Contactor 18A 1 NO/1 NC 230V 50-60HZ with reference LC1D18P7 from the brand SCHNEIDER ELECTRIC
Contactor 18A 1 NO/1 NC 230V 50-60HZ with reference LC1D18P7 from the brand SCHNEIDER ELECTRIC
SCHNEIDER ELECTRIC

Contactor 18A 1 NO/1 NC 230V 50-60HZ

REF
LC1D18P7
(0)
67.00 €
€67.00
€170.38
Up to -6% for professionals. Discover it.
Schneider Electric TeSys Deca LC1D18P7 contactor 3P 18 A AC-3, 7.5 kW at 400 V, 230 V AC 50/60 Hz coil, 1 NO + 1 NC auxiliaries, and screw terminals for motor control.
Buy now and receive it between 20 and November 23
Express delivery
Get +67 +134 Sumis for the purchase
Receive 2x Sumis for a limited time
More about the product

Information about Contactor 18A 1 NO/1 NC 230V 50-60HZ

The Schneider Electric TeSys Deca LC1D18P7 contactor is a power electromagnetic contactor designed for motor control and resistive loads. It features 3 poles with 3 normally open main contacts, a rated operational current of 18 A in AC-3 and AC-3e categories up to 440 V, and a 230 V AC control coil at 50/60 Hz. In motor applications, it can control up to 7.5 kW at 380-400 V and includes as standard 1 NO auxiliary contact + 1 NC auxiliary contact.

The LC1D18P7 reference belongs to the TeSys Deca family, traditionally also marketed as TeSys D, and is intended for industrial applications, machinery, and HVAC systems. Its compact 45 mm width, screw terminals, and the option for DIN rail or panel mounting make it easy to integrate into motor starters and automation panels.

18 A three-pole contactor

The LC1D18P7 incorporates 3 normally open main contacts designed to connect and disconnect the three phases of a three-phase load simultaneously.

In AC-3/AC-3e category, Schneider Electric specifies a rated operational current of 18 A up to 440 V AC, within the contactor’s rated conditions.

AC-3 is especially associated with starting and stopping squirrel-cage asynchronous motors, where the contactor withstands inrush current during closing and opens when the motor is running under normal conditions.

Up to 7.5 kW at 400 V

The permissible motor power depends on the supply voltage. Schneider Electric specifies for this reference:

  • 220-230 V AC: 4 kW.
  • 380-400 V AC: 7.5 kW.
  • 415-440 V AC: 9 kW.
  • 500 V AC: 10 kW.
  • 660-690 V AC: 10 kW.

On a typical 400 V three-phase network, the LC1D18P7 can therefore control motors up to 7.5 kW in AC-3, provided the motor rated current and starting conditions are compatible.

230 V AC 50/60 Hz coil

The suffix P7 identifies the version equipped with a 230 V AC control coil at 50/60 Hz.

The coil allows the contactor to be controlled by devices such as pushbuttons, relays, pressure switches, thermostats, limit switches, automation systems, or compatible controllers.

When the coil is energized, the electromagnetic mechanism closes the three main contacts. When control power is removed, the contacts return to their open position.

Integrated 1 NO + 1 NC auxiliary contacts

In addition to the three power main contacts, the LC1D18P7 integrates:

  • 1 normally open auxiliary contact.
  • 1 normally closed auxiliary contact.

Therefore, the correct contactor composition is:

  • Main contacts: 3 NO.
  • Auxiliary contacts: 1 NO + 1 NC.

The auxiliary contacts can be used for self-holding, signaling, feedback to a PLC, electrical interlocking, or automation sequences.

Mechanically linked auxiliary contacts

Schneider Electric specifies that the 1 NO + 1 NC auxiliary contacts are mechanically linked in accordance with IEC 60947-5-1.

The normally closed contact also includes a mirror contact characteristic in accordance with IEC 60947-4-1, useful in certain monitoring systems when the complete electrical scheme has been designed to take advantage of this function.

32 A for AC-1 loads

In addition to motor control, the LC1D18P7 can be used for certain resistive or slightly inductive loads.

