Schneider Electric Acti9 iC60N 4P 50A C-curve miniature circuit breaker, 6kA according to IEC 60898-1 and 10kA according to IEC 60947-2, 4 protected poles, VisiSafe and DIN rail mounting.
Buy now and receive it between 20 and November 23
Express free delivery
Get +211 +422 Sumis for the purchase
Receive 2x Sumis for a limited time
More about the product

Information about IC60N 4P 50A Curve C 10kA Circuit Breaker

The Schneider Electric Acti9 iC60N A9F79450 circuit breaker is a modular 4-pole, 50 A, C-curve miniature circuit breaker designed to protect electrical circuits against overloads and short circuits. All four poles are protected by thermal-magnetic tripping, and the device offers a rated breaking capacity of 6 kA according to IEC/EN 60898-1 and an ultimate breaking capacity of 10 kA at 380-415 V according to IEC/EN 60947-2.

It belongs to Schneider Electric's professional Acti9 iC60 range and is intended for residential, commercial and industrial electrical distribution installations. It incorporates the signalling and safety features typical of the Acti9 series, is suitable for isolation, accepts compatible auxiliaries and Vigi residual current blocks, and is installed directly on DIN rail.

Key features of the Schneider Electric A9F79450

  • Brand: Schneider Electric.
  • Range: Acti9.
  • Family: Acti9 iC60.
  • Model: iC60N.
  • Reference: A9F79450.
  • Type: modular miniature circuit breaker.
  • Application: electrical distribution.
  • Number of poles: 4P.
  • Protected poles: 4.
  • Rated current: 50 A.
  • Tripping curve: C.
  • Tripping technology: thermal-magnetic.
  • Frequency: 50/60 Hz.
  • Icn according to IEC/EN 60898-1: 6 kA.
  • Icu at 380-415 V according to IEC/EN 60947-2: 10 kA.
  • Icu at 220-240 V according to IEC/EN 60947-2: 20 kA.
  • C-curve magnetic threshold: 8 x In ±20 %.
  • Limiting class: 3.
  • Rated insulation voltage Ui: 500 V.
  • Impulse withstand voltage Uimp: 6 kV.
  • Utilization category: A.
  • Suitable for isolation: yes.
  • Mounting: 35 mm DIN rail.
  • Width: 72 mm.
  • Height: 85 mm.
  • Depth: 78.5 mm.
  • Weight: approximately 0.5 kg.

4-pole 50 A protection

The A9F79450 has four poles, all of them protected against overcurrent. This configuration allows simultaneous disconnection of the four circuit conductors using a single mechanism.

Its 50 A rated current makes it suitable for distribution lines designed for this current, provided that conductor cross-section, installation method and other electrical conditions are compatible.

Protection against overloads and short circuits

The iC60N uses a thermal-magnetic trip unit. The thermal element responds to sustained overloads that can cause excessive heating of the conductors, while the magnetic trip acts quickly against high short-circuit currents.

This combination protects both the wiring and the connected equipment within the operating conditions defined by Schneider Electric.

C curve

The A9F79450 reference uses a C tripping curve. Schneider Electric specifies for the iC60N range a magnetic threshold of approximately 8 times the rated current with a tolerance of ±20 %.

The C curve is one of the most widely used in general distribution installations and is suitable for circuits that may present moderate inrush currents when certain loads are switched on.

6 kA according to IEC/EN 60898-1

According to IEC/EN 60898-1, this circuit breaker has a rated breaking capacity Icn of 6000 A.

This value must be compared with the prospective short-circuit current at the specific installation point to ensure the device has sufficient capacity to interrupt the fault.

10 kA according to IEC/EN 60947-2 at 380-415 V

When evaluated according to the industrial standard IEC/EN 60947-2, Schneider Electric specifies an ultimate breaking capacity Icu of 10 kA at 380-415 V AC.

For 220-240 V AC, the Icu reaches 20 kA. For this reason, the commercial product designation is often shown as 6 kA / 10 kA: both values are correct, but they correspond to different standards and test conditions.

Limiting class 3

The iC60N A9F79450 has limiting class 3 according to IEC/EN 60898-1.

The current-limiting capability reduces the energy flowing through the circuit during certain short circuits, helping to reduce the thermal and electrodynamic stresses on downstream conductors and equipment.

VisiSafe and status indication

The Acti9 iC60 range incorporates the VisiSafe system, designed to provide reliable indication of contact position and improve safety during circuit intervention operations.

The device also includes local status and trip indication, making it easier to identify the affected circuit in panels with multiple protections.

Suitable for isolation

Schneider Electric declares the A9F79450 as suitable for industrial isolation or disconnection according to IEC/EN 60947-2.

This feature allows the circuit breaker to be used both as a protection device and to electrically isolate the circuit within the conditions defined by the manufacturer and applicable regulations.

Ui of 500 V and Uimp of 6 kV

The main dielectric characteristics of the device are:

  • Rated insulation voltage Ui: 500 V AC.
  • Impulse withstand voltage Uimp: 6 kV.
  • Overvoltage category: IV.
  • Pollution degree: 3.

DIN rail mounting

The A9F79450 is designed for clip-on installation on a 35 mm symmetrical DIN rail. It can be mounted in different positions inside the electrical panel.

It occupies 8 modules of 9 mm, equivalent to four standard 18 mm modules.

Dimensions

  • Width: 72 mm.
  • Height: 85 mm.
  • Depth: 78.5 mm.
  • Weight: approximately 500 g.
  • Color: white.

Its modular format allows it to be installed alongside residual current devices, contactors, surge protection devices and other Acti9 equipment inside distribution boards.

