IC60N Circuit Breaker 3P 32A Curve D with reference A9F75332 from the brand SCHNEIDER ELECTRIC
IC60N Circuit Breaker 3P 32A Curve D with reference A9F75332 from the brand SCHNEIDER ELECTRIC
SCHNEIDER ELECTRIC

IC60N Circuit Breaker 3P 32A Curve D

REF
A9F75332
(0)
128.00 €
€128.00
€593.25
Up to -6% for professionals. Discover it.
Schneider Electric Acti9 iC60N 3P 32 A circuit breaker, D curve and 6 kA breaking capacity. Protects circuits with high inrush currents against overloads and short circuits.
Buy now and receive it between 10 and December 14
Get +128 +256 Sumis for the purchase
Receive 2x Sumis for a limited time
More about the product

Information about IC60N Circuit Breaker 3P 32A Curve D

The Schneider Electric Acti9 iC60N A9F75332 miniature circuit breaker is a modular 3-pole protected, 32 A, D-curve automatic circuit breaker designed to protect electrical circuits against overloads and short circuits. Its thermal-magnetic trip unit combines thermal protection against prolonged overcurrents with fast magnetic tripping in the event of short-circuit currents.

Thanks to its D curve, this miniature circuit breaker is especially suitable for circuits that may experience high inrush currents. Its breaking capacity reaches 6000 A at 400 V AC according to IEC/EN 60898-1 and 10 kA at 380-415 V AC according to IEC/EN 60947-2, offering a robust solution for distribution electrical panels.

Three-phase 32 A miniature circuit breaker with D curve

The A9F75332 reference features a 3P configuration, with all three poles protected, and a rated current of 32 A. The D curve has a magnetic threshold of 12 times the rated current ±20 %, allowing it to withstand high current peaks before instantaneous tripping occurs.

This feature makes the D curve suitable for applications with significant inrush currents, such as certain motors, transformers, reactors, ballasts and other loads with strong starting surges, provided the installation design and conditions are compatible.

Protection against overloads and short circuits

The Acti9 iC60N incorporates a thermal-magnetic trip unit. The thermal part provides protection against sustained overloads, while the magnetic action allows the circuit to be disconnected quickly in the event of a short circuit.

Schneider Electric specifies the following breaking capacities for this model:

  • 6 kA Icn at 400 V AC according to IEC/EN 60898-1.
  • 20 kA Icu at 220-240 V AC according to IEC/EN 60947-2.
  • 10 kA Icu at 380-415 V AC according to IEC/EN 60947-2.
  • 6 kA Icu at 440 V AC according to IEC/EN 60947-2.
  • 10 kA Icu up to 180 V DC according to IEC/EN 60947-2.

The device belongs to utilization category A according to IEC/EN 60947-2 and is suitable for isolation according to IEC/EN 60898-1 and IEC/EN 60947-2 standards.

VisiTrip and VisiSafe technologies

As part of the Acti9 range, the A9F75332 incorporates solutions designed to improve diagnostics and safety during maintenance tasks.

  • VisiTrip: provides a visual indication when the miniature circuit breaker has tripped due to an anomaly, making it easier to quickly locate the affected circuit.
  • VisiSafe: the green strip confirms the physical opening of the contacts, providing a visible indication of the circuit’s open state before downstream interventions are carried out.

These functions help reduce diagnostic times and make installation and maintenance work easier in professional electrical panels.

Energy limiting class 3

The circuit breaker features an energy limiting class 3 according to IEC/EN 60898-1. This characteristic helps limit the energy flowing through the circuit under certain short-circuit conditions, contributing to reducing thermal and electrodynamic stress on downstream conductors and equipment.

Modular DIN rail mounting

The Schneider Electric A9F75332 is designed for fixed installation on DIN rail, making it easy to integrate into distribution boards and modular enclosures. It occupies 6 modules of 9 mm, equivalent to three standard 18 mm modules.

  • Height: 85 mm.
  • Width: 54 mm.
  • Depth: 78.5 mm.
  • Approximate weight: 0.375 kg.
  • Color: white.

The device supports busbar supply from both the top and the bottom, offering flexibility in panel configuration.

Electrical connections

The terminals allow the connection of conductors of different cross-sections to suit typical distribution board wiring:

  • Rigid conductors: from 1 to 35 mm².
  • Flexible conductors: from 1 to 25 mm².
  • Strip length: 14 mm.
  • Tightening torque: 3.5 Nm.

Compatible with auxiliaries and Vigi residual current protection

The modular architecture of the Acti9 range allows the iC60N to be expanded with electrical auxiliaries, signaling and remote monitoring devices, and compatible Vigi residual current blocks.

This means the miniature circuit breaker can be integrated into more complete protection systems when the installation requires additional control, signaling or residual current protection functions.

Technical features of the Schneider Electric A9F75332

  • Brand: Schneider Electric.
  • Reference: A9F75332.
  • Range: Acti9.
  • Model: iC60N.
  • Type: modular miniature circuit breaker.
  • Application: electrical distribution.
  • Number of poles: 3P.
  • Protected poles: 3.
  • Rated current: 32 A.
  • Tripping curve: D.
  • Trip technology: thermal-magnetic.
  • Magnetic threshold: 12 x In ±20 %.
  • Network type: AC / DC.
  • Frequency: 50/60 Hz.
  • IEC/EN 60898-1 breaking capacity: 6000 A at 400 V AC.
  • IEC/EN 60947-2 breaking capacity: 10 kA at 380-415 V AC.
  • Rated insulation voltage Ui: 500 V AC.
  • Rated impulse withstand voltage Uimp: 6 kV.
  • Limiting class: 3.
  • Utilization category: A.
  • Suitable for isolation: yes.
  • Trip indicator: VisiTrip.
  • Safe open indication: VisiSafe.
  • Mounting: fixed on DIN rail.
  • Width: 54 mm.
  • Height: 85 mm.
  • Depth: 78.5 mm.
  • Protection rating: IP20 at terminals.
  • Maximum rigid conductor cross-section: 35 mm².
  • Maximum flexible conductor cross-section: 25 mm².
  • Mechanical durability: 20,000 cycles.
  • Electrical durability: 10,000 cycles.
  • Operating temperature: -35 to 70 °C.
  • Maximum operating altitude: 2000 m.
  • Standards: IEC/EN 60898-1 and IEC/EN 60947-2.
  • EAN: 3606480081040.

Applications of the Acti9 iC60N 3P 32 A D curve

The Schneider Electric A9F75332 miniature circuit breaker is intended for the protection of three-phase circuits in residential, commercial and professional electrical installations. The D curve makes it a particularly interesting option when loads generate higher-than-usual inrush currents and a more tolerant tripping curve is required to handle these peaks.

Its combination of 3 poles, 32 A, D curve, 6 kA breaking capacity, VisiTrip and VisiSafe technologies, and compatibility with Acti9 auxiliaries provides a complete solution for circuit protection and isolation in modular electrical panels.

Specifications
Manufacturer
SCHNEIDER ELECTRIC
Reference
A9F75332
SKU
SCHB58BD9C3
Object
Magnetic circuit breaker
Number of poles
Assembly
Fixed
Nominal current
32 A
Network type
CA, CC
Protection rating
IP20
Frequency
50.00 - 60.00 Hz
Datasheets
Reviews
Returns within 30 days
Shop with peace of mind. If something goes wrong, we'll take care of it.
After-sales service
Any questions? Our support team will be happy to help you.
Pay how and when you want
Card, bank transfer, PayPal... Installment? We have them all.
GroupSumi is your online distributor for construction, electrical material and climate control.
All rights reserved © 2026 GroupSumi