IC60N Circuit Breaker 4P 16A Curve B with reference A9F78416 from the brand SCHNEIDER ELECTRIC
IC60N Circuit Breaker 4P 16A Curve B with reference A9F78416 from the brand SCHNEIDER ELECTRIC
SCHNEIDER ELECTRIC

IC60N Circuit Breaker 4P 16A Curve B

REF
A9F78416
(0)
98.89 €
€98.89
€426.57
Up to -6% for professionals. Discover it.
Schneider Electric Acti9 iC60N 4P 16 A B curve miniature circuit breaker, 10 kA according to IEC 60947-2, with VisiTrip, VisiSafe, thermal-magnetic protection and DIN rail mounting.
Buy now and receive it between 20 and November 23
Express delivery
Get +99 +198 Sumis for the purchase
Receive 2x Sumis for a limited time
More about the product

Information about IC60N Circuit Breaker 4P 16A Curve B

The Schneider Electric A9F78416 is a thermal-magnetic circuit breaker from the Acti9 iC60N range, designed to protect electrical circuits against overloads and short circuits. It features 4 protected poles, a rated current of 16 A, and B tripping curve, with an Icu breaking capacity of 10 kA at 380-415 V AC according to IEC/EN 60947-2 and an Icn breaking capacity of 6 kA at 400 V AC according to IEC/EN 60898-1.

Its thermal-magnetic tripping technology combines thermal protection against prolonged overloads with fast magnetic operation in the event of short circuits. It also incorporates Schneider Electric’s VisiTrip and VisiSafe technologies, which respectively make it easier to identify tripped circuits and visually verify the safe opening of the contacts.

Key features of the Schneider Electric A9F78416

  • Modular thermal-magnetic circuit breaker.
  • Brand: Schneider Electric.
  • Range: Acti9 iC60.
  • Model: iC60N.
  • Reference: A9F78416.
  • Number of poles: 4P.
  • Number of protected poles: 4.
  • Rated current: 16 A.
  • Tripping curve: B.
  • Tripping technology: thermal-magnetic.
  • Icu breaking capacity: 10 kA at 380-415 V AC according to IEC/EN 60947-2.
  • Icn breaking capacity: 6 kA at 400 V AC according to IEC/EN 60898-1.
  • Icu breaking capacity of 20 kA at 220-240 V AC according to IEC/EN 60947-2.
  • Icu breaking capacity of 6 kA at 440 V AC according to IEC/EN 60947-2.
  • Network frequency: 50/60 Hz.
  • Magnetic tripping threshold: 4 x In ±20 %.
  • Rated insulation voltage Ui: 500 V.
  • Rated impulse withstand voltage Uimp: 6 kV.
  • Energy limiting class: 3.
  • Suitable for isolation.
  • VisiTrip trip indicator.
  • VisiSafe safety system.
  • DIN rail mounting.
  • Width: 72 mm, equivalent to 4 DIN modules.
  • Terminal protection rating: IP20.

4-pole thermal-magnetic protection

The A9F78416 incorporates thermal-magnetic protection on all four poles, allowing the four conductors connected to the device to be protected and disconnected simultaneously. This configuration is especially suitable for distribution circuits where four-pole protection is required.

The thermal part of the mechanism responds to sustained overloads that can cause excessive heating of the conductors, while the magnetic trip unit acts quickly against high short-circuit currents.

B tripping curve

This model uses a B curve, with a magnetic operating threshold specified by Schneider Electric of 4 times the rated current with a tolerance of ±20 %.

The B curve has a more sensitive magnetic response than a C curve and is especially suited to circuits with low or moderate inrush currents. It can be used, for example, in certain distribution circuits, lighting circuits, and resistive loads, provided the curve is suitable for the actual electrical characteristics of the installation.

Breaking capacity

The breaking capacity of the Acti9 iC60N depends on the operating voltage and the applicable standard. At a voltage of 380-415 V AC, the A9F78416 provides an ultimate breaking capacity Icu of 10 kA in accordance with IEC/EN 60947-2.

Voltage Breaking capacity Standard 220-240 V AC 20 kA Icu IEC/EN 60947-2 380-415 V AC 10 kA Icu IEC/EN 60947-2 440 V AC 6 kA Icu IEC/EN 60947-2 400 V AC 6 kA Icn IEC/EN 60898-1

Therefore, to correctly identify this circuit breaker, it is important to distinguish between the 10 kA according to IEC/EN 60947-2 and the 6 kA according to IEC/EN 60898-1.

VisiTrip for quickly locating a trip

The VisiTrip technology provides a front indication that makes it easy to identify when the circuit breaker has tripped due to an electrical fault. This function is especially useful in panels with numerous circuits, as it helps quickly locate the protection device that has operated.

This makes fault diagnosis easier and reduces the time needed to identify the affected circuit.

