The Schneider Electric TeSys K LP1K0901BD mini contactor is a compact 3-pole contactor with 3 normally open main contacts, designed for controlling motors and resistive loads in electrical panels and automation systems. It offers a rated current of 9 A in AC-3 category up to 440 V, can switch motors up to 4 kW at 380-415 V, and includes a standard 24 V DC coil. It also features 1 normally closed NC auxiliary contact, screw terminals, and a compact body only 45 mm wide.
The LP1K0901BD reference belongs to Schneider Electric's TeSys K range, developed for compact control systems in industrial, infrastructure, and building applications. Its 24 V DC control supply makes it easy to integrate with automation circuits, relays, and controllers, while DIN rail or panel mounting allows it to adapt to different panel architectures.
The LP1K0901BD incorporates 3 normally open main contacts. When the coil receives 24 V DC, the three poles close simultaneously to supply the load; when the control voltage is removed, they return to the open position.
In AC-3 category, Schneider Electric specifies different motor power ratings depending on the voltage:
In a typical 400 V three-phase network, the mini contactor can therefore control a motor up to 4 kW, provided the rated current and starting conditions are compatible with the device's 9 A AC-3 rating.
The LP1K0901BD reference includes a 24 V DC control coil. Schneider Electric classifies it as a standard DC coil.
24 V DC supply is especially suitable for automation panels, machinery, and control systems where this voltage is commonly used as the control voltage.
Schneider Electric specifies for the coil:
These values should be considered when sizing the 24 V DC power supply and the outputs or relays used to control the contactor.
In addition to the three power poles, the LP1K0901BD includes as standard 1 instantaneous normally closed auxiliary contact.
This auxiliary contact can be used for signaling, interlocking, status feedback, or control sequences.
It is important to distinguish it from the main contacts: the 3 main NO contacts perform the power switching, while the 1 NC auxiliary is intended for signaling or control circuits.
In addition to motor control, the TeSys K can switch resistive or weakly inductive loads.
Schneider Electric specifies:
The AC-1 values must not be confused with the 9 A AC-3 rating, since each category corresponds to a different load type and switching conditions.
The LP1K0901BD is specified for the AC-1, AC-3 and AC-4 utilization categories.
In AC-4 at 400 V, Schneider Electric specifies a motor power rating of 2.2 kW.
The official datasheet specifies a rated making capacity of 110 A AC in accordance with IEC 60947.
The rated breaking capacity of the power circuit varies according to voltage:
These figures correspond to the contactor's switching performance and are not a short-circuit breaking capacity.
The LP1K0901BD is a switching device. It does not itself provide overload or short-circuit protection.
Schneider Electric specifies the following associated protection devices:
For motor applications, it can be combined with TeSys motor circuit breakers or thermal overload relays correctly sized and coordinated.
The mini contactor uses screw terminals. Depending on the type and number of conductors, it accepts:
The TeSys K LP1K0901BD can be installed on either a DIN rail or directly on a mounting plate.
This flexibility makes it suitable for small automation panels, machine enclosures, and compact equipment.
The compact size of the TeSys K range allows a three-phase contactor with integrated auxiliary contact to be installed in panels where space is limited.
Schneider Electric specifies a maximum operating frequency of 3,600 cycles per hour within the conditions established for the device.
The indicated operating times are:
The LP1K0901BD offers a long service life:
Actual durability depends on current, voltage, utilization category, switching frequency, and environmental conditions.
The main dielectric characteristics include:
The technical documentation specifies a IP2X degree of protection according to VDE 0106. The mini contactor is intended to be installed inside a panel or enclosure that provides the required environmental protection level.
Thanks to its compact format, 9 A AC-3 rating, and 24 V DC coil, this mini contactor can be integrated into many automation applications:
The Schneider Electric TeSys K LP1K0901BD combines three power poles, 9 A AC-3, motor capacity up to 4 kW at 400 V, and a standard 24 V DC coil in a body measuring only 45 x 58 x 57 mm. The integrated NC auxiliary contact makes signaling and interlocking functions easier without the need to add an external contact initially.
Its DIN rail or panel mounting, switching frequency of up to 3,600 cycles/h, and high durability make it a practical solution for machinery, pumping, ventilation, and automation systems with 24 V DC control.
Important: the LP1K0901BD is a switching and control device, not a motor protection device. It does not protect on its own against overloads or short circuits, so it must be combined with a motor circuit breaker, thermal overload relay, fuses, or an appropriately rated circuit breaker for the load and installation.