IC60N 4P 40A Circuit Breaker Curve C 10kA with reference A9F79440 from the brand SCHNEIDER ELECTRIC
IC60N 4P 40A Circuit Breaker Curve C 10kA with reference A9F79440 from the brand SCHNEIDER ELECTRIC
SCHNEIDER ELECTRIC

IC60N 4P 40A Circuit Breaker Curve C 10kA

REF
A9F79440
(0)
82.40 €
€82.40
€444.71
Up to -6% for professionals. Discover it.
Schneider Electric Acti9 iC60N 4P 40A C-curve miniature circuit breaker, 6kA according to IEC 60898-1 and 10kA according to IEC 60947-2, 4 protected poles, VisiTrip, VisiSafe and DIN rail mounting.
Buy now and receive it between 20 and November 23
Express delivery
Get +83 +165 Sumis for the purchase
Receive 2x Sumis for a limited time
More about the product

Information about IC60N 4P 40A Circuit Breaker Curve C 10kA

The Schneider Electric Acti9 iC60N A9F79440 circuit breaker is a modular 4-pole, 40 A, C-curve miniature circuit breaker designed to protect electrical circuits against overloads and short circuits. Its four poles are protected by thermal-magnetic tripping technology and it offers a breaking capacity of 6 kA according to IEC/EN 60898-1 and 10 kA at 380-415 V according to IEC/EN 60947-2.

It is part of Schneider Electric’s professional Acti9 iC60 range and is suitable for residential, commercial, and industrial electrical panels. It incorporates technologies such as VisiTrip to make tripped circuits easy to identify, VisiSafe to provide reliable indication of contact opening, and a fast-closing mechanism independent of manual operating speed.

Main features of the Schneider Electric A9F79440

  • Brand: Schneider Electric.
  • Range: Acti9.
  • Family: Acti9 iC60.
  • Model: iC60N.
  • Reference: A9F79440.
  • Type: modular thermal-magnetic circuit breaker.
  • Application: electrical protection and distribution.
  • Number of poles: 4P.
  • Protected poles: 4.
  • Rated current: 40 A.
  • Tripping curve: C.
  • Tripping technology: thermal-magnetic.
  • Network type: AC and DC within the specified limits.
  • Frequency: 50/60 Hz.
  • Icn at 400 V according to IEC/EN 60898-1: 6 kA.
  • Icu at 380-415 V according to IEC/EN 60947-2: 10 kA.
  • Icu at 220-240 V according to IEC/EN 60947-2: 20 kA.
  • Icu at 440 V according to IEC/EN 60947-2: 6 kA.
  • Limiting class: 3.
  • Utilization category: A.
  • Rated insulation voltage Ui: 500 V.
  • Impulse withstand voltage Uimp: 6 kV.
  • Suitable for isolation: yes.
  • VisiTrip: yes.
  • VisiSafe: yes.
  • Mounting: DIN rail.
  • Width: 72 mm.
  • Height: 85 mm.
  • Depth: 78.5 mm.
  • Weight: approximately 0.5 kg.

4-pole 40 A circuit breaker

The A9F79440 has a 4P configuration with all four poles protected. This design allows the four conductors of the circuit to be protected and disconnected simultaneously by a single device.

Its rated current of 40 A makes it suitable for lines correctly sized for this current. The selection of the circuit breaker must be made together with conductor cross-section, installation method, ambient temperature, voltage drop, and expected short-circuit current.

Protection against overloads and short circuits

The Acti9 iC60N uses a thermal-magnetic tripping system that combines two types of protection.

The thermal element acts against sustained overloads that can cause excessive heating of the conductors. The magnetic trip responds quickly to high currents produced by a short circuit.

In this way, the A9F79440 protects the installation against two of the main overcurrent situations that can occur in an electrical circuit.

C tripping curve

The A9F79440 reference uses a C curve. Schneider Electric specifies a magnetic tripping threshold of approximately 8 x In ±20%.

The C curve is common in general distribution circuits and allows certain transient inrush currents without nuisance tripping, provided the installation and load are compatible.

6 kA according to IEC/EN 60898-1

According to the IEC/EN 60898-1 standard, Schneider Electric specifies for this reference a rated breaking capacity Icn of 6000 A at 400 V AC.

This is the value to use when the device is evaluated according to this standard for circuit breakers intended for domestic and similar installations.