VisiSafe for checking isolation

The VisiSafe system provides a visual indication that allows you to verify that the contacts are physically open. The circuit breaker is also declared suitable for isolation in accordance with IEC/EN 60898-1 and IEC/EN 60947-2.

This feature is especially useful during inspection and maintenance work on the electrical installation.

Energy limiting class 3

The Schneider Electric A9F78416 has energy limiting class 3. This feature helps reduce the energy passing through the installation during a short circuit, lowering the thermal and electrodynamic stresses on downstream conductors and equipment.

Electrical characteristics

Characteristic Value Rated current In 16 A Number of poles 4P Protected poles 4 Tripping curve B Technology Thermal-magnetic Rated voltage 400 V Frequency 50/60 Hz Magnetic tripping threshold 4 x In ±20 % Icn at 400 V according to IEC/EN 60898-1 6 kA Icu at 380-415 V according to IEC/EN 60947-2 10 kA Rated insulation voltage Ui 500 V Rated impulse withstand voltage Uimp 6 kV Utilization category A Energy limiting class 3

Modular DIN rail mounting

The Acti9 iC60N A9F78416 is designed for fixed installation on a DIN rail. Its four poles occupy a total width of 72 mm, equivalent to 4 DIN modules of 18 mm.

This format makes it easy to integrate with other Schneider Electric modular devices, such as residual current devices, contactors, control auxiliaries, and signaling elements within distribution switchboards.

Conductor connection

As it is rated at 25 A or less, the iC60N accepts rigid copper conductors up to 25 mm² and flexible conductors up to 16 mm².

Conductor type Permitted cross-section Rigid conductor 1 to 25 mm² Flexible conductor 1 to 16 mm² Tightening torque 2 Nm

Dimensions

Characteristic Value Height 85 mm Width 72 mm Depth 78.5 mm Installation depth 44.5 mm Modular width 4 DIN modules Protection rating IP20

Wide temperature range

The Schneider Electric A9F78416 is designed to operate at ambient temperatures between -35 and +70 °C, allowing it to be used in a wide variety of electrical panels and installations.

The device also has pollution degree 3 and overvoltage category IV according to its technical characteristics.

Compatibility with Acti9 auxiliaries

The iC60N allows different electrical auxiliaries and Acti9 accessories to be added to expand its functions. Schneider Electric options include signaling devices, remote trip units, and monitoring accessories.

It can also be combined with a compatible Vigi residual current protection unit when residual current detection is required. The A9F78416 on its own is a circuit breaker and does not include integrated residual current protection.

Recommended applications

The Schneider Electric Acti9 iC60N A9F78416 is suitable for four-pole circuits up to 16 A where a B tripping curve and protection against overloads and short circuits are required.

  • Main and secondary distribution boards.
  • Residential installations.
  • Commercial premises.
  • Tertiary buildings.
  • Three-phase circuits with four conductors to be protected.
  • Lighting circuits compatible with B curve.
  • Resistive loads and circuits with low inrush currents.
  • Professional low-voltage electrical installations.

Standards

The Schneider Electric A9F78416 thermal-magnetic circuit breaker complies with IEC/EN 60898-1 and IEC/EN 60947-2 standards applicable to low-voltage circuit breakers intended to protect circuits against overcurrents.

Technical summary of the Schneider Electric A9F78416

Characteristic Specification Brand Schneider Electric Range Acti9 iC60N Reference A9F78416 Type Thermal-magnetic circuit breaker Poles 4P Protected poles 4 Rated current 16 A Curve B Icn at 400 V according to IEC/EN 60898-1 6 kA Icu at 380-415 V according to IEC/EN 60947-2 10 kA Magnetic threshold 4 x In ±20 % Ui 500 V Uimp 6 kV Limiting class 3 VisiTrip Yes VisiSafe Yes Mounting DIN rail Dimensions 85 x 72 x 78.5 mm Protection rating IP20 EAN 3606480092961

The Schneider Electric A9F78416 Acti9 iC60N combines four protected poles, 16 A, B curve, thermal-magnetic protection, and a 10 kA breaking capacity according to IEC/EN 60947-2. Its VisiTrip and VisiSafe technologies, modular format, and compatibility with Acti9 auxiliaries provide a complete solution for low-voltage electrical circuit protection.

Specifications
Manufacturer
SCHNEIDER ELECTRIC
Reference
A9F78416
SKU
SCH282BBEF4
Object
Magnetic circuit breaker
Number of poles
Assembly
Fixed
Nominal current
16 A
Network type
CA, CC
Protection rating
IP20
Frequency
50.00 - 60.00 Hz
Datasheets
Reviews
Returns within 30 days
Shop with peace of mind. If something goes wrong, we'll take care of it.
After-sales service
Any questions? Our support team will be happy to help you.
Pay how and when you want
Card, bank transfer, PayPal... Installment? We have them all.
GroupSumi is your online distributor for construction, electrical material and climate control.
All rights reserved © 2026 GroupSumi