electric A9F89206 has 2 poles and 2 protected poles. Both conductors are protected by the thermal-magnetic tripping system and are disconnected simultaneously when the breaker trips.

  • Number of poles: 2P.
  • Protected poles: 2.
  • Rated current In: 6 A.
  • Tripping curve: C.
  • Technology: thermal-magnetic.
  • Application: electrical distribution.

Protection against overloads and short circuits

The Acti9 iC60H combines two protection mechanisms:

  • Thermal protection: acts when an overload persists long enough to cause excessive heating of the conductors.
  • Magnetic protection: provides rapid disconnection when a high short-circuit current occurs.

This combination helps protect wiring and loads against the main risks associated with overcurrent.

C curve for loads with moderate inrush currents

The A9F89206 incorporates a C curve. Schneider Electric specifies a magnetic tripping threshold of 8 × In ±20 %.

This feature allows certain transient current peaks to be tolerated without immediate magnetic tripping, provided the installation has been correctly designed.

Depending on the specific circuit characteristics, the C curve can be used in applications such as:

  • Distribution circuits.
  • Lighting.
  • General-purpose electrical equipment.
  • Small inductive loads.
  • Automation panels.
  • Auxiliary circuits.
  • Commercial and tertiary installations.

10 kA according to IEC/EN 60898-1

According to IEC/EN 60898-1, the Schneider Electric A9F89206 has a rated breaking capacity Icn of 10,000 A at 400 V AC.

This value is one of the main differences between the iC60H and the lower breaking capacity iC60N versions.

The service breaking capacity according to the same standard is:

  • Icn at 400 V AC: 10 kA.
  • Ics at 400 V AC: 7.5 kA, equivalent to 75% of Icn.

15 kA according to IEC/EN 60947-2 at 380-415 V

According to IEC/EN 60947-2, commonly used as a reference in professional and industrial applications, Schneider Electric specifies different ultimate breaking capacity Icu values depending on voltage:

  • 12-133 V AC: 42 kA.
  • 220-240 V AC: 30 kA.
  • 380-415 V AC: 15 kA.
  • 440 V AC: 10 kA.
  • Up to 125 V DC: 15 kA.

Therefore, on a 400 V network, the 15 kA value corresponds to Icu according to IEC/EN 60947-2, while the 10 kA value corresponds to Icn according to IEC/EN 60898-1.

Service breaking capacity Ics according to IEC/EN 60947-2

The main Ics values specified for the A9F89206 are:

  • 220-240 V AC: 15 kA.
  • 380-415 V AC: 7.5 kA.
  • 440 V AC: 5 kA.
  • Up to 125 V DC: 15 kA.

The required breaking capacity must be selected according to the maximum short-circuit current expected at the installation point.

Limitation class 3

The Acti9 iC60H has energy limiting class 3 according to IEC/EN 60898-1.

During a short circuit, the limiting capability reduces peak current and the energy passing through the circuit before disconnection is completed, reducing the thermal and electrodynamic stresses on downstream cables and equipment.

VisiTrip system

The VisiTrip technology makes it easy to visually identify a miniature circuit breaker that has tripped due to an electrical fault.

This indication helps quickly identify the affected outgoing circuit in panels with many circuits, reducing the time needed to locate the issue.

VisiSafe system

The VisiSafe system provides a reliable indication of the open contact position and helps improve safety during maintenance and circuit isolation operations.

The A9F89206 is also declared suitable for isolation according to IEC/EN 60898-1 and IEC/EN 60947-2.

Suitable for industrial isolation

Schneider Electric expressly specifies suitability for industrial isolation according to IEC/EN 60947-2.

This feature allows the miniature circuit breaker to be integrated into professional installations where a device suitable for isolating the circuit during certain service and maintenance tasks is required.

Use in AC and DC

The A9F89206 is specified for AC networks and certain DC applications.

In DC, Schneider Electric indicates an Icu breaking capacity of 15 kA up to 125 V DC.

When using the device in DC, the maximum voltage, configuration and connection conditions indicated by Schneider Electric must always be respected.

500 V insulation voltage

The main dielectric characteristics include:

  • Rated insulation voltage Ui: 500 V AC.
  • Impulse withstand voltage Uimp: 6 kV.
  • Utilization category: A according to IEC/EN 60947-2.
  • Overvoltage category: IV.
  • Pollution degree: 3.
  • Frequency: 50/60 Hz.

DIN rail mounting

The Schneider Electric A9F89206 is designed for fixed mounting on a DIN rail.

  • Mounting type: fixed.
  • Support: DIN rail.
  • 9 mm pitches: 4.
  • Modular width: 2 modules of 18 mm.

The modular format makes installation alongside other Acti9 protection, control and distribution devices easier.

Dimensions of the Acti9 iC60H A9F89206

  • Width: 36 mm.
  • Height: 85 mm.
  • Depth: 78.5 mm.
  • Weight: approximately 0.25 kg.
  • Color: white.

Its 36 mm width corresponds to two standard panel modules.

Terminals for rigid and flexible conductors

The terminals allow connection from the top or bottom.

  • Rigid conductor: 1 to 25 mm².
  • Flexible conductor: 1 to 16 mm².
  • Strip length: 14 mm.
  • Tightening torque: 2 Nm.

Correct terminal tightening is essential to prevent overheating and ensure a reliable electrical connection.

Compatible with distribution combs

The A9F89206 supports supply via combs or busbars compatible from both the top and bottom.

This makes it easier to assemble multiple Acti9 devices in modular panels and reduces the number of individual cable jumpers.

Compatible with auxiliaries and Vigi blocks

The Acti9 platform allows the iC60H to be complemented with different compatible accessories.

