The Schneider Electric Acti9 NG125N 18662 thermal-magnetic circuit breaker is a four-pole automatic breaker rated at 125 A with C curve, designed to protect low-voltage electrical circuits against overloads and short circuits. It features 4 poles with all 4 poles protected and delivers a high breaking capacity of 25 kA at 380-415 V AC according to EN/IEC 60947-2, making it especially suitable for high-power distribution boards in commercial and industrial installations.
Schneider Electric’s Acti9 NG125 range combines high interrupting capacity with a modular DIN rail format. Reference 18662 supports AC and DC networks, incorporates thermal-magnetic tripping, and includes mechanical trip indication to make it easy to identify the circuit that has operated.
The Schneider Electric 18662 has a 4P configuration with four protected poles. Its rated current is 125 A at 40 °C, so it is designed for distribution circuits with high current demands.
The Acti9 NG125N integrates a thermal-magnetic trip unit. Thermal protection acts against sustained overloads that could cause excessive heating of the conductors, while magnetic protection provides rapid disconnection when a high short-circuit current occurs.
Its C curve has a magnetic threshold of 8 times the rated current, in accordance with Schneider Electric specifications for this reference.
One of the main features of the Schneider Electric NG125N 18662 is its high breaking capacity. According to EN/IEC 60947-2, the ultimate interrupting capacity Icu varies depending on the operating voltage:
At 380-415 V AC, its service breaking capacity Ics reaches 18.75 kA, equivalent to 75% of Icu. This capacity makes it suitable for installations where high short-circuit currents may occur.
The circuit breaker is suitable for isolation according to EN/IEC 60947-2, so it can be used to isolate the protected circuit during maintenance operations carried out in accordance with the relevant safety procedures.
The front also includes contact position indication and mechanical trip signaling. The red indicator makes it possible to visually recognize that the breaker has operated due to an electrical fault.
The Acti9 NG125N 18662 offers insulation performance suitable for high-capacity low-voltage distribution installations.
The NG125N can be complemented with a compatible residual current block from the Schneider Electric range when the installation requires additional protection against earth leakage currents.
Residual current protection is not integrated into the 18662 circuit breaker and must be selected separately, taking into account the number of poles, rated current, sensitivity, and residual current class required by the installation.
The Schneider Electric NG125N is designed for clip-on mounting on a 35 mm symmetrical DIN rail. Its four-pole format occupies 12 modules of 9 mm, equivalent to a total width of 108 mm.
Its construction makes it possible to integrate 125 A protection with high breaking capacity into modular panels, avoiding the need for considerably larger devices when the installation characteristics allow the NG125 range to be used.
Due to its 125 A rated current, the circuit breaker includes terminals sized for large cross-section conductors. According to the available specifications for this reference, it accepts rigid conductors up to 70 mm² and flexible conductors up to 50 mm².
The Schneider Electric Acti9 NG125N is designed to withstand a high number of operations throughout its service life. Reference 18662 achieves mechanical durability of up to 20,000 cycles and electrical durability of up to 5,000 cycles.
The device is also prepared for padlock locking, a useful feature for lockout and maintenance operations in professional installations.
The breaker measures 108 mm wide, 103 mm high, and 81 mm deep, with an approximate weight of 0.96 kg.
The NG125N is designed to operate in demanding environmental conditions inside properly sized electrical panels.
The Schneider Electric Acti9 NG125N 18662 4-pole, 125 A, C-curve is a high-capacity protection solution for distribution circuits that require high current ratings and significant breaking capacity. Its 25 kA at 380-415 V AC, thermal-magnetic protection, four protected poles, 690 V insulation, and DIN rail mounting make it an especially suitable choice for electrical panels in the commercial and industrial sectors.