In AC-1 category, Schneider Electric specifies a rated operational current of up to 32 A at voltages up to 440 V.

This value should not be confused with the 18 A in AC-3, since AC-1 and AC-3 correspond to different load types and switching conditions.

Utilization categories AC-1, AC-3, AC-3e and AC-4

The contactor can be used in different utilization categories depending on the load:

  • AC-1: resistive or slightly inductive loads.
  • AC-3: normal starting and stopping of asynchronous motors.
  • AC-3e: updated category for certain motor control applications.
  • AC-4: more demanding motor switching, such as inching or certain reversing operations.

For AC-4 applications at 400 V, Schneider Electric specifies a motor power of approximately 4 kW.

Power circuit up to 690 V AC

The LC1D18P7 main circuit supports:

  • Operational voltage: up to 690 V AC.
  • Power circuit frequency: 25-400 Hz.
  • Direct current voltage: up to 300 V DC depending on configuration.
  • Rated impulse withstand voltage Uimp: 6 kV.

The specific electrical characteristics must always be checked according to the utilization category, voltage, and connected load.

Screw connection terminals

The LC1D18P7 reference uses screw terminals for the power circuit and control circuit, providing a conventional and robust connection inside the electrical panel.

The specified tightening torque for the main and control terminals is approximately 1.7 Nm, depending on the conductor and tool used.

DIN rail or panel mounting

The contactor can be installed by:

  • DIN rail mounting.
  • Direct panel mounting.

This flexibility makes it suitable for both small automation panels and larger industrial enclosures.

Compact 45 mm format

The Schneider Electric LC1D18P7 has compact dimensions:

  • Width: 45 mm.
  • Height: 77 mm.
  • Depth: 86 mm.
  • Approximate weight: 0.33 kg.

The width of only 45 mm allows several contactors to be installed in limited spaces and facilitates the creation of compact starters.

High mechanical and electrical durability

The TeSys Deca LC1D18P7 is designed to withstand a high number of operations:

  • Mechanical durability: up to 15 million cycles.
  • Electrical durability in AC-3: approximately 1.65 million cycles at 18 A and up to 440 V.
  • Electrical durability in AC-1: approximately 1 million cycles at 32 A and up to 440 V.
  • Maximum switching frequency: up to 3,600 cycles per hour at 60 °C.

Coil consumption

The standard AC coil has approximately:

  • Inrush power at 50 Hz: 70 VA.
  • Inrush power at 60 Hz: 70 VA.
  • Holding power at 50 Hz: 7 VA.
  • Holding power at 60 Hz: 7.5 VA.
  • Thermal dissipation: approximately 2-3 W.

The coil does not include an integrated surge suppression module as standard. When required by the application, compatible suppression accessories from the TeSys range can be used.

Fast operating times

Schneider Electric specifies approximate switching times of:

  • Closing: 12-22 ms.
  • Opening: 4-19 ms.

These times allow the contactor to be integrated into automation systems with fast and repetitive sequences.

IP20 protection rating

The front face of the LC1D18P7 has an IP20 protection rating in accordance with IEC 60529.

The contactor is designed to be installed inside an enclosure or electrical cabinet that provides the required protection against the environment and access to live parts.

Environmental conditions

The specified environmental conditions for the contactor include:

  • Normal operating ambient temperature: -5 to 60 °C.
  • Storage temperature: -60 to 80 °C.
  • Maximum altitude without temperature derating: up to 3,000 m.
  • Pollution degree: 3.

Applications of the Schneider Electric LC1D18P7

The contactor can be properly sized and integrated into applications such as:

  • Three-phase motors.
  • Pumps.
  • Fans and extractors.
  • Compressors.
  • HVAC systems.
  • Industrial machinery.
  • Conveyor systems.
  • Automation panels.
  • Direct-on-line motor starters.
  • Compatible resistive loads.

Compatible with TeSys accessories

The LC1D18P7 is part of the TeSys platform and can be combined with different compatible accessories, such as:

  • Thermal overload relays.
  • Auxiliary contact blocks.
  • Timers.
  • Coil suppression modules.
  • Mechanical interlocks.
  • Connection accessories.
  • Compatible motor protection devices.