10 kA according to IEC/EN 60947-2 at 380-415 V

According to the industrial IEC/EN 60947-2 standard, the ultimate breaking capacity Icu of the A9F79440 varies depending on voltage:

  • 220-240 V AC: 20 kA.
  • 380-415 V AC: 10 kA.
  • 440 V AC: 6 kA.
  • Up to 250 V DC: 10 kA.

For this reason, the commercial designation 6 kA / 10 kA is not contradictory: the two values correspond to different standards and test conditions.

Limiting class 3

The iC60N belongs to limiting class 3 according to IEC/EN 60898-1. Current limiting capability helps reduce the energy that passes through the circuit during certain short circuits.

Lower let-through energy reduces the thermal and electrodynamic stresses imposed on downstream conductors and equipment.

VisiTrip technology

The Acti9 iC60 range includes VisiTrip, a front indicator designed to make it easy to identify a circuit that has tripped due to an electrical fault.

This indication can reduce the time needed to locate the protection device that has operated within a panel with many circuits.

VisiSafe technology

The VisiSafe system provides a visual indication associated with the physical opening of the contacts.

This function is intended to increase safety during downstream maintenance operations on the circuit breaker, always respecting the required lockout and absence-of-voltage verification procedures.

Fast-closing mechanism

The closing mechanism of the Acti9 iC60N is designed so that the contact closing speed is independent of how quickly the user operates the lever.

This feature improves contact closing repeatability and contributes to the device’s electrical durability.

Suitable for isolation

The Schneider Electric A9F79440 is declared suitable for isolation or disconnection in accordance with IEC/EN 60898-1 and IEC/EN 60947-2.

In addition to protecting against overcurrents, it can form part of the circuit isolation functions within the conditions established by the manufacturer and applicable standards.

Dielectric characteristics

  • Rated insulation voltage Ui: 500 V AC.
  • Impulse withstand voltage Uimp: 6 kV.
  • Overvoltage category: IV.
  • Pollution degree: 3.

These characteristics allow the circuit breaker to be integrated into professional distribution panels within its rated operating conditions.

DIN rail mounting

The A9F79440 is installed by clip-on mounting on a symmetrical DIN rail, making installation, replacement, and integration with other modular Acti9 devices easier.

It occupies 8 x 9 mm pitches, equivalent to four standard 18 mm modules.

Dimensions

  • Width: 72 mm.
  • Height: 85 mm.
  • Depth: 78.5 mm.
  • Module width: 4 x 18 mm modules.
  • Weight: approximately 0.5 kg.
  • Color: RAL 9003 white.

Connection terminals

The circuit breaker uses upper and lower connection terminals suitable for copper conductors.

  • Rigid conductor: 1 to 35 mm².
  • Flexible conductor: 1 to 25 mm².
  • Strip length: 14 mm.
  • Tightening torque: 3.5 Nm.

The final conductor cross-section must be calculated according to design current, installation method, temperature, grouping, length, and applicable electrical regulations.

Compatible with distribution busbars

The modular design of Acti9 allows the A9F79440 to be integrated with distribution systems using compatible comb busbars or busbars, making it easier to supply multiple devices in an orderly way within the same panel.

Compatible with Acti9 auxiliaries

The iC60N can be complemented with different accessories and auxiliaries from the Acti9 range, allowing functions such as:

  • Auxiliary signaling.
  • Trip signaling.
  • Remote tripping.
  • Status monitoring.
  • Control elements.
  • Padlock locking.

Accessories must be selected by specifically checking their compatibility with the iC60 series.

Possibility of adding residual current protection

The A9F79440 is a circuit breaker and therefore its main function is protection against overloads and short circuits. It does not include residual current protection as standard.

When the installation requires protection against earth leakage currents, it can be combined with compatible residual current solutions, such as Vigi Acti9 blocks, or installed together with the appropriate residual current device.

Mechanical and electrical durability

Schneider Electric specifies for the iC60N range a high number of operating cycles:

  • Mechanical durability: up to 20,000 cycles.
  • Electrical durability: up to 10,000 cycles.

These features make it suitable for use in residential, commercial, and industrial panels with a long expected service life.

IP20 protection

The device has an IP20 protection rating according to IEC 60529.

When correctly installed inside a compatible enclosure, front protection can reach IP40, depending on the characteristics of the panel used.

