IC60N Circuit Breaker 3P 40A Curve C with reference A9F79340 from the brand SCHNEIDER ELECTRIC
IC60N Circuit Breaker 3P 40A Curve C with reference A9F79340 from the brand SCHNEIDER ELECTRIC
SCHNEIDER ELECTRIC

IC60N Circuit Breaker 3P 40A Curve C

REF
A9F79340
(0)
69.90 €
€69.90
€325.38
Up to -6% for professionals. Discover it.
Schneider Electric Acti9 iC60N 3P 40 A circuit breaker, C curve and 6 kA breaking capacity. Protects three-phase circuits against overloads and short circuits.
Buy now and receive it between 20 and November 23
Express delivery
Get +70 +140 Sumis for the purchase
Receive 2x Sumis for a limited time
More about the product

Information about IC60N Circuit Breaker 3P 40A Curve C

The Schneider Electric Acti9 iC60N A9F79340 miniature circuit breaker is a modular circuit breaker designed to protect electrical circuits against overloads and short circuits. It features 3 protected poles, a rated current of 40 A, and C tripping curve, providing a robust solution for three-phase circuits in residential, commercial, and professional electrical panels.

This circuit breaker uses thermal-magnetic tripping technology and offers a rated breaking capacity of 6000 A at 400 V AC according to IEC/EN 60898-1. In accordance with IEC/EN 60947-2, its Icu breaking capacity reaches 10 kA at 380-415 V AC, making it suitable for installations with higher protection requirements.

40 A three-phase miniature circuit breaker

The A9F79340 reference has a 3P configuration, with thermal and magnetic protection on all three poles. When an overload or short circuit occurs, the mechanism simultaneously opens the three phases to isolate the affected circuit.

  • Number of poles: 3P.
  • Protected poles: 3.
  • Rated current: 40 A.
  • Tripping curve: C.
  • Technology: thermal-magnetic.
  • Application: electrical distribution.

C curve for general-purpose circuits

The C curve is widely used in distribution circuits supplying loads with moderate inrush currents. It can withstand certain transient peaks during load startup without compromising fast tripping in the event of high short-circuit currents.

Thanks to its characteristics, this miniature circuit breaker is suitable for many electrical distribution applications in buildings, shops, offices, tertiary installations, and other properly sized three-phase electrical panels.

Protection against overloads and short circuits

The Acti9 iC60N combines two protection principles in a single device:

  • Thermal protection: operates when a current above the rated value persists for an extended period, preventing overheating of conductors and equipment.
  • Magnetic protection: provides rapid disconnection in the event of high currents caused by a short circuit.

This combination helps protect downstream conductors and loads against the main overcurrent situations.

6 kA breaking capacity according to IEC/EN 60898-1

Schneider Electric specifies a rated breaking capacity Icn of 6000 A at 400 V AC for the A9F79340 in accordance with IEC/EN 60898-1.

When classified according to IEC/EN 60947-2, the breaking capacity depends on the network voltage:

  • 36 kA Icu between 12 and 133 V AC.
  • 20 kA Icu between 220 and 240 V AC.
  • 10 kA Icu between 380 and 415 V AC.
  • 6 kA Icu at 440 V AC.
  • 10 kA Icu between 125 and 180 V DC.

Therefore, for a typical 400 V three-phase network, this reference offers 6 kA according to IEC/EN 60898-1 and 10 kA according to IEC/EN 60947-2.

VisiTrip for easier fault diagnosis

As part of the Acti9 iC60 range, the device incorporates VisiTrip technology, which provides a front mechanical indication when the breaker has tripped due to an electrical fault.

This signaling makes it easier to identify the affected circuit within panels with multiple protective devices and helps reduce diagnosis and maintenance times.

VisiSafe and suitability for isolation

The VisiSafe technology allows visual verification of the physical opening of the contacts through a green indicator. Schneider Electric also specifies that the A9F79340 is suitable for isolation according to IEC/EN 60898-1 and IEC/EN 60947-2.

These features provide an additional safety reference before carrying out work on the downstream circuit.

Energy limiting class 3

The Acti9 iC60N has energy limiting class 3. This feature helps reduce the energy passing through the circuit during a short circuit, lowering the thermal and electrodynamic stress on the protected conductors and equipment.

Compatible with AC and DC networks

The Schneider Electric A9F79340 can be used in alternating current as well as certain direct current applications, always within the electrical values specified by the manufacturer.

  • Network type: AC / DC.
  • AC frequency: 50/60 Hz.
  • Typical rated voltage: 400 V AC.
  • DC breaking capacity: 10 kA between 125 and 180 V DC according to IEC/EN 60947-2.

Modular DIN rail mounting

The miniature circuit breaker is designed for fixed installation on DIN rail. It occupies three standard 18 mm modules, making it easy to integrate alongside residual current devices, contactors, surge protection devices, and other modular Acti9 devices.

