Schneider Electric Acti9 iC60N 4P 25 A D-curve thermal-magnetic circuit breaker, 6 kA at 400 V and 10 kA Icu at 380-415 V, with VisiTrip and VisiSafe to protect against overloads and short circuits.
Buy now and receive it between 20 and November 23
Express free delivery
Get +160 +319 Sumis for the purchase
Receive 2x Sumis for a limited time
More about the product

Information about IC60N 4P 25A Circuit Breaker Curve D

The Schneider Electric Acti9 iC60N A9F75425 thermal-magnetic circuit breaker is a modular automatic switch with 4 protected poles, 25 A and D curve, designed to protect electrical circuits against overloads and short circuits. It offers a rated breaking capacity Icn of 6 kA at 400 V AC according to IEC/EN 60898-1 and an ultimate breaking capacity Icu of 10 kA at 380-415 V AC according to IEC/EN 60947-2. Its D curve makes it suitable for loads with high inrush currents, while the VisiTrip and VisiSafe technologies make it easier to identify tripping and verify the safe status of the circuit.

Reference A9F75425 belongs to Schneider Electric's Acti9 iC60N range and combines thermal-magnetic tripping, class 3 current limiting, suitability for isolation and DIN rail mounting. Its four-pole configuration and compatibility with auxiliaries and Vigi residual current blocks allow it to be integrated into professional distribution boards, tertiary installations and industrial applications with loads that require a D tripping curve.

4-pole, 25 A thermal-magnetic circuit breaker

The Schneider Electric A9F75425 features 4 poles and 4 protected poles. This means that the four conductors connected to the breaker are protected against overcurrents and are disconnected together when the device operates.

  • Number of poles: 4P.
  • Protected poles: 4.
  • Rated current In: 25 A.
  • Tripping curve: D.
  • Tripping technology: thermal-magnetic.

Thermal-magnetic protection against overloads and short circuits

The Acti9 iC60N combines two protection principles:

  • Thermal protection: acts against sustained overloads that can cause excessive heating of the conductors.
  • Magnetic protection: provides rapid disconnection when a high short-circuit current occurs.

In this way, the A9F75425 protects the circuit against the main risks caused by overcurrent.

D curve for high inrush currents

Schneider Electric specifies a magnetic tripping threshold of 12 × In ±20 % for this reference.

The D curve allows it to tolerate higher inrush current peaks than B or C curve devices, so it may be suitable, subject to installation calculations, for loads such as:

  • Motors with high starting current.
  • Transformers.
  • Compressors.
  • Industrial machinery.
  • Equipment with significant transient currents.
  • Certain inductive loads.

Due to its high magnetic threshold, it is especially important to check that the minimum available fault current is sufficient to ensure disconnection within the required times.

6 kA according to IEC/EN 60898-1

In accordance with IEC/EN 60898-1, the A9F75425 has a rated breaking capacity Icn of 6,000 A at 400 V AC and 50/60 Hz.

The service breaking capacity Ics at 400 V according to the same standard is also 6 kA, equivalent to 100% of Icn.

10 kA Icu at 380-415 V according to IEC/EN 60947-2

When evaluated according to IEC/EN 60947-2, the breaking capacity depends on the network voltage:

  • 220-240 V AC: Icu of 20 kA.
  • 380-415 V AC: Icu of 10 kA.
  • 440 V AC: Icu of 6 kA.
  • 12-133 V AC: Icu of 36 kA.
  • Up to 250 V DC: Icu of 10 kA.

Therefore, the commercial values of 6 kA and 10 kA are both correct, but they correspond to different standards and test conditions.

Service breaking capacity Ics

According to IEC/EN 60947-2, Schneider Electric specifies:

  • 220-240 V AC: Ics of 15 kA.
  • 380-415 V AC: Ics of 7.5 kA.
  • 440 V AC: Ics of 4.5 kA.
  • Up to 250 V DC: Ics of 10 kA.

Class 3 current limiting

The iC60N A9F75425 has energy limiting class 3 according to IEC/EN 60898-1.

This capability limits the energy passing through the installation during a short circuit, reducing thermal and electrodynamic stress on downstream conductors and equipment.

VisiTrip for quick identification of the tripped circuit

The VisiTrip technology provides local indication that makes it easy to locate the circuit breaker that has operated due to a fault.

This function is especially useful in boards with numerous circuits, as it reduces the time needed to identify the tripped protection device.

VisiSafe for checking opening status

The VisiSafe system provides a contact position indication that allows you to visually confirm that the circuit is open.

In addition, the A9F75425 is declared suitable for isolation in accordance with IEC/EN 60898-1 and IEC/EN 60947-2.

Fast Closing technology

The Acti9 iC60 range uses a Fast Closing mechanism, which makes the contact closing speed independent of how quickly the operating lever is manually actuated.

This feature helps provide consistent switching and reduce contact wear.

Main electrical characteristics

  • Rated current: 25 A.
  • Number of poles: 4P.
  • Protected poles: 4.
  • Curve: D.
  • Magnetic threshold: 12 × In ±20 %.
  • Frequency: 50/60 Hz.
  • Network type: AC and DC within the specified conditions.
  • Rated insulation voltage Ui: 500 V AC.
  • Impulse withstand voltage Uimp: 6 kV.
  • Utilization category: A.
  • Overvoltage category: IV.
  • Pollution degree: 3.

DIN rail mounting

The Schneider Electric A9F75425 is designed for fixed mounting on a DIN rail, making it easy to integrate with other Acti9 modular devices.

