IC60N 2P 40A D Curve Circuit Breaker with reference A9F75240 from the brand SCHNEIDER ELECTRIC
IC60N 2P 40A D Curve Circuit Breaker with reference A9F75240 from the brand SCHNEIDER ELECTRIC
SCHNEIDER ELECTRIC

IC60N 2P 40A D Curve Circuit Breaker

REF
A9F75240
(0)
91.90 €
€91.90
€428.28
Up to -6% for professionals. Discover it.
Schneider Electric Acti9 iC60N 2P 40A D curve miniature circuit breaker, 6 kA breaking capacity, VisiTrip and VisiSafe, for protection of circuits with high inrush currents.
Buy now and receive it between November 27 and December 1
Get +92 +184 Sumis for the purchase
Receive 2x Sumis for a limited time
More about the product

Information about IC60N 2P 40A D Curve Circuit Breaker

The Schneider Electric Acti9 iC60N A9F75240 miniature circuit breaker is a bipolar automatic circuit breaker rated at 40 A with D curve, designed to protect electrical circuits against overloads and short circuits. It features 2 protected poles, thermal-magnetic tripping technology, and a rated breaking capacity of 6 kA at 400 V AC according to IEC/EN 60898-1. Its D curve is especially suitable for circuits with high inrush currents, such as motors, transformers, and certain inductive loads.

This miniature circuit breaker belongs to the Schneider Electric Acti9 iC60N range and incorporates VisiTrip and VisiSafe technologies, developed to make tripping easier to identify and to increase safety during maintenance operations. Its 2-pole modular format allows DIN rail installation in residential, commercial, and professional electrical panels.

40 A bipolar miniature circuit breaker with D curve

Reference A9F75240 features 2 poles and protection on both poles. Its rated current is 40 A and it uses a D tripping curve with a magnetic threshold of 12 times the rated current, with a tolerance of ±20%.

The D curve is especially suitable for circuits whose loads may generate significant current peaks during startup. This helps reduce nuisance tripping in properly sized applications with motors, transformers, and other equipment with high inrush currents.

  • Rated current: 40 A.
  • Number of poles: 2P.
  • Protected poles: 2.
  • Tripping curve: D.
  • Magnetic threshold: 12 x In ±20%.
  • Trip unit: thermal-magnetic.
  • Network type: AC and DC.
  • Frequency: 50/60 Hz.

Protection against overloads and short circuits

The Schneider Electric iC60N combines two tripping mechanisms. Thermal protection responds to sustained overloads that could cause excessive heating in the circuit, while magnetic protection acts quickly when a high short-circuit current occurs.

In this way, the A9F75240 provides comprehensive protection against the main overcurrents that can occur in an electrical circuit.

6 kA breaking capacity according to IEC/EN 60898-1

The miniature circuit breaker has a rated breaking capacity Icn of 6,000 A at 400 V AC in accordance with IEC/EN 60898-1. According to IEC/EN 60947-2, its ultimate breaking capacity Icu depends on the operating voltage.

  • Icn at 400 V AC according to IEC/EN 60898-1: 6 kA.
  • Icu at 12-133 V AC according to IEC/EN 60947-2: 36 kA.
  • Icu at 220-240 V AC according to IEC/EN 60947-2: 20 kA.
  • Icu at 380-415 V AC according to IEC/EN 60947-2: 10 kA.
  • Icu at 440 V AC according to IEC/EN 60947-2: 6 kA.
  • Icu up to 125 V DC according to IEC/EN 60947-2: 10 kA.
  • Limitation class: 3 according to IEC/EN 60898-1.

D curve for loads with high starting current

The main difference between this model and versions with B or C curves is its D tripping curve. Magnetic tripping occurs at higher currents, allowing the inrush current peaks typical of certain loads during startup to be tolerated.

For this reason, it is especially useful in circuits for equipment such as electric motors, transformers, machinery, or inductive loads. The selection of a D curve should be made taking into account the characteristics of the circuit, the impedance of the installation, and the tripping conditions required by the applicable regulations.

VisiTrip for quickly locating the affected circuit

The VisiTrip system from Schneider Electric includes a visual trip indication that makes it possible to quickly identify the device that has operated due to an electrical fault.

This function is especially practical in panels with numerous circuits, as it makes diagnosis easier and helps reduce the time needed to locate the tripped protection device.

VisiSafe to check contact opening

The VisiSafe technology provides a visual indication that allows the physical opening of the contacts to be checked. The green signal makes downstream maintenance work easier and contributes to a clearer identification of the circuit status.

The A9F75240 is also suitable for isolation in accordance with IEC/EN 60898-1 and IEC/EN 60947-2.

Electrical insulation and impulse withstand

The Acti9 iC60N A9F75240 has a rated insulation voltage Ui of 500 V AC and a rated impulse withstand voltage Uimp of 6 kV. It also features overvoltage category IV and pollution degree 3.

  • Rated insulation voltage Ui: 500 V AC.
  • Rated impulse withstand voltage Uimp: 6 kV.
  • Overvoltage category: IV.
  • Pollution degree: 3.
  • Utilization category: A according to IEC/EN 60947-2.