Terminals for conductors up to 35 mm²

As this is a 50 A version, Schneider Electric specifies terminals capable of accepting:

  • Rigid copper conductor: 1 to 35 mm².
  • Flexible conductor: 1 to 25 mm².
  • Strip length: 14 mm.
  • Tightening torque: 3.5 Nm.

Connections can be made from the top or bottom. The cross-section used must be determined according to design current, length, voltage drop, temperature, installation method and applicable regulations.

Compatible with comb busbars

The iC60N is ready to integrate into distribution systems using Acti9 comb busbars, from either the top or bottom depending on the chosen configuration.

This makes it easier to simplify and organize power distribution among multiple devices inside the panel.

Option to add auxiliaries

The modular Acti9 design allows the circuit breaker to be completed with different compatible accessories, such as:

  • Auxiliary contacts.
  • Signalling contacts.
  • Auxiliary trip units.
  • Remote monitoring elements.
  • Control accessories.
  • Compatible Vigi residual current blocks.

The specific accessories must be selected by checking compatibility with the iC60 range.

Residual current protection via separate block

The A9F79450 provides exclusively thermal-magnetic protection against overloads and short circuits. It does not include built-in residual current protection against earth leakage.

When the circuit requires residual current protection, Schneider Electric provides for association with a compatible Vigi block or another correctly sized Acti9 residual current solution.

Mechanical and electrical durability

Schneider Electric specifies high switching endurance:

  • Mechanical endurance: 20,000 cycles.
  • Electrical endurance: 10,000 cycles.

These values make it suitable for professional panels where a long service life is required within its rated conditions.

IP20 protection

The circuit breaker has an IP20 protection rating as a standalone device. When installed inside a suitable modular enclosure, the assembly can achieve higher protection ratings depending on the panel characteristics.

Wide operating temperature range

The Acti9 iC60 range is designed to operate in demanding environmental conditions:

  • Operating temperature: -35 to +70 °C.
  • Storage temperature: -40 to +85 °C.
  • Relative humidity: up to 95% at 55 °C.
  • Operating altitude without additional corrections: up to 2000 m.

Applications of the Schneider Electric A9F79450

Due to its 4-pole configuration and 50 A rating, this miniature circuit breaker can be used in applications such as:

  • Main and sub-distribution boards.
  • Three-phase installations with neutral.
  • Residential buildings.
  • Commercial premises.
  • Offices and tertiary buildings.
  • Low-voltage industrial installations.
  • HVAC panels.
  • Distribution line protection.
  • Installations requiring simultaneous disconnection of four poles.

Applicable standards

The Schneider Electric A9F79450 is designed in accordance with the main standards applicable to modular circuit breakers:

  • IEC/EN 60898-1.
  • IEC/EN 60947-2.

Technical data of the Schneider Electric A9F79450

  • Manufacturer: Schneider Electric.
  • Reference: A9F79450.
  • EAN: 3606480093463.
  • Range: Acti9.
  • Family: iC60.
  • Model: iC60N.
  • Type: miniature circuit breaker.
  • Application: electrical distribution.
  • Number of poles: 4P.
  • Protected poles: 4.
  • Rated current: 50 A.
  • Curve: C.
  • Tripping: thermal-magnetic.
  • Magnetic threshold: 8 x In ±20 %.
  • Icn: 6 kA according to IEC/EN 60898-1.
  • Icu at 380-415 V: 10 kA according to IEC/EN 60947-2.
  • Icu at 220-240 V: 20 kA according to IEC/EN 60947-2.
  • Limiting class: 3.
  • Utilization category: A.
  • Ui: 500 V.
  • Uimp: 6 kV.
  • Overvoltage category: IV.
  • Suitable for isolation: yes.
  • Mounting: 35 mm DIN rail.
  • 9 mm modules: 8.
  • 18 mm modules: 4.
  • Width: 72 mm.
  • Height: 85 mm.
  • Depth: 78.5 mm.
  • Weight: approximately 0.5 kg.
  • Rigid conductor: 1-35 mm².
  • Flexible conductor: 1-25 mm².
  • Strip length: 14 mm.
  • Tightening torque: 3.5 Nm.
  • Mechanical endurance: 20,000 cycles.
  • Electrical endurance: 10,000 cycles.
  • Protection rating: IP20.
  • Integrated residual current protection: no.
  • Operating temperature: -35 to +70 °C.
  • Storage temperature: -40 to +85 °C.
  • Standards: IEC/EN 60898-1 and IEC/EN 60947-2.

4-pole Acti9 iC60N 50 A circuit breaker

The Schneider Electric A9F79450 combines four protected poles, a 50 A rating, C curve and thermal-magnetic protection in a modular device 72 mm wide. It offers 6 kA breaking capacity according to IEC/EN 60898-1 and 10 kA at 380-415 V according to IEC/EN 60947-2, making it suitable for residential and commercial panels as well as certain industrial applications.

Its suitability for isolation, compatibility with auxiliaries and Vigi blocks, terminals up to 35 mm² and high mechanical and electrical durability make it easy to integrate into professional distribution panels. To select the correct circuit breaker, the conductor cross-section, design current, tripping curve and prospective short-circuit current at the installation point must be verified.

Specifications
Manufacturer
SCHNEIDER ELECTRIC
Reference
A9F79450
SKU
SCH4695982F
Object
Magnetic circuit breaker
Number of poles
Assembly
Fixed
Nominal current
50 A
Network type
CA, CC
Protection rating
IP20
Frequency
50.00 - 60.00 Hz
Datasheets
Reviews
Returns within 30 days
Shop with peace of mind. If something goes wrong, we'll take care of it.
After-sales service
Any questions? Our support team will be happy to help you.
Pay how and when you want
Card, bank transfer, PayPal... Installment? We have them all.
GroupSumi is your online distributor for construction, electrical material and climate control.
All rights reserved © 2026 GroupSumi