IC60N Circuit Breaker 2P 16A Curve D with reference A9F75216 from the brand SCHNEIDER ELECTRIC
IC60N Circuit Breaker 2P 16A Curve D with reference A9F75216 from the brand SCHNEIDER ELECTRIC
SCHNEIDER ELECTRIC

IC60N Circuit Breaker 2P 16A Curve D

REF
A9F75216
(0)
69.50 €
€69.50
€348.25
Up to -6% for professionals. Discover it.
Schneider Electric Acti9 iC60N 2P 16A D curve miniature circuit breaker, 6 kA breaking capacity, VisiTrip and VisiSafe, with thermal-magnetic protection for high inrush currents.
Buy now and receive it between 20 and November 23
Express delivery
Get +70 +139 Sumis for the purchase
Receive 2x Sumis for a limited time
More about the product

Information about IC60N Circuit Breaker 2P 16A Curve D

The Schneider Electric Acti9 iC60N A9F75216 miniature circuit breaker is a bipolar automatic circuit breaker rated at 16 A with D curve, designed to protect electrical circuits against overloads and short circuits. It features 2 protected poles, thermal-magnetic tripping, and a breaking capacity of 6 kA at 400 V AC according to IEC/EN 60898-1, making it especially suitable for circuits with loads that have high inrush currents.

The A9F75216 reference belongs to Schneider Electric's professional Acti9 iC60N range and incorporates VisiTrip and VisiSafe technologies, which make it easy to identify tripping events and verify contact status. It can be used in AC and DC networks and supports the addition of compatible auxiliaries and Vigi residual current blocks.

16 A bipolar miniature circuit breaker with D curve

The Schneider Electric A9F75216 has 2 poles with both poles protected and a rated current of 16 A. Its D curve provides a magnetic threshold of 12 times the rated current, with a tolerance of ±20%.

This feature allows it to withstand high current peaks during the start-up of certain loads, making the D curve suitable for properly sized applications with motors, transformers, and other loads with strong starting currents.

  • Rated current: 16 A.
  • Number of poles: 2P.
  • Protected poles: 2.
  • Tripping curve: D.
  • Trip unit: thermal-magnetic.
  • Magnetic threshold: 12 x In ±20%.
  • Network type: AC and DC.
  • Frequency: 50/60 Hz.

Protection against overloads and short circuits

The Acti9 iC60N combines thermal and magnetic protection in a single device. The thermal element acts against sustained overloads that could cause excessive heating of the conductors, while the magnetic trip enables rapid disconnection when a high short-circuit current occurs.

This combination provides protection for lines and distribution circuits within low-voltage electrical panels.

6 kA breaking capacity according to IEC/EN 60898-1

The A9F75216 offers a rated breaking capacity Icn of 6,000 A at 400 V AC in accordance with IEC/EN 60898-1. According to IEC/EN 60947-2, its breaking capacity varies depending on the operating voltage:

  • 12-133 V AC: Icu of 36 kA.
  • 220-240 V AC: Icu of 20 kA.
  • 380-415 V AC: Icu of 10 kA.
  • 440 V AC: Icu of 6 kA.
  • 72-125 V DC: Icu of 10 kA.

At 380-415 V AC, the service breaking capacity Ics reaches 7.5 kA, equivalent to 75% of Icu according to IEC/EN 60947-2. According to IEC/EN 60898-1, Ics reaches 6 kA at 400 V AC.

D curve for high inrush currents

The D curve sets this model apart from B or C curve versions. Its higher magnetic threshold allows it to tolerate short-duration current surges generated during the start-up of certain loads without causing nuisance tripping.

When selecting a D curve miniature circuit breaker, the available short-circuit current, line impedance, conductor cross-section, and the characteristics of the protected load must be taken into account.

VisiTrip for quick trip identification

The VisiTrip technology includes a front indicator that makes it easy to quickly identify that the circuit breaker has operated due to an electrical fault. This signaling is especially useful in panels with numerous circuits, simplifying diagnosis and maintenance tasks.

VisiSafe and suitability for isolation

The VisiSafe system allows visual verification of the physical opening of the contacts, helping maintenance operations with a clear identification of the switch status.

The A9F75216 is also suitable for isolation according to IEC/EN 60898-1 and IEC/EN 60947-2.

Electrical insulation and impulse withstand

The miniature circuit breaker offers a rated insulation voltage Ui of 500 V AC and a rated impulse withstand voltage Uimp of 6 kV, as well as overvoltage category IV.

