The Schneider Electric Acti9 iC60N A9F79450 circuit breaker is a modular 4-pole, 50 A, C-curve miniature circuit breaker designed to protect electrical circuits against overloads and short circuits. All four poles are protected by thermal-magnetic tripping, and the device offers a rated breaking capacity of 6 kA according to IEC/EN 60898-1 and an ultimate breaking capacity of 10 kA at 380-415 V according to IEC/EN 60947-2.
It belongs to Schneider Electric's professional Acti9 iC60 range and is intended for residential, commercial and industrial electrical distribution installations. It incorporates the signalling and safety features typical of the Acti9 series, is suitable for isolation, accepts compatible auxiliaries and Vigi residual current blocks, and is installed directly on DIN rail.
The A9F79450 has four poles, all of them protected against overcurrent. This configuration allows simultaneous disconnection of the four circuit conductors using a single mechanism.
Its 50 A rated current makes it suitable for distribution lines designed for this current, provided that conductor cross-section, installation method and other electrical conditions are compatible.
The iC60N uses a thermal-magnetic trip unit. The thermal element responds to sustained overloads that can cause excessive heating of the conductors, while the magnetic trip acts quickly against high short-circuit currents.
This combination protects both the wiring and the connected equipment within the operating conditions defined by Schneider Electric.
The A9F79450 reference uses a C tripping curve. Schneider Electric specifies for the iC60N range a magnetic threshold of approximately 8 times the rated current with a tolerance of ±20 %.
The C curve is one of the most widely used in general distribution installations and is suitable for circuits that may present moderate inrush currents when certain loads are switched on.
According to IEC/EN 60898-1, this circuit breaker has a rated breaking capacity Icn of 6000 A.
This value must be compared with the prospective short-circuit current at the specific installation point to ensure the device has sufficient capacity to interrupt the fault.
When evaluated according to the industrial standard IEC/EN 60947-2, Schneider Electric specifies an ultimate breaking capacity Icu of 10 kA at 380-415 V AC.
For 220-240 V AC, the Icu reaches 20 kA. For this reason, the commercial product designation is often shown as 6 kA / 10 kA: both values are correct, but they correspond to different standards and test conditions.
The iC60N A9F79450 has limiting class 3 according to IEC/EN 60898-1.
The current-limiting capability reduces the energy flowing through the circuit during certain short circuits, helping to reduce the thermal and electrodynamic stresses on downstream conductors and equipment.
The Acti9 iC60 range incorporates the VisiSafe system, designed to provide reliable indication of contact position and improve safety during circuit intervention operations.
The device also includes local status and trip indication, making it easier to identify the affected circuit in panels with multiple protections.
Schneider Electric declares the A9F79450 as suitable for industrial isolation or disconnection according to IEC/EN 60947-2.
This feature allows the circuit breaker to be used both as a protection device and to electrically isolate the circuit within the conditions defined by the manufacturer and applicable regulations.
The main dielectric characteristics of the device are:
The A9F79450 is designed for clip-on installation on a 35 mm symmetrical DIN rail. It can be mounted in different positions inside the electrical panel.
It occupies 8 modules of 9 mm, equivalent to four standard 18 mm modules.
Its modular format allows it to be installed alongside residual current devices, contactors, surge protection devices and other Acti9 equipment inside distribution boards.
As this is a 50 A version, Schneider Electric specifies terminals capable of accepting:
Connections can be made from the top or bottom. The cross-section used must be determined according to design current, length, voltage drop, temperature, installation method and applicable regulations.
The iC60N is ready to integrate into distribution systems using Acti9 comb busbars, from either the top or bottom depending on the chosen configuration.
This makes it easier to simplify and organize power distribution among multiple devices inside the panel.
The modular Acti9 design allows the circuit breaker to be completed with different compatible accessories, such as:
The specific accessories must be selected by checking compatibility with the iC60 range.
The A9F79450 provides exclusively thermal-magnetic protection against overloads and short circuits. It does not include built-in residual current protection against earth leakage.
When the circuit requires residual current protection, Schneider Electric provides for association with a compatible Vigi block or another correctly sized Acti9 residual current solution.
Schneider Electric specifies high switching endurance:
These values make it suitable for professional panels where a long service life is required within its rated conditions.
The circuit breaker has an IP20 protection rating as a standalone device. When installed inside a suitable modular enclosure, the assembly can achieve higher protection ratings depending on the panel characteristics.
The Acti9 iC60 range is designed to operate in demanding environmental conditions:
Due to its 4-pole configuration and 50 A rating, this miniature circuit breaker can be used in applications such as:
The Schneider Electric A9F79450 is designed in accordance with the main standards applicable to modular circuit breakers:
The Schneider Electric A9F79450 combines four protected poles, a 50 A rating, C curve and thermal-magnetic protection in a modular device 72 mm wide. It offers 6 kA breaking capacity according to IEC/EN 60898-1 and 10 kA at 380-415 V according to IEC/EN 60947-2, making it suitable for residential and commercial panels as well as certain industrial applications.
Its suitability for isolation, compatibility with auxiliaries and Vigi blocks, terminals up to 35 mm² and high mechanical and electrical durability make it easy to integrate into professional distribution panels. To select the correct circuit breaker, the conductor cross-section, design current, tripping curve and prospective short-circuit current at the installation point must be verified.