  • Height: 85 mm.
  • Width: 54 mm.
  • Depth: 78.5 mm.
  • Installation depth: 44.5 mm.
  • Modular width: 3 modules.
  • Weight: approximately 0.375 kg.
  • Color: white.

Connection of conductors up to 35 mm²

The A9F79340 has terminals designed for copper conductors of different cross-sections, adapting to the usual wiring of three-phase distribution circuits.

  • Rigid conductor: 1 to 35 mm².
  • Flexible conductor: 1 to 25 mm².
  • Strip length: 14 mm.
  • Tightening torque: 3.5 Nm.

Power supply can be connected from the top or bottom of the miniature circuit breaker, offering flexibility during panel assembly and wiring.

Compatible with auxiliaries and residual current protection

The modular Acti9 architecture allows the iC60N to be complemented with signaling auxiliaries, remote tripping devices, and compatible residual current blocks. This makes it possible to create more complete protection solutions without changing the switchgear platform.

The device does not include integrated residual current protection. When the installation requires protection against residual currents, it must be combined with a compatible residual current block or the corresponding residual current device must be installed.

IP20 protection and high durability

The breaker has an IP20 protection rating according to IEC 60529 and is designed to be installed inside a suitable enclosure or panel.

The Acti9 iC60 range is designed to offer high mechanical and electrical durability in professional applications, maintaining performance across a wide temperature range.

  • Operating temperature: -35 to 70 °C.
  • Pollution degree: 3.
  • Overvoltage category: IV.
  • Rated insulation voltage Ui: 500 V.
  • Impulse withstand voltage Uimp: 6 kV.
  • Power loss: approximately 3.6 W.

Technical characteristics of the Schneider Electric A9F79340

  • Brand: Schneider Electric.
  • Reference: A9F79340.
  • Range: Acti9.
  • Product: Acti9 iC60N.
  • Type: modular miniature circuit breaker.
  • Application: electrical distribution.
  • Number of poles: 3P.
  • Protected poles: 3.
  • Rated current: 40 A.
  • Tripping curve: C.
  • Tripping technology: thermal-magnetic.
  • Network type: AC and DC.
  • Frequency: 50/60 Hz.
  • Rated voltage: 400 V AC.
  • Breaking capacity Icn: 6 kA at 400 V AC according to IEC/EN 60898-1.
  • Breaking capacity Icu: 20 kA at 220-240 V AC according to IEC/EN 60947-2.
  • Breaking capacity Icu: 10 kA at 380-415 V AC according to IEC/EN 60947-2.
  • Breaking capacity Icu: 6 kA at 440 V AC according to IEC/EN 60947-2.
  • DC breaking capacity: 10 kA between 125 and 180 V DC.
  • Utilization category: A.
  • Limiting class: 3.
  • Insulation voltage Ui: 500 V.
  • Impulse withstand voltage Uimp: 6 kV.
  • Suitable for isolation: yes.
  • Trip indicator: VisiTrip.
  • Open position indication: VisiSafe.
  • Mounting: fixed on DIN rail.
  • Height: 85 mm.
  • Width: 54 mm.
  • Depth: 78.5 mm.
  • Installation depth: 44.5 mm.
  • Weight: approximately 0.375 kg.
  • Rigid conductor: 1-35 mm².
  • Flexible conductor: 1-25 mm².
  • Tightening torque: 3.5 Nm.
  • Protection rating: IP20.
  • Operating temperature: -35 to 70 °C.
  • Pollution degree: 3.
  • Overvoltage category: IV.
  • Power loss: approximately 3.6 W.
  • Standards: IEC/EN 60898-1 and IEC/EN 60947-2.
  • EAN: 3606480093364.

Three-phase protection for electrical panels

The Schneider Electric A9F79340 provides a complete solution for protecting 40 A three-phase lines against overloads and short circuits. Its C curve makes it suitable for many distribution circuits with general-purpose loads and moderate inrush currents.

The combination of 3 protected poles, 40 A, C curve, 6 kA according to IEC/EN 60898-1, 10 kA at 380-415 V according to IEC/EN 60947-2, VisiTrip, and VisiSafe makes it an especially suitable choice for residential, commercial, tertiary, and professional electrical panels.

Specifications
Manufacturer
SCHNEIDER ELECTRIC
Reference
A9F79340
SKU
SCH86BAA956
Object
Magnetic circuit breaker
Number of poles
Assembly
Fixed
Nominal current
40 A
Network type
CA, CC
Protection rating
IP20
Frequency
50.00 - 60.00 Hz
Datasheets
Reviews
Returns within 30 days
Shop with peace of mind. If something goes wrong, we'll take care of it.
After-sales service
Any questions? Our support team will be happy to help you.
Pay how and when you want
Card, bank transfer, PayPal... Installment? We have them all.
GroupSumi is your online distributor for construction, electrical material and climate control.
All rights reserved © 2026 GroupSumi