

The Schneider Electric Acti9 iC60N A9F75420 miniature circuit breaker is a modular 4-pole, 20 A, D-curve automatic circuit breaker designed to protect electrical circuits against overloads and short circuits. It incorporates thermal-magnetic protection on all four poles and offers a rated breaking capacity Icn of 6 kA at 400 V AC according to IEC/EN 60898-1, as well as an ultimate breaking capacity Icu of 10 kA at 380-415 V AC in accordance with IEC/EN 60947-2.
It belongs to Schneider Electric's Acti9 iC60 range and is especially suitable for distribution boards where loads may have high inrush currents. Its D curve has a magnetic trip threshold of approximately 12 times the rated current, with a tolerance of ±20%, allowing it to withstand transient surges higher than those of a C-curve miniature circuit breaker.
The A9F75420 has four protected poles. Each pole includes overcurrent protection and the mechanism performs simultaneous opening of the circuit when a trip or manual operation occurs.
This configuration is especially useful in installations where simultaneous disconnection of four conductors is required, together with thermal-magnetic protection on all of them.
The iC60N combines two protection technologies. The thermal element responds to prolonged overloads that could cause excessive heating of the conductors, while the magnetic system acts quickly against high short-circuit currents.
In this way, the circuit breaker protects the wiring and connected equipment within the limits defined by Schneider Electric and by the design of the installation.
The A9F75420 reference uses a D tripping curve. Schneider Electric sets a magnetic threshold of 12 times the rated current with a tolerance of ±20%.
This behavior allows high connection currents to be tolerated for brief moments without nuisance tripping, so the D curve may be suitable for loads such as certain motors, transformers, machinery, or equipment with high starting currents.
Selecting a D curve requires checking that the available short-circuit current is sufficient to ensure tripping within the times established by the standard.
The Acti9 iC60N A9F75420 has a rated breaking capacity Icn of 6000 A at 400 V AC in accordance with IEC/EN 60898-1.
The service breaking capacity Ics under these conditions is also 6 kA, equivalent to 100% of Icn.
When evaluated according to IEC/EN 60947-2, Schneider Electric specifies different ultimate breaking capacity Icu values:
The breaking capacity of the circuit breaker must be equal to or greater than the prospective short-circuit current at the exact installation point.
The Acti9 iC60 range includes the VisiTrip function, which provides a red visual indication when the device has tripped due to an electrical fault.
This indication makes it easier to quickly locate the affected circuit within boards with numerous breakers and simplifies diagnosis and maintenance tasks.
The VisiSafe system provides a green indication when the contacts are in a position that allows the circuit to be considered disconnected according to the conditions established by Schneider Electric.
The A9F75420 is also declared suitable for isolation in accordance with IEC/EN 60898-1 and IEC/EN 60947-2.
Schneider Electric equips the Acti9 iC60 range with a Fast Closing mechanism, which limits the influence of the speed at which the user operates the lever on contact closing.
This technology helps reduce electrical wear associated with switching and promotes greater device durability.
The circuit breaker has a rated insulation voltage Ui of 500 V AC and an impulse withstand voltage Uimp of 6 kV.
The technical documentation also classifies it with overvoltage category IV and pollution degree 3.
The A9F75420 is designed for fixed clip-on mounting on a DIN rail. It occupies 8 x 9 mm modules, equivalent to four standard 18 mm modules.
Schneider Electric specifies compatibility with distribution blocks and comb busbars from both the top and bottom. This makes it easier to build modular panels with an orderly electrical distribution and reduces individual wiring between devices.
The terminals allow connection from the top or bottom of the device. The manufacturer’s specified capacity is:
The final cross-section must be selected according to the design current, installation method, voltage drop, temperature, and applicable regulations.
The Schneider Electric iC60N is designed to withstand a high number of operations:
These features make it suitable for distribution boards where a long service life is required.
The circuit breaker has an IP20 protection rating according to IEC/EN 60529. It must be installed inside an enclosure or electrical panel that provides adequate protection for the environmental conditions of the site.
Schneider Electric specifies broad environmental conditions:
The A9F75420 provides protection against overloads and short circuits, but does not include residual current protection as standard.
When the installation requires protection against earth leakage, it can be combined with a compatible residual current solution from the Acti9 range selected according to the number of poles, current rating, sensitivity, and required residual current class.
Thanks to its four-pole configuration, D curve, and 20 A rating, this circuit breaker can be used in:
The Schneider Electric A9F75420 combines four protected poles, a 20 A rating, and a D curve with a breaking capacity of 6 kA according to IEC/EN 60898-1 and 10 kA Icu at 380-415 V according to IEC/EN 60947-2. Its tripping curve makes it especially suitable for circuits that experience high current surges during connection.
The VisiTrip and VisiSafe functions make it easier to identify trips and verify circuit status, while compatibility with comb busbars, DIN rail mounting, and high durability simplify integration into professional distribution boards.
Selecting a D curve should be done by checking the load starting current, conductor cross-section, available short-circuit current, and the actual installation conditions.