IK60N Circuit Breaker 2P 63A Curve C with reference A9K24263 from the brand SCHNEIDER ELECTRIC
IK60N Circuit Breaker 2P 63A Curve C with reference A9K24263 from the brand SCHNEIDER ELECTRIC
SCHNEIDER ELECTRIC

IK60N Circuit Breaker 2P 63A Curve C

REF
A9K24263
(0)
89.00 €
€89.00
€349.44
Up to -6% for professionals. Discover it.
Schneider Electric Acti9 iK60N 2P 63A C-curve miniature circuit breaker, 6 kA breaking capacity, thermal-magnetic protection and DIN rail mounting for residential and commercial electrical panels.
Buy now and receive it between 20 and November 23
Express delivery
Get +89 +178 Sumis for the purchase
Receive 2x Sumis for a limited time
More about the product

Information about IK60N Circuit Breaker 2P 63A Curve C

The Schneider Electric Acti9 iK60N A9K24263 thermal-magnetic circuit breaker is a bipolar automatic switch rated at 63 A with C curve, designed to protect electrical circuits against overloads and short circuits. It features 2 protected poles, thermal-magnetic tripping technology, and a rated breaking capacity of 6 kA in accordance with EN/IEC 60898-1, offering a practical solution for residential and commercial distribution boards.

The Schneider Electric Acti9 iK60 range is designed to simplify both circuit protection and isolation. The A9K24263 reference can be mounted on DIN rail and supports power supply from either the top or the bottom, making it easy to integrate into different panel configurations.

63 A bipolar circuit breaker with C curve

The Schneider Electric A9K24263 features 2 poles with both poles protected and a rated current of 63 A at 30 °C. Its C tripping curve has a magnetic operating threshold between 5 and 10 times the rated current, a common characteristic for circuits with moderate inrush currents.

  • Number of poles: 2P.
  • Protected poles: 2.
  • Rated current: 63 A at 30 °C.
  • Tripping curve: C.
  • Tripping technology: thermal-magnetic.
  • Magnetic tripping threshold: 5-10 x In.
  • Network type: AC.
  • Frequency: 50/60 Hz.

Protection against overloads and short circuits

The automatic circuit breaker combines two protection systems. The thermal trip acts against sustained overloads that can cause excessive heating of the conductors, while the magnetic trip provides a fast response when a short circuit occurs.

This combination makes the iK60N suitable as a protection device for lines and electrical circuits within low-voltage distribution boards.

6 kA breaking capacity

The Acti9 iK60N A9K24263 offers a rated breaking capacity Icn of 6,000 A in accordance with EN/IEC 60898-1. The manufacturer specifies this capacity at both 230 V and 400 V AC, 50/60 Hz.

Its service breaking capacity Ics also reaches 6 kA, equivalent to 100% of the rated breaking capacity, under the conditions established by EN/IEC 60898-1.

  • Icn breaking capacity at 230 V AC: 6 kA.
  • Icn breaking capacity at 400 V AC: 6 kA.
  • Service breaking capacity Ics: 6 kA.
  • Limitation class: class 3.

Suitable for isolation

In addition to its protection functions, the Schneider Electric A9K24263 is suitable for isolation in accordance with EN/IEC 60898-1. This means it can be used to electrically isolate the protected circuit when maintenance or intervention work is required, always following the corresponding safety procedures.

Quick DIN rail mounting

The thermal-magnetic breaker is installed by clip-on mounting on a DIN rail, making it easy to fit inside modular electrical panels. Schneider Electric incorporates a double clip system that allows the device to be removed even when installed next to a compatible comb busbar.

The unit also allows top or bottom power supply, providing greater flexibility during panel wiring.

Compact 2-module format

The A9K24263 occupies 4 x 9 mm modules, equivalent to a width of 36 mm or 2 standard 18 mm modules. Its dimensions make it easy to integrate alongside other modular protection and control devices.

  • Height: 85 mm.
  • Width: 36 mm.
  • Depth: 78.5 mm.
  • Installation depth: 44.5 mm.
  • Approximate weight: 200 g.
  • Color: white RAL 9003.

