IC60N 3P 40A Curve D Circuit Breaker with reference A9F75340 from the brand SCHNEIDER ELECTRIC
IC60N 3P 40A Curve D Circuit Breaker with reference A9F75340 from the brand SCHNEIDER ELECTRIC
SCHNEIDER ELECTRIC

IC60N 3P 40A Curve D Circuit Breaker

REF
A9F75340
(0)
Free shipping
150.50 €
€150.50
€651.63
Up to -11% for professionals. Discover it.
Schneider Electric Acti9 iC60N 3P 40A D curve miniature circuit breaker, 6 kA breaking capacity, thermal-magnetic protection, VisiTrip and VisiSafe for professional electrical panels.
Buy now and receive it between 20 and November 23
Express free delivery
Get +151 +301 Sumis for the purchase
Receive 2x Sumis for a limited time
More about the product

Information about IC60N 3P 40A Curve D Circuit Breaker

The Schneider Electric Acti9 iC60N A9F75340 miniature circuit breaker is a 3-pole, 40 A, D-curve automatic circuit breaker designed to protect electrical circuits against overloads and short circuits. Its tripping curve is especially suitable for installations with loads that can generate high inrush currents, such as motors, transformers, and other inductive loads, offering a robust solution for residential, commercial, and industrial electrical panels.

Reference A9F75340 belongs to the Schneider Electric Acti9 iC60N range and features all three poles protected by thermal-magnetic technology. It offers a rated breaking capacity of 6 kA at 400 V AC according to IEC/EN 60898-1 and an ultimate breaking capacity of 10 kA at 380-415 V AC according to IEC/EN 60947-2.

Three-phase 40 A miniature circuit breaker with D curve

The Schneider Electric A9F75340 has 3 protected poles and a rated current of 40 A. Its D curve features a high magnetic tripping threshold, approximately between 10 and 14 times the rated current according to the characteristics of the iC60 range, making it suitable for circuits where significant current surges occur during startup.

This feature helps reduce nuisance tripping in loads with high starting currents, provided that the selection of the breaker and conductors is made in accordance with the installation’s protection calculations and requirements.

  • Number of poles: 3P.
  • Number of protected poles: 3.
  • Rated current: 40 A.
  • Tripping curve: D.
  • Tripping technology: thermal-magnetic.
  • Frequency: 50/60 Hz.
  • Network type: AC and DC.

Thermal-magnetic protection against overloads and short circuits

The iC60N combines two protection functions in a single device. The thermal part acts against sustained overloads that could cause excessive heating of the conductors, while the magnetic trip provides rapid operation against high short-circuit currents.

In this way, the A9F75340 protects lines and loads against two of the main overcurrent situations that can occur in an electrical installation.

6 kA breaking capacity according to IEC/EN 60898-1

Schneider Electric specifies for this reference a rated breaking capacity Icn of 6,000 A at 400 V AC in accordance with IEC/EN 60898-1.

According to IEC/EN 60947-2, the ultimate breaking capacity Icu depends on the circuit voltage:

  • 12-133 V AC: 36 kA.
  • 220-240 V AC: 20 kA.
  • 380-415 V AC: 10 kA.
  • 440 V AC: 6 kA.

For 6 to 63 A ratings in the iC60N range, the service breaking capacity Ics reaches 75% of Icu under the conditions indicated by IEC/EN 60947-2.

VisiTrip for quick identification of the tripped circuit

The VisiTrip system makes electrical panel maintenance easier through a visible mechanical indicator on the front of the breaker. When the miniature circuit breaker trips due to an electrical fault, this signal allows the affected device to be identified quickly.

This function is especially useful in panels with numerous circuits, as it helps the installer locate the protection that has operated and reduces the time needed for troubleshooting.

VisiSafe to verify contact opening

Schneider Electric’s VisiSafe technology provides positive indication of contact opening. The appearance of the green band on the operating handle allows visual verification that the contacts are physically open under the conditions established by the manufacturer.

The A9F75340 is also suitable for industrial isolation according to IEC/EN 60947-2, a particularly relevant feature during interventions and maintenance operations.

Electrical isolation and surge withstand capability

The miniature circuit breaker has a rated insulation voltage Ui of 500 V and a rated impulse withstand voltage Uimp of 6 kV.

  • Rated insulation voltage Ui: 500 V.
  • Rated impulse withstand voltage Uimp: 6 kV.
  • Overvoltage category: IV.
  • Pollution degree: 3.

These characteristics make the device suitable for low-voltage installations that require a high level of insulation and resistance to transient overvoltages.

Compatible with auxiliaries and Vigi residual current protection

One of the advantages of the Schneider Electric Acti9 platform is its modular design. The iC60N A9F75340 supports the addition of different electrical auxiliaries for signaling, tripping, and remote monitoring functions.

It can also be combined with compatible Vigi iC60 residual current blocks, allowing residual current protection to be added when required by the installation design.

