The Schneider Electric A9F79225 is a thermal-magnetic circuit breaker from the Acti9 iC60N range, designed to protect electrical circuits against overloads and short circuits. It features 2 protected poles, a rated current of 25 A, and C tripping curve, with an Icu breaking capacity of 10 kA at 380-415 V AC according to IEC/EN 60947-2 and an Icn breaking capacity of 6 kA at 400 V according to IEC/EN 60898-1.
Its thermal-magnetic tripping technology combines thermal protection against sustained overloads with fast magnetic action against short circuits. In addition, it incorporates the VisiTrip and VisiSafe functions characteristic of the Acti9 range, making it easier to identify tripped circuits and improving visual verification of contact status during maintenance operations.
The Acti9 iC60N A9F79225 incorporates a thermal-magnetic trip unit. Thermal protection acts against prolonged overcurrents that can cause excessive heating of the conductors, while magnetic protection responds quickly when a high short-circuit current occurs.
This combination helps protect lines and connected equipment against two of the main overcurrent faults present in low-voltage electrical installations.
The A9F79225 reference has 2 poles with thermal-magnetic protection on both. The circuit breaker opening allows both connected conductors to be interrupted simultaneously, making it suitable for circuits where bipolar protection is required.
The rated current of the breaker is 25 A. Correct selection of the circuit breaker must take into account conductor cross-section, load type, installation conditions, and upstream and downstream protection devices.
The Schneider Electric A9F79225 uses a C curve. The manufacturer specifies a magnetic tripping limit of 8 times the rated current with a tolerance of ±20 %.
This curve is suitable for many distribution circuits that may present moderate inrush currents when loads are switched on. Suitability for a specific application should be checked according to the electrical characteristics of the circuit.
The breaking capacity of the iC60N depends on the operating voltage and the standard applied. At 380-415 V AC, the A9F79225 offers an ultimate breaking capacity Icu of 10 kA according to IEC/EN 60947-2.
Voltage Breaking capacity Standard 220-240 V AC 20 kA Icu IEC/EN 60947-2 380-415 V AC 10 kA Icu IEC/EN 60947-2 440 V AC 6 kA Icu IEC/EN 60947-2 400 V AC 6 kA Icn IEC/EN 60898-1Therefore, the commercial designation of 10 kA corresponds to the breaking capacity indicated in accordance with IEC/EN 60947-2 for a voltage of 380-415 V AC.
In addition to the ultimate breaking capacity Icu, Schneider Electric specifies for this circuit breaker a service breaking capacity Ics equivalent to 75% of Icu for several operating voltages.
Voltage Service breaking capacity Ics 220-240 V AC 15 kA 380-415 V AC 7.5 kA 440 V AC 4.5 kA 400 V AC according to IEC/EN 60898-1 6 kAThe VisiTrip technology provides a visual indication when the circuit breaker has tripped due to an electrical fault. This function makes it easier to locate the affected circuit within panels containing multiple protection devices.
This can reduce the time needed to identify which circuit has operated during troubleshooting and maintenance tasks.
The VisiSafe system in the Acti9 range makes it easier to visually verify the physical opening of the contacts. This function is designed to improve safety during intervention and maintenance operations carried out downstream of the breaker.
The A9F79225 is also declared suitable for isolation according to IEC/EN 60898-1 and IEC/EN 60947-2.
The circuit breaker has an energy limiting class 3 according to IEC/EN 60898-1. This capability helps limit the energy passing through the circuit during a short circuit, reducing thermal and electrodynamic stress on downstream conductors and equipment.
The Schneider Electric iC60N A9F79225 is designed for fixed mounting on DIN rail. It has a total width of 36 mm, equivalent to 2 x 18 mm DIN modules, making it easy to integrate with other Acti9 devices in modular electrical panels.
The device can be supplied from the top or bottom and is compatible with comb busbar distribution systems in suitable configurations.
The terminals of the A9F79225 allow rigid or flexible conductors to be connected from the top or bottom.
Conductor type Maximum cross-section Rigid conductor 1 to 25 mm² Flexible conductor 1 to 16 mm² Stripping length 14 mm Tightening torque 2 NmSchneider Electric specifies a mechanical durability of 20,000 cycles and an electrical durability of 10,000 cycles for the A9F79225 under the conditions defined by the manufacturer.
The iC60N can be complemented with different electrical auxiliaries and remote monitoring devices from the Acti9 range to add signaling, tripping, and control functions.
It can also be combined with a compatible Vigi residual current block when protection against earth leakage currents is required. The A9F79225 by itself is a thermal-magnetic circuit breaker and does not include integrated residual current protection.
The Schneider Electric Acti9 iC60N A9F79225 is suitable for protecting bipolar circuits up to 25 A compatible with its tripping curve and breaking capacity.
The Schneider Electric A9F79225 complies with IEC/EN 60898-1 and IEC/EN 60947-2 standards applicable to low-voltage circuit breakers intended for overcurrent protection.
The Schneider Electric A9F79225 Acti9 iC60N combines 2 protected poles, a rated current of 25 A, C curve, and a breaking capacity of 10 kA at 380-415 V according to IEC/EN 60947-2. Its thermal-magnetic protection, VisiTrip and VisiSafe technologies, and compact 2 DIN module format offer a practical solution for protecting electrical circuits against overloads and short circuits.