The reference for each accessory should be checked according to the required current, voltage, function, and coordination.

Technical characteristics of the Schneider Electric LC1D18P7

  • Brand: Schneider Electric.
  • Reference: LC1D18P7.
  • Range: TeSys Deca.
  • Traditional name: TeSys D.
  • Type: power contactor.
  • Application: motor control and resistive loads.
  • Number of poles: 3P.
  • Main contacts: 3 NO.
  • Auxiliary contacts: 1 NO + 1 NC.
  • AC-3/AC-3e current: 18 A up to 440 V.
  • AC-1 current: 32 A up to 440 V.
  • Power at 220-230 V AC-3: 4 kW.
  • Power at 380-400 V AC-3: 7.5 kW.
  • Power at 415-440 V AC-3: 9 kW.
  • Power at 500 V AC-3: 10 kW.
  • Power at 660-690 V AC-3: 10 kW.
  • Power at 400 V AC-4: 4 kW.
  • Coil voltage: 230 V AC.
  • Coil frequency: 50/60 Hz.
  • Maximum power circuit voltage: 690 V AC.
  • Maximum DC voltage: 300 V DC depending on configuration.
  • Rated impulse withstand voltage Uimp: 6 kV.
  • Utilization categories: AC-1, AC-3, AC-3e and AC-4.
  • Coil technology: standard AC, without integrated suppressor.
  • Terminals: screw terminals.
  • Tightening torque: approximately 1.7 Nm.
  • Mounting: DIN rail or panel.
  • Width: 45 mm.
  • Height: 77 mm.
  • Depth: 86 mm.
  • Weight: approximately 0.33 kg.
  • Mechanical durability: up to 15 million cycles.
  • Electrical durability AC-3: approximately 1.65 million cycles.
  • Maximum switching frequency: 3,600 cycles/h.
  • Closing time: 12-22 ms.
  • Opening time: 4-19 ms.
  • Inrush consumption: approximately 70 VA.
  • Holding consumption: 7-7.5 VA.
  • Coil dissipation: approximately 2-3 W.
  • Front protection rating: IP20.
  • Operating temperature: -5 to 60 °C.
  • Storage temperature: -60 to 80 °C.
  • Altitude: up to 3,000 m without temperature derating.
  • EAN: 3389110349535.
  • Main standards: IEC/EN 60947-4-1 and IEC/EN 60947-5-1.

Compact contactor for motors up to 7.5 kW at 400 V

The Schneider Electric TeSys Deca LC1D18P7 combines an AC-3/AC-3e current rating of 18 A, motor capacity up to 7.5 kW at 400 V, and a 230 V AC coil in a compact 45 mm-wide format. The integrated 1 NO + 1 NC auxiliary contacts make it easy to create interlocking and signaling circuits.

Its high mechanical durability, screw terminals, DIN rail or panel mounting, and the wide range of TeSys accessories make it easy to integrate into panels for machinery, pumps, fans, compressors, and HVAC systems.

Important: the LC1D18P7 is a switching and control device and does not itself provide overload or short-circuit protection. In motor applications, it must be combined with a motor protection switch, thermal overload relay, fuses, or a circuit breaker correctly sized for the characteristics of the motor and installation.

Specifications
Manufacturer
SCHNEIDER ELECTRIC
Reference
LC1D18P7
SKU
SCH4F3B7A2B
Object
Contactor
Number of poles
3 NA
Assembly
Plate. Profile
Frequency
50.00 - 60.00 Hz
Warranty
18 months
Compliance with RoHS
YES
Number of contacts
1 NA + 1 NC A
Datasheets
Reviews
Returns within 30 days
Shop with peace of mind. If something goes wrong, we'll take care of it.
After-sales service
Any questions? Our support team will be happy to help you.
Pay how and when you want
Card, bank transfer, PayPal... Installment? We have them all.
GroupSumi is your online distributor for construction, electrical material and climate control.
All rights reserved © 2026 GroupSumi