DIN rail installation

The Schneider Electric A9F75340 is designed for fixed mounting using a clip on a 35 mm DIN rail. It can be supplied from the top or bottom and is compatible with Acti9 comb busbar systems.

Its double-clip system makes it easy to remove the breaker even when installed alongside a compatible distribution comb, simplifying replacement and maintenance operations inside the panel.

Compact 3-module format

As a three-pole miniature circuit breaker, the device occupies 6 x 9 mm pitches, equivalent to 54 mm or 3 standard 18 mm modules.

  • Height: 85 mm.
  • Width: 54 mm.
  • Depth: 78.5 mm.
  • Installation depth: 44.5 mm.
  • Weight: approximately 0.375 kg.
  • Modular width: 6 x 9 mm pitches.
  • Mounting: 35 mm DIN rail.

Conductor connection up to 35 mm²

The terminals allow conductors to be connected from either the top or the bottom. The A9F75340 accepts suitable cross-sections for properly sized 40 A power circuits.

  • Rigid conductor: 1 to 35 mm².
  • Flexible conductor: 1 to 25 mm².
  • Strip length: 14 mm.
  • Tightening torque: 3.5 Nm.

High electrical and mechanical durability

The Acti9 iC60N is designed to withstand a high number of operations throughout its service life. The device offers mechanical durability of up to 20,000 cycles and electrical durability of up to 10,000 cycles under the conditions specified by Schneider Electric.

The power loss indicated for this reference is approximately 3.6 W.

IP20 protection and wide temperature range

The miniature circuit breaker has an IP20 protection rating as a standalone device and is designed to operate within a wide ambient temperature range.

  • Protection rating: IP20.
  • Operating temperature: -35 to 70 °C.
  • Storage temperature: -40 to 85 °C.
  • Maximum operating altitude: 2,000 m.

Technical characteristics of the Schneider Electric A9F75340

  • Brand: Schneider Electric.
  • Range: Acti9.
  • Series: iC60N.
  • Reference: A9F75340.
  • Type: thermal-magnetic circuit breaker.
  • Application: electrical circuit distribution and protection.
  • Number of poles: 3P.
  • Protected poles: 3.
  • Rated current: 40 A.
  • Curve: D.
  • Trip unit: thermal-magnetic.
  • Frequency: 50/60 Hz.
  • Network type: AC/DC.
  • Breaking capacity Icn at 400 V according to IEC/EN 60898-1: 6 kA.
  • Breaking capacity Icu at 380-415 V according to IEC/EN 60947-2: 10 kA.
  • Breaking capacity Icu at 220-240 V: 20 kA.
  • Breaking capacity Icu at 440 V: 6 kA.
  • Rated insulation voltage Ui: 500 V.
  • Rated impulse withstand voltage Uimp: 6 kV.
  • Overvoltage category: IV.
  • Pollution degree: 3.
  • VisiTrip: yes.
  • VisiSafe: yes.
  • Suitable for industrial isolation: yes.
  • Compatible with Acti9 auxiliaries: yes.
  • Compatible with Vigi blocks: yes.
  • Rigid conductor: 1-35 mm².
  • Flexible conductor: 1-25 mm².
  • Tightening torque: 3.5 Nm.
  • Protection rating: IP20.
  • Mechanical durability: 20,000 cycles.
  • Electrical durability: 10,000 cycles.
  • Mounting: 35 mm DIN rail.
  • Dimensions: 85 x 54 x 78.5 mm.
  • Approximate weight: 0.375 kg.
  • Operating temperature: -35 to 70 °C.
  • Standards: IEC/EN 60898-1 and IEC/EN 60947-2.

The Schneider Electric Acti9 iC60N A9F75340 3-pole, 40 A, D-curve miniature circuit breaker is a particularly suitable solution for protecting three-phase circuits with loads that present high inrush currents. Its 6 kA breaking capacity according to IEC/EN 60898-1 and 10 kA at 380-415 V according to IEC/EN 60947-2, together with VisiTrip and VisiSafe technologies and the possibility of adding auxiliaries and Vigi residual current protection, make it a complete option for professional electrical panels.

Specifications
Manufacturer
SCHNEIDER ELECTRIC
Reference
A9F75340
SKU
SCHCF3739BF
Object
Magnetic circuit breaker
Number of poles
Assembly
Fixed
Nominal current
40 A
Network type
CA, CC
Protection rating
IP20
Frequency
50.00 - 60.00 Hz
Datasheets
Reviews
Returns within 30 days
Shop with peace of mind. If something goes wrong, we'll take care of it.
After-sales service
Any questions? Our support team will be happy to help you.
Pay how and when you want
Card, bank transfer, PayPal... Installment? We have them all.
GroupSumi is your online distributor for construction, electrical material and climate control.
All rights reserved © 2026 GroupSumi