  • Insulation voltage Ui: 500 V AC.
  • Impulse withstand voltage Uimp: 6 kV.
  • Overvoltage category: IV.
  • Pollution degree: 3.
  • Utilization category: A.

Compatible with auxiliaries and Vigi residual current protection

The Schneider Electric Acti9 iC60N can be complemented with electrical auxiliaries, remote monitoring devices, and compatible Vigi residual current blocks. This modularity makes it possible to expand signaling, tripping, control, or residual current protection functions according to the needs of the panel.

Residual current protection is not integrated in the A9F75216 reference and must be added with a compatible device when required.

DIN rail mounting

The miniature circuit breaker is designed for fixed mounting on a DIN rail and supports connection via compatible comb busbar from both the top and bottom.

Its bipolar format occupies 4 modules of 9 mm, equivalent to 36 mm in width.

  • Height: 85 mm.
  • Width: 36 mm.
  • Depth: 78.5 mm.
  • Weight: 0.25 kg.
  • Modular width: 4 modules of 9 mm.
  • Color: white.

Conductor connection

The terminals accept wiring from the top or bottom and are prepared for the following cross-sections:

  • Rigid conductor: 1 to 25 mm².
  • Flexible conductor: 1 to 16 mm².
  • Strip length: 14 mm.
  • Tightening torque: 2 Nm.

High durability

The Acti9 iC60N A9F75216 is designed to withstand a high number of operations throughout its service life.

  • Mechanical durability: 20,000 cycles.
  • Electrical durability: 10,000 cycles.

IP20 protection and wide temperature range

The device offers an IP20 protection rating according to IEC/EN 60529 and is designed to be installed inside a suitable electrical enclosure or panel.

  • Protection rating: IP20.
  • Operating temperature: -35 to 70 °C.
  • Storage temperature: -40 to 85 °C.
  • Relative humidity: up to 95% at 55 °C.
  • Maximum operating altitude: 2,000 m.

Schneider Electric A9F75216 technical characteristics

  • Brand: Schneider Electric.
  • Range: Acti9.
  • Series: iC60N.
  • Reference: A9F75216.
  • Type: miniature circuit breaker.
  • Application: electrical distribution.
  • Number of poles: 2P.
  • Protected poles: 2.
  • Rated current: 16 A.
  • Curve: D.
  • Trip: thermal-magnetic.
  • Magnetic threshold: 12 x In ±20%.
  • Network: AC/DC.
  • Frequency: 50/60 Hz.
  • Icn at 400 V AC according to IEC/EN 60898-1: 6 kA.
  • Icu at 380-415 V AC according to IEC/EN 60947-2: 10 kA.
  • Icu at 220-240 V AC: 20 kA.
  • Icu at 440 V AC: 6 kA.
  • Ui: 500 V AC.
  • Uimp: 6 kV.
  • VisiTrip: yes.
  • VisiSafe: yes.
  • Suitable for isolation: yes.
  • Residual current protection: via compatible independent Vigi block.
  • Mounting: DIN rail.
  • Dimensions: 85 x 36 x 78.5 mm.
  • Weight: 0.25 kg.
  • Rigid conductor: 1-25 mm².
  • Flexible conductor: 1-16 mm².
  • Tightening torque: 2 Nm.
  • Mechanical durability: 20,000 cycles.
  • Electrical durability: 10,000 cycles.
  • Protection rating: IP20.
  • Operating temperature: -35 to 70 °C.
  • Standards: IEC/EN 60898-1 and IEC/EN 60947-2.

The Schneider Electric Acti9 iC60N A9F75216 2-pole, 16 A, D curve provides complete protection against overloads and short circuits in circuits with high inrush currents. Its 6 kA breaking capacity according to IEC/EN 60898-1, 10 kA capacity at 380-415 V according to IEC/EN 60947-2, VisiTrip and VisiSafe systems, and compatibility with Acti9 auxiliaries make it suitable for integration into professional electrical panels with demanding protection requirements.

Specifications
Manufacturer
SCHNEIDER ELECTRIC
Reference
A9F75216
SKU
SCHFAB00E25
Object
Magnetic circuit breaker
Number of poles
Assembly
Fixed
Nominal current
16 A
Network type
CA, CC
Protection rating
IP20
Frequency
50.00 - 60.00 Hz
Datasheets
Reviews
Returns within 30 days
Shop with peace of mind. If something goes wrong, we'll take care of it.
After-sales service
Any questions? Our support team will be happy to help you.
Pay how and when you want
Card, bank transfer, PayPal... Installment? We have them all.
GroupSumi is your online distributor for construction, electrical material and climate control.
All rights reserved © 2026 GroupSumi