  • Width: 72 mm.
  • Height: 85 mm.
  • Depth: 78.5 mm.
  • 9 mm pitches: 8.
  • Equivalent: 4 modules of 18 mm.
  • Weight: approximately 0.5 kg.
  • Color: white.

Top or bottom connection

The terminals allow connection from the top or bottom and accept compatible distribution combs.

  • Rigid conductor: 1-25 mm².
  • Flexible conductor: 1-16 mm².
  • Strip length: 14 mm.
  • Tightening torque: 2 Nm.

Compatible with Acti9 auxiliaries

The iC60N can be complemented with different compatible accessories to expand the functions of the board:

  • Auxiliary contacts.
  • Trip signaling contacts.
  • Auxiliary release coils.
  • Remote monitoring devices.
  • Locking accessories.
  • Distribution combs.
  • Compatible Vigi residual current blocks.

The exact compatibility should be checked according to the specific accessory reference.

Does not include residual current protection

The A9F75425 is a thermal-magnetic circuit breaker. Its function is to protect against overloads and short circuits.

It does not itself include residual current protection against earth leakage. When required by the installation, it must be combined with a compatible Vigi block or with a properly selected residual current protection device.

Mechanical and electrical durability

  • Mechanical durability: 20,000 cycles.
  • Electrical durability: 10,000 cycles.

These ratings make the device suitable for professional boards subject to normal switching, disconnection and maintenance operations.

IP20 protection rating

The A9F75425 has an IP20 protection rating in accordance with IEC 60529.

It must be installed inside a suitable enclosure or panel that provides the environmental protection level required for the application.

Environmental conditions

  • Operating temperature: -35 to 70 °C.
  • Storage temperature: -40 to 85 °C.
  • Relative humidity: up to 95% at 55 °C.
  • Operating altitude: up to 2,000 m.

Applications of the Schneider Electric A9F75425

With its 25 A rating and D curve, this reference is especially suitable for circuits that may present high starting currents, provided that protection calculations confirm its suitability.

  • Motors.
  • Transformers.
  • Pumps.
  • Compressors.
  • Industrial machinery.
  • Automation panels.
  • Inductive loads with high inrush peaks.
  • Three-phase circuits requiring four protected poles.

Technical characteristics of the Schneider Electric A9F75425

  • Brand: Schneider Electric.
  • Reference: A9F75425.
  • Range: Acti9.
  • Family: iC60.
  • Model: iC60N.
  • Type: modular thermal-magnetic circuit breaker.
  • Number of poles: 4P.
  • Protected poles: 4.
  • Rated current: 25 A.
  • Curve: D.
  • Tripping technology: thermal-magnetic.
  • Magnetic threshold: 12 × In ±20 %.
  • Icn at 400 V AC according to IEC/EN 60898-1: 6 kA.
  • Icu at 220-240 V AC: 20 kA.
  • Icu at 380-415 V AC: 10 kA.
  • Icu at 440 V AC: 6 kA.
  • Icu up to 250 V DC: 10 kA.
  • Ics at 380-415 V AC: 7.5 kA.
  • Limiting class: 3.
  • Frequency: 50/60 Hz.
  • Network type: AC/DC.
  • Ui: 500 V AC.
  • Uimp: 6 kV.
  • Utilization category: A.
  • Overvoltage category: IV.
  • VisiTrip: yes.
  • VisiSafe: yes.
  • Fast Closing: yes.
  • Suitable for isolation: yes.
  • Mounting: DIN rail.
  • Width: 72 mm.
  • Height: 85 mm.
  • Depth: 78.5 mm.
  • Weight: approximately 0.5 kg.
  • Rigid conductor: 1-25 mm².
  • Flexible conductor: 1-16 mm².
  • Strip length: 14 mm.
  • Tightening torque: 2 Nm.
  • Protection rating: IP20.
  • Mechanical durability: 20,000 cycles.
  • Electrical durability: 10,000 cycles.
  • Operating temperature: -35 to 70 °C.
  • Storage temperature: -40 to 85 °C.
  • Maximum altitude: 2,000 m.
  • Integrated residual current protection: no.
  • Standards: IEC/EN 60898-1 and IEC/EN 60947-2.
  • EAN: 3606480081125.

Four-pole protection for loads with strong starting peaks

The Schneider Electric Acti9 iC60N A9F75425 combines four protected poles, 25 A and D curve in a modular device designed for circuits with high inrush currents. Its breaking capacity reaches 6 kA Icn at 400 V according to IEC/EN 60898-1 and 10 kA Icu at 380-415 V according to IEC/EN 60947-2.

The VisiTrip, VisiSafe and Fast Closing technologies, together with compatibility with auxiliaries and Vigi blocks, make it easier to create professional distribution boards with improved diagnostics and maintenance.

Important: the D curve has a high magnetic threshold, so before using the A9F75425 you must check the design current, conductor cross-section, minimum and maximum short-circuit current, circuit impedance and required breaking capacity. This circuit breaker does not include residual current protection against earth leakage.

Specifications
Manufacturer
SCHNEIDER ELECTRIC
Reference
A9F75425
SKU
SCH93A6FDBA
Object
Magnetic circuit breaker
Number of poles
Assembly
Fixed
Nominal current
25 A
Network type
CA, CC
Protection rating
IP20
Frequency
50.00 - 60.00 Hz
Datasheets
Reviews
Returns within 30 days
Shop with peace of mind. If something goes wrong, we'll take care of it.
After-sales service
Any questions? Our support team will be happy to help you.
Pay how and when you want
Card, bank transfer, PayPal... Installment? We have them all.
GroupSumi is your online distributor for construction, electrical material and climate control.
All rights reserved © 2026 GroupSumi