IC60N Circuit Breaker 3P 25A Curve C 10kA with reference A9F79325 from the brand SCHNEIDER ELECTRIC
IC60N Circuit Breaker 3P 25A Curve C 10kA with reference A9F79325 from the brand SCHNEIDER ELECTRIC
SCHNEIDER ELECTRIC

IC60N Circuit Breaker 3P 25A Curve C 10kA

REF
A9F79325
(0)
54.81 €
€54.81
€255.56
Up to -6% for professionals. Discover it.
Schneider Electric Acti9 iC60N 3P 25A C-curve miniature circuit breaker, 6 kA IEC 60898-1 and 10 kA IEC 60947-2, with VisiTrip and VisiSafe for electrical overloads and short circuits.
Buy now and receive it between 20 and November 23
Express delivery
Get +55 +110 Sumis for the purchase
Receive 2x Sumis for a limited time
More about the product

Information about IC60N Circuit Breaker 3P 25A Curve C 10kA

The Schneider Electric Acti9 iC60N A9F79325 miniature circuit breaker is a three-pole automatic circuit breaker rated at 25 A with C curve, designed to protect electrical circuits against overloads and short circuits. It features 3 poles with all 3 poles protected, thermal-magnetic tripping technology, and is suitable for use in both AC networks and certain DC applications.

Reference A9F79325 offers a rated breaking capacity Icn of 6 kA at 400 V AC according to IEC/EN 60898-1 and an ultimate breaking capacity Icu of 10 kA at 380-415 V AC according to IEC/EN 60947-2. It belongs to Schneider Electric's professional Acti9 iC60N range and is designed for modular DIN rail mounting in residential, commercial, and industrial electrical panels.

Three-pole 25 A C-curve miniature circuit breaker

The Schneider Electric A9F79325 has a 3P configuration, with thermal and magnetic protection on all three poles. Its rated current is 25 A and it uses a C tripping curve, one of the most common in electrical distribution circuits.

The C curve allows moderate inrush currents before magnetic tripping occurs, so it can be used in many circuits with resistive, inductive, or mixed loads, provided the installation is properly designed and sized.

  • Number of poles: 3P.
  • Protected poles: 3.
  • Rated current: 25 A.
  • Tripping curve: C.
  • Tripping technology: thermal-magnetic.
  • Rated voltage: 400 V.
  • Network type: AC and DC.
  • Frequency: 50/60 Hz.

Protection against overloads and short circuits

The Acti9 iC60N integrates two complementary protection mechanisms. Thermal protection acts when an overload persists for a certain period of time and could cause excessive heating of the conductors.

Magnetic protection, on the other hand, provides rapid operation against very high currents caused by a short circuit. This combination protects both electrical lines and connected loads against the main risks associated with overcurrents.

6 kA according to IEC/EN 60898-1 and 10 kA according to IEC/EN 60947-2

The breaking capacity of reference A9F79325 must be interpreted according to the standard under which it is declared. Schneider Electric specifies an Icn of 6,000 A at 400 V AC according to IEC/EN 60898-1 and an Icu of 10 kA at 380-415 V AC according to IEC/EN 60947-2.

According to IEC/EN 60947-2, its breaking capacity depends on the operating voltage:

  • 12-133 V AC: Icu of 36 kA.
  • 220-240 V AC: Icu of 20 kA.
  • 380-415 V AC: Icu of 10 kA.
  • 440 V AC: Icu of 6 kA.
  • Up to 180 V DC: Icu of 10 kA.

Therefore, the commercial designation of 10 kA corresponds to its breaking capacity according to IEC/EN 60947-2 at 380-415 V, while according to IEC/EN 60898-1 the rated value is 6 kA at 400 V AC.

C curve for distribution circuits

The C curve is especially common in distribution installations because it offers a balance between sensitivity to short circuits and tolerance to transient inrush currents.

The miniature circuit breaker should be selected taking into account the design current, conductor cross-section and length, circuit impedance, expected short-circuit current, and the characteristics of the connected loads.

VisiTrip for easier diagnosis

The Acti9 iC60 range incorporates VisiTrip technology, designed to make it easier to identify the breaker that has tripped due to an electrical fault. This indication allows faster location of the affected circuit within panels containing numerous protections.

Quick trip identification helps simplify installation diagnostics and maintenance operations.

VisiSafe and suitability for isolation

VisiSafe technology makes it easier to visually check the open state of the breaker, improving identification of the circuit status during maintenance operations.

The Schneider Electric A9F79325 is also suitable for isolation according to IEC/EN 60898-1 and IEC/EN 60947-2, allowing it to be used to isolate the circuit within the conditions established by the manufacturer.

Electrical insulation and surge withstand

The Acti9 iC60N offers insulation characteristics suitable for professional electrical panels. Its rated insulation voltage Ui is 500 V and it withstands impulse voltages of up to 6 kV.

  • Rated insulation voltage Ui: 500 V.
  • Impulse withstand voltage Uimp: 6 kV.
  • Overvoltage category: IV.
  • Pollution degree: 3.
  • Utilization category: A according to IEC/EN 60947-2.
  • Energy limiting class: 3.