Wide temperature range

The Acti9 iC60N is designed to operate over a wide temperature range:

  • Operating ambient temperature: -35 to +70 °C.
  • Storage temperature: -40 to +85 °C.
  • Relative humidity: up to 95% at 55 °C.

Applications of the Schneider Electric A9F79440

Thanks to its 4-pole configuration, 40 A rating, and C curve, it can be used in many correctly sized electrical distribution installations:

  • Main low-voltage switchboards.
  • Secondary distribution boards.
  • Three-phase installations with neutral.
  • Residential buildings.
  • Commercial premises.
  • Offices.
  • Commercial and tertiary installations.
  • HVAC panels.
  • Industrial installations.
  • Three-phase lines requiring simultaneous disconnection of four poles.

Applicable standards

The Schneider Electric A9F79440 is specified in accordance with:

  • IEC 60898-1.
  • EN 60898-1.
  • IEC 60947-2.
  • EN 60947-2.

Technical data of the Schneider Electric A9F79440

  • Manufacturer: Schneider Electric.
  • Reference: A9F79440.
  • EAN: 3606480093456.
  • Range: Acti9.
  • Product: Acti9 iC60.
  • Model: iC60N.
  • Type: thermal-magnetic circuit breaker.
  • Application: electrical distribution.
  • Poles: 4P.
  • Protected poles: 4.
  • Rated current: 40 A.
  • Curve: C.
  • Technology: thermal-magnetic.
  • Frequency: 50/60 Hz.
  • Magnetic threshold: 8 x In ±20%.
  • Icn at 400 V according to IEC/EN 60898-1: 6 kA.
  • Icu at 220-240 V according to IEC/EN 60947-2: 20 kA.
  • Icu at 380-415 V according to IEC/EN 60947-2: 10 kA.
  • Icu at 440 V according to IEC/EN 60947-2: 6 kA.
  • Icu up to 250 V DC: 10 kA.
  • Limiting class: 3.
  • Utilization category: A.
  • Ui: 500 V.
  • Uimp: 6 kV.
  • Suitable for isolation: yes.
  • VisiTrip: yes.
  • VisiSafe: yes.
  • Mounting: DIN rail.
  • 9 mm pitches: 8.
  • 18 mm modules: 4.
  • Width: 72 mm.
  • Height: 85 mm.
  • Depth: 78.5 mm.
  • Weight: approximately 0.5 kg.
  • Color: RAL 9003 white.
  • Rigid conductor: 1-35 mm².
  • Flexible conductor: 1-25 mm².
  • Strip length: 14 mm.
  • Tightening torque: 3.5 Nm.
  • Mechanical durability: 20,000 cycles.
  • Electrical durability: 10,000 cycles.
  • Protection: IP20.
  • Protection in suitable enclosure: up to IP40.
  • Operating temperature: -35 to +70 °C.
  • Storage temperature: -40 to +85 °C.
  • Integrated residual current protection: no.

Acti9 iC60N 4P 40 A circuit breaker for electrical distribution

The Schneider Electric A9F79440 combines four protected poles, 40 A rated current, and C curve in a modular device designed for demanding distribution installations. Its thermal-magnetic protection acts against overloads and short circuits, while its breaking capacity reaches 6 kA according to IEC/EN 60898-1 and 10 kA at 380-415 V according to IEC/EN 60947-2.

VisiTrip and VisiSafe technologies, suitability for isolation, terminals for rigid conductors up to 35 mm², compatibility with Acti9 auxiliaries, and high durability make it easy to integrate into residential, commercial, and industrial panels. For correct selection, always check the design current, conductor cross-section, tripping curve, and available short-circuit current at the installation point.

Specifications
Manufacturer
SCHNEIDER ELECTRIC
Reference
A9F79440
SKU
SCH7E19C301
Object
Magnetic circuit breaker
Number of poles
Assembly
Fixed
Nominal current
40 A
Network type
CA, CC
Protection rating
IP20
Frequency
50.00 - 60.00 Hz
Datasheets
Reviews
Returns within 30 days
Shop with peace of mind. If something goes wrong, we'll take care of it.
After-sales service
Any questions? Our support team will be happy to help you.
Pay how and when you want
Card, bank transfer, PayPal... Installment? We have them all.
GroupSumi is your online distributor for construction, electrical material and climate control.
All rights reserved © 2026 GroupSumi