These may include:

  • Auxiliary contacts.
  • Trip indication contacts.
  • Auxiliary coils.
  • Remote monitoring devices.
  • Locking accessories.
  • Compatible Vigi residual current blocks.

The exact compatibility must be checked using the accessory reference and Schneider Electric tables.

Does not include residual current protection

The A9F89206 is a miniature circuit breaker. Its function is to protect the circuit against overloads and short circuits.

It does not itself include residual current protection against earth leakage. When the installation requires residual current protection, it can be combined with a compatible solution, such as a suitable Vigi block, or installed together with a correctly selected residual current device.

High durability

Schneider Electric specifies:

  • Mechanical durability: 20,000 cycles.
  • Electrical durability: 10,000 cycles.

These features are intended to provide a long service life when the device operates within its rated conditions.

IP20 protection rating

The miniature circuit breaker has an IP20 protection rating according to IEC/EN 60529.

It is intended to be installed inside a panel or enclosure that provides the environmental protection level required by the installation.

Environmental conditions

  • Operating ambient temperature: -35 to 70 °C.
  • Storage temperature: -40 to 85 °C.
  • Relative humidity: up to 95% at 55 °C.
  • Maximum operating altitude: 2,000 m.
  • Tropicalization: level 2 according to IEC 60068-1.

Applications of the Schneider Electric A9F89206

Thanks to its 6 A rated current and high breaking capacity, it can be used in low-current circuits where bipolar protection with a higher interruption capacity is required.

Possible applications include:

  • Auxiliary circuits.
  • Automation panels.
  • Control systems.
  • Commercial installations.
  • Tertiary installations.
  • Industrial panels.
  • Small loads and distribution lines.
  • Circuits with a rated current compatible with 6 A.

Technical characteristics of the Schneider Electric A9F89206

  • Brand: Schneider Electric.
  • Reference: A9F89206.
  • Range: Acti9.
  • Family: Acti9 iC60.
  • Model: iC60H.
  • Type: modular thermal-magnetic circuit breaker.
  • Application: electrical distribution.
  • Number of poles: 2P.
  • Protected poles: 2.
  • Rated current: 6 A.
  • Curve: C.
  • Technology: thermal-magnetic.
  • Magnetic threshold: 8 × In ±20 %.
  • Icn at 400 V AC according to IEC/EN 60898-1: 10 kA.
  • Ics at 400 V AC according to IEC/EN 60898-1: 7.5 kA.
  • Icu at 220-240 V AC: 30 kA.
  • Icu at 380-415 V AC: 15 kA.
  • Icu at 440 V AC: 10 kA.
  • Icu up to 125 V DC: 15 kA.
  • Ics at 220-240 V AC: 15 kA.
  • Ics at 380-415 V AC: 7.5 kA.
  • Ics at 440 V AC: 5 kA.
  • Limitation class: 3.
  • Network type: AC/DC.
  • Frequency: 50/60 Hz.
  • Utilization category: A.
  • Ui: 500 V AC.
  • Uimp: 6 kV.
  • Overvoltage category: IV.
  • Pollution degree: 3.
  • Suitable for isolation: yes.
  • Suitable for industrial isolation: yes.
  • VisiTrip: yes.
  • VisiSafe: yes.
  • Contact position indicator: yes.
  • Local trip indication: yes.
  • Actuator: toggle lever.
  • Mounting: DIN rail.
  • Width: 36 mm.
  • Height: 85 mm.
  • Depth: 78.5 mm.
  • Weight: approximately 0.25 kg.
  • Rigid conductor: 1-25 mm².
  • Flexible conductor: 1-16 mm².
  • Strip length: 14 mm.
  • Tightening torque: 2 Nm.
  • Protection rating: IP20.
  • Mechanical durability: 20,000 cycles.
  • Electrical durability: 10,000 cycles.
  • Operating temperature: -35 to 70 °C.
  • Storage temperature: -40 to 85 °C.
  • Maximum altitude: 2,000 m.
  • Integrated residual current protection: no.
  • Standards: IEC/EN 60898-1 and IEC/EN 60947-2.
  • EAN: 3606480095016.

High breaking capacity iC60H miniature circuit breaker

The Schneider Electric Acti9 iC60H A9F89206 combines a 6 A rated current, two protected poles and C curve with a high breaking capacity of 10 kA at 400 V according to IEC/EN 60898-1 and 15 kA Icu at 380-415 V according to IEC/EN 60947-2. This makes it a suitable option for panels where the expected short-circuit level requires higher performance than lower-capacity ranges can offer.

VisiTrip and VisiSafe technologies, compatibility with Acti9 auxiliaries, the possibility of adding Vigi residual current protection and its two-module format make it easy to create compact and easily monitored protection systems.

Important: before installing the A9F89206, the circuit design current, conductor cross-section, C curve, minimum and maximum short-circuit current and required breaking capacity must be verified. The device does not include integrated residual current protection, so residual protection must be added when required by the installation.

Specifications
Manufacturer
SCHNEIDER ELECTRIC
Reference
A9F89206
SKU
SCH18B31932
Object
Magnetic circuit breaker
Number of poles
Assembly
Fixed
Nominal current
6 A
Network type
CA, CC
Protection rating
IP20
Frequency
50.00 - 60.00 Hz
Datasheets
Reviews
Returns within 30 days
Shop with peace of mind. If something goes wrong, we'll take care of it.
After-sales service
Any questions? Our support team will be happy to help you.
Pay how and when you want
Card, bank transfer, PayPal... Installment? We have them all.
GroupSumi is your online distributor for construction, electrical material and climate control.
All rights reserved © 2026 GroupSumi