Compatible with auxiliaries and residual current protection

The Schneider Electric Acti9 iC60N can be complemented with compatible auxiliary devices, allowing the signaling, tripping, and monitoring functions of the electrical panel to be expanded.

When the installation requires protection against residual differential currents, it can be combined with a compatible separate residual current block. Reference A9F79325 on its own provides thermal-magnetic protection and does not include residual current protection.

Modular DIN rail mounting

The A9F79325 is designed for fixed DIN rail mounting, making it easy to integrate into modular panels. Its three-pole format occupies 3 modules, equivalent to 54 mm in width.

  • Height: 85 mm.
  • Width: 54 mm.
  • Depth: 78.5 mm.
  • Installation depth: 44.5 mm.
  • Module width: 3 modules.
  • Weight: approximately 0.375 kg.
  • Color: white.

Conductor connection

The breaker terminals allow connection of rigid and flexible conductors with suitable cross-sections for 25 A distribution circuits.

  • Rigid conductor: 1 to 25 mm².
  • Flexible conductor: 1 to 16 mm².
  • Tightening torque: 2 Nm.

The final conductor cross-section must be calculated according to the expected current, installation method, line length, ambient temperature, voltage drop, and applicable regulations.

IP20 protection and wide temperature range

The miniature circuit breaker has an IP20 protection rating and is intended to be installed inside a suitable electrical enclosure or panel.

  • Protection rating: IP20.
  • Operating ambient temperature: -35 to 70 °C.
  • Overvoltage category: IV.
  • Pollution degree: 3.

Power loss

The power loss indicated for the Schneider Electric A9F79325 is approximately 3 W. This data may be relevant when calculating the total thermal dissipation of electrical panels with a large number of installed devices.

Compliant with IEC/EN 60898-1 and IEC/EN 60947-2

The Acti9 iC60N miniature circuit breaker is developed in accordance with IEC/EN 60898-1 and IEC/EN 60947-2. These standards define, among other aspects, operating characteristics, breaking capacities, behavior under overcurrents, and insulation requirements for the automatic circuit breaker.

Schneider Electric A9F79325 technical characteristics

  • Brand: Schneider Electric.
  • Range: Acti9.
  • Series: Acti9 iC60.
  • Model: iC60N.
  • Reference: A9F79325.
  • Type: miniature circuit breaker.
  • Application: electrical distribution.
  • Number of poles: 3P.
  • Protected poles: 3.
  • Rated current: 25 A.
  • Curve: C.
  • Tripping unit: thermal-magnetic.
  • Network type: AC/DC.
  • Rated voltage: 400 V.
  • Frequency: 50/60 Hz.
  • Icn at 400 V AC according to IEC/EN 60898-1: 6 kA.
  • Icu at 380-415 V AC according to IEC/EN 60947-2: 10 kA.
  • Icu at 220-240 V AC: 20 kA.
  • Icu at 440 V AC: 6 kA.
  • Icu up to 180 V DC: 10 kA.
  • Energy limiting class: 3.
  • Insulation voltage Ui: 500 V.
  • Impulse withstand voltage Uimp: 6 kV.
  • Overvoltage category: IV.
  • Suitable for isolation: yes.
  • Contact position indicator: yes.
  • Trip indicator: yes.
  • VisiTrip: yes.
  • VisiSafe: yes.
  • Additional auxiliary devices: compatible.
  • Residual current protection: via compatible separate block.
  • Mounting: fixed on DIN rail.
  • Module width: 3 modules.
  • Dimensions: 85 x 54 x 78.5 mm.
  • Weight: approximately 0.375 kg.
  • Rigid conductor: 1-25 mm².
  • Flexible conductor: 1-16 mm².
  • Tightening torque: 2 Nm.
  • Power loss: 3 W.
  • Protection rating: IP20.
  • Operating temperature: -35 to 70 °C.
  • Standards: IEC/EN 60898-1 and IEC/EN 60947-2.

The Schneider Electric Acti9 iC60N A9F79325 3-pole, 25 A, C-curve miniature circuit breaker offers a professional solution for protecting electrical circuits against overloads and short circuits. Its 6 kA breaking capacity according to IEC/EN 60898-1 and 10 kA at 380-415 V according to IEC/EN 60947-2, together with its modular format, VisiTrip and VisiSafe technologies, and the possibility of adding auxiliaries and residual current protection, make it suitable for electrical panels with high safety and protection requirements.

Specifications
Manufacturer
SCHNEIDER ELECTRIC
Reference
A9F79325
SKU
SCH161CD1AF
Object
Magnetic circuit breaker
Number of poles
Assembly
Fixed
Nominal current
25 A
Network type
CA, CC
Protection rating
IP20
Frequency
50.00 - 60.00 Hz
Datasheets
Reviews
Returns within 30 days
Shop with peace of mind. If something goes wrong, we'll take care of it.
After-sales service
Any questions? Our support team will be happy to help you.
Pay how and when you want
Card, bank transfer, PayPal... Installment? We have them all.
GroupSumi is your online distributor for construction, electrical material and climate control.
All rights reserved © 2026 GroupSumi