Compatible with auxiliaries and Vigi residual current blocks

The Acti9 platform allows the miniature circuit breaker to be complemented with electrical auxiliaries, signaling devices, and remote monitoring. It can also be combined with a compatible Vigi residual current block when the installation requires residual current protection.

The residual current block is a separate component and must be selected according to the number of poles, rated current, sensitivity, and the required type of residual current protection.

DIN rail mounting

The Schneider Electric A9F75240 is designed for fixed mounting on a 35 mm DIN rail. It can be connected from the top or bottom and is compatible with comb busbar systems and compatible distribution blocks from the Acti9 range.

Its bipolar format occupies 4 x 9 mm modules, equivalent to a total width of 36 mm or 2 standard 18 mm modules.

Compact dimensions

  • Height: 85 mm.
  • Width: 36 mm.
  • Depth: 78.5 mm.
  • Installation depth: 44.5 mm.
  • Weight: approximately 0.25 kg.
  • Modular width: 4 x 9 mm modules.
  • Color: white.

Conductor connection

The circuit breaker terminals accept rigid and flexible conductors of different cross-sections, making it easy to integrate into properly sized distribution circuits.

  • Rigid conductor: 1 to 35 mm².
  • Flexible conductor: 1 to 25 mm².
  • Strip length: 14 mm.
  • Tightening torque: 3.5 Nm.
  • Connection: top or bottom.

High electrical and mechanical durability

The Acti9 iC60N is designed to offer a long service life in electrical panels subject to regular switching operations. Reference A9F75240 achieves a mechanical durability of up to 20,000 cycles and an electrical durability of up to 10,000 cycles.

The power loss indicated for this model is approximately 3.6 W.

IP20 protection and wide temperature range

The miniature circuit breaker offers an IP20 protection rating as a standalone device and can reach IP40 when installed inside a suitable modular enclosure.

  • Device protection rating: IP20.
  • Protection in modular enclosure: up to IP40.
  • Operating ambient temperature: -35 to 70 °C.
  • Storage temperature: -40 to 85 °C.
  • Relative humidity: up to 95% at 55 °C.
  • Maximum operating altitude: 2,000 m.

Technical characteristics of Schneider Electric A9F75240

  • Brand: Schneider Electric.
  • Range: Acti9.
  • Series: iC60N.
  • Reference: A9F75240.
  • Type: thermal-magnetic circuit breaker.
  • Application: electrical distribution.
  • Number of poles: 2P.
  • Protected poles: 2.
  • Rated current: 40 A.
  • Curve: D.
  • Trip unit: thermal-magnetic.
  • Magnetic threshold: 12 x In ±20%.
  • Network type: AC/DC.
  • Frequency: 50/60 Hz.
  • Icn at 400 V according to IEC/EN 60898-1: 6 kA.
  • Icu at 380-415 V according to IEC/EN 60947-2: 10 kA.
  • Icu at 220-240 V according to IEC/EN 60947-2: 20 kA.
  • Icu at 440 V according to IEC/EN 60947-2: 6 kA.
  • Limitation class: 3.
  • Insulation voltage Ui: 500 V AC.
  • Impulse withstand voltage Uimp: 6 kV.
  • VisiTrip: yes.
  • VisiSafe: yes.
  • Suitable for isolation: yes.
  • Compatible with Acti9 auxiliaries: yes.
  • Residual current protection: via compatible independent Vigi block.
  • Rigid conductor: 1-35 mm².
  • Flexible conductor: 1-25 mm².
  • Tightening torque: 3.5 Nm.
  • Mounting: 35 mm DIN rail.
  • Dimensions: 85 x 36 x 78.5 mm.
  • Weight: 0.25 kg.
  • Mechanical durability: 20,000 cycles.
  • Electrical durability: 10,000 cycles.
  • Protection rating: IP20, up to IP40 in enclosure.
  • Operating temperature: -35 to 70 °C.
  • Standards: IEC/EN 60898-1 and IEC/EN 60947-2.

The Schneider Electric Acti9 iC60N A9F75240 2-pole, 40 A, D-curve miniature circuit breaker provides protection against overloads and short circuits in installations with loads that may present high starting currents. Its 6 kA breaking capacity according to IEC/EN 60898-1, 10 kA Icu at 380-415 V according to IEC/EN 60947-2, VisiTrip and VisiSafe technologies, and compatibility with Acti9 auxiliaries make it a robust solution for professional electrical panels.

Specifications
Manufacturer
SCHNEIDER ELECTRIC
Reference
A9F75240
SKU
SCH194AF9D2
Object
Magnetic circuit breaker
Number of poles
Assembly
Fixed
Nominal current
40 A
Network type
CA, CC
Protection rating
IP20
Frequency
50.00 - 60.00 Hz
Datasheets
Reviews
Returns within 30 days
Shop with peace of mind. If something goes wrong, we'll take care of it.
After-sales service
Any questions? Our support team will be happy to help you.
Pay how and when you want
Card, bank transfer, PayPal... Installment? We have them all.
GroupSumi is your online distributor for construction, electrical material and climate control.
All rights reserved © 2026 GroupSumi