Insulation and electrical resistance

The thermal-magnetic breaker has a rated insulation voltage Ui of 440 V AC and an impulse withstand voltage Uimp of 4 kV, features that help ensure proper insulation within low-voltage installations.

  • Rated insulation voltage Ui: 440 V AC.
  • Impulse withstand voltage Uimp: 4 kV.
  • Pollution degree: 2.
  • Overvoltage category: II.

Conductor connection

The terminals of the Schneider Electric A9K24263 allow connection of conductors with different cross-sections depending on their construction. It accepts up to 35 mm² for rigid conductors and up to 25 mm² for flexible conductors, making it suitable for circuits designed for high currents.

  • Rigid conductor cross-section: up to 35 mm².
  • Flexible conductor cross-section: up to 25 mm².
  • Tightening torque: 3.5 Nm.

High mechanical and electrical durability

The Acti9 iK60N is designed to provide a long service life inside the electrical panel. The A9K24263 reference offers mechanical durability of up to 20,000 cycles and electrical durability of up to 10,000 cycles under the conditions specified by the manufacturer.

IP20 protection

The automatic circuit breaker offers an IP20 protection rating when installed as a standalone device. Once mounted inside a suitable modular enclosure, it can achieve a protection rating of IP40, according to IEC/EN 60529.

The operating ambient temperature range is -25 to 60 °C, while the permitted storage temperature ranges from -40 to 85 °C.

Compliant with EN/IEC 60898-1

The Schneider Electric Acti9 iK60N A9K24263 thermal-magnetic circuit breaker is developed in accordance with EN/IEC 60898-1 for circuit breakers intended for overcurrent protection in electrical installations.

Technical characteristics of the Schneider Electric A9K24263

  • Brand: Schneider Electric.
  • Range: Acti9.
  • Series: Acti9 iK60.
  • Model: iK60N.
  • Reference: A9K24263.
  • Type: thermal-magnetic circuit breaker.
  • Application: electrical distribution.
  • Number of poles: 2P.
  • Protected poles: 2.
  • Rated current: 63 A at 30 °C.
  • Curve: C.
  • Tripping unit: thermal-magnetic.
  • Magnetic threshold: 5-10 x In.
  • Network type: AC.
  • Frequency: 50/60 Hz.
  • Icn breaking capacity: 6 kA.
  • Service breaking capacity Ics: 6 kA.
  • Limitation class: 3.
  • Insulation voltage Ui: 440 V AC.
  • Impulse withstand voltage Uimp: 4 kV.
  • Suitable for isolation: yes.
  • Control type: toggle lever.
  • Mounting: DIN rail.
  • Power supply: top or bottom.
  • Width: 36 mm.
  • Height: 85 mm.
  • Depth: 78.5 mm.
  • Approximate weight: 200 g.
  • Protection rating: IP20, up to IP40 in suitable enclosure.
  • Mechanical durability: 20,000 cycles.
  • Electrical durability: 10,000 cycles.
  • Operating temperature: -25 to 60 °C.
  • Storage temperature: -40 to 85 °C.
  • Standard: EN/IEC 60898-1.

The Schneider Electric Acti9 iK60N A9K24263 2-pole, 63 A, C-curve provides protection against overloads and short circuits in electrical distribution circuits. Its 6 kA breaking capacity, modular DIN rail format, top or bottom supply option, and high durability make it a suitable solution for residential and tertiary electrical panels.

Specifications
Manufacturer
SCHNEIDER ELECTRIC
Reference
A9K24263
SKU
SCHBEFD7823
Object
Automatic switch
Number of poles
2P
Assembly
Adjustable in DIN rail clip
Nominal current
63 A
Network type
CA
Protection rating
IP20
Color
White
Datasheets
Reviews
Returns within 30 days
Shop with peace of mind. If something goes wrong, we'll take care of it.
After-sales service
Any questions? Our support team will be happy to help you.
Pay how and when you want
Card, bank transfer, PayPal... Installment? We have them all.
GroupSumi is your online distributor for construction, electrical material and climate control.
All rights reserved © 2026 GroupSumi