Contactor 18A 1 NO/1 NC 24V DC-AR with reference LC1D18BD from the brand SCHNEIDER ELECTRIC
Contactor 18A 1 NO/1 NC 24V DC-AR with reference LC1D18BD from the brand SCHNEIDER ELECTRIC
SCHNEIDER ELECTRIC

Contactor 18A 1 NO/1 NC 24V DC-AR

REF
LC1D18BD
(0)
124.50 €
€124.50
€300.90
Up to -6% for professionals. Discover it.
Schneider Electric TeSys Deca LC1D18BD contactor, 18 A, 3 poles, 24 V DC coil and 1 NO + 1 NC auxiliaries, for motors up to 7.5 kW at 400 V.
Buy now and receive it between 10 and December 14
Get +125 +249 Sumis for the purchase
Receive 2x Sumis for a limited time
More about the product

Information about Contactor 18A 1 NO/1 NC 24V DC-AR

The Schneider Electric TeSys Deca LC1D18BD contactor is an electromechanical device with 3 poles and 18 A, designed for switching motors and resistive loads in electrical panels and automation systems. It features 3 normally open main contacts, a 24 V DC control coil, and integrated auxiliary contacts 1 NO + 1 NC, offering a compact and versatile solution for industrial, commercial, and HVAC applications.

In AC-3 and AC-3e utilization category, the LC1D18BD supports a rated current of 18 A up to 440 V AC and can control three-phase motors up to 7.5 kW at 380-400 V. For resistive loads in AC-1 category, its thermal current rating reaches 32 A under the conditions specified by Schneider Electric.

18 A TeSys Deca Contactor

The LC1D18BD reference is part of Schneider Electric's TeSys Deca range, developed for the control and switching of electric motors and other loads in professional installations. Its three main poles allow simultaneous connection and disconnection of the three phases of a three-phase circuit.

  • Number of poles: 3P.
  • Main contacts: 3 NO.
  • Rated current AC-3/AC-3e: 18 A up to 440 V AC.
  • Rated current AC-1: 32 A up to 440 V AC.
  • Applications: motor control and resistive loads.

24 V DC Control Coil

The LC1D18BD incorporates a 24 V DC coil, especially suitable for automation circuits using low-voltage control.

The coil includes an integrated suppression device, designed to limit overvoltages generated when the coil is de-energized and to improve integration with other electronic components in the control circuit.

  • Coil voltage: 24 V DC.
  • Control circuit type: direct current.
  • Suppression device: integrated.
  • Inrush power consumption: approximately 5.4 W at 20 °C.
  • Holding power consumption: approximately 5.4 W at 20 °C.

Integrated 1 NO + 1 NC Auxiliary Contacts

In addition to the three power contacts, the contactor includes as standard one normally open auxiliary contact and one normally closed auxiliary contact. These contacts make it easier to implement interlocking, status signaling, and other functions within the control circuit.

The NC contact has a mirror contact function according to IEC 60947-4-1, while the NO and NC contacts are mechanically linked according to IEC 60947-5-1.

Motor Power by Voltage

The maximum motor power depends on the supply voltage and utilization category. In AC-3/AC-3e applications, Schneider Electric specifies the following power ratings:

  • 220-230 V AC: up to 4 kW.
  • 380-400 V AC: up to 7.5 kW.
  • 415-440 V AC: up to 9 kW.
  • 500 V AC: up to 10 kW.
  • 660-690 V AC: up to 10 kW.

In AC-4 category at 400 V AC, used for more demanding operations such as plugging, inching, or braking, the motor power indicated by the manufacturer is 4 kW.

AC-1, AC-3, AC-3e and AC-4 Utilization Categories

The Schneider Electric LC1D18BD supports different utilization categories, allowing it to be adapted to various load and switching types:

  • AC-1: non-inductive or slightly inductive loads.
  • AC-3: starting and switching off squirrel-cage motors during normal operation.
  • AC-3e: control of high-efficiency motors.
  • AC-4: demanding operations such as inching, plugging, or braking.

Power Circuit up to 690 V AC

The contactor power circuit supports a rated operating voltage of up to 690 V AC, with frequencies between 25 and 400 Hz. It also supports DC applications up to 300 V DC within the limits specified by Schneider Electric.

  • Maximum operating voltage in AC: 690 V.
  • Power circuit frequency: 25-400 Hz.
  • Maximum voltage in DC: 300 V.
  • Rated insulation voltage: 690 V according to IEC 60947.
  • Impulse withstand voltage: 6 kV.
  • Overvoltage category: III.

High Switching Capacity and Durability

The TeSys Deca LC1D18BD is designed for frequent switching in industrial and automation applications. Schneider Electric states a mechanical durability of up to 30 million cycles.

Under AC-3 conditions at 18 A and up to 440 V, its electrical durability reaches approximately 1.65 million cycles. The maximum operating frequency is up to 3,600 cycles per hour at 60 °C.

Screw Terminal Connection

The contactor uses screw terminals for both the power circuit and the control circuit. This system ensures a secure connection and makes installation and maintenance easier.

  • Power conductor cross-section: up to 6 mm² depending on conductor type and terminal.
  • Control circuit cross-section: up to 4 mm² depending on configuration.
  • Tightening torque: 1.7 Nm.

DIN Rail or Panel Mounting

The LC1D18BD can be installed directly on a DIN rail or mounted on a panel. Its 45 mm width makes it easy to integrate into electrical panels alongside thermal overload relays, protection devices, auxiliaries, and other TeSys components.

  • Mounting: DIN rail or panel.
  • Width: 45 mm.
  • Height: 77 mm.
  • Depth: 95 mm.
  • Net weight: approximately 0.49 kg.

Compatible with TeSys Thermal Overload Relays

The TeSys Deca range allows the contactor to be combined with compatible Schneider Electric thermal overload relays to create a complete motor switching and protection assembly against overloads and phase failures.

This modular architecture makes it easier to select the appropriate protection according to the motor's rated current and allows compact starters to be built for professional electrical panels.

IP20 Protection and Environmental Resistance

The front of the contactor offers an IP20 protection rating in accordance with IEC 60529. The device is designed to operate in industrial environments and withstand vibration, shock, and temperature variations within the limits established by Schneider Electric.

  • Front protection rating: IP20.
  • Operating ambient temperature: -40 °C to 60 °C without derating.
  • Operation with derating: up to 70 °C.
  • Operating altitude: up to 3,000 m.
  • Pollution degree: 3.
  • Fire resistance: 850 °C according to IEC 60695-2-1.
  • Flame retardancy: V1 according to UL 94.

Standards and Certifications

The Schneider Electric LC1D18BD complies with various international standards applicable to contactors and electromechanical control devices.

  • IEC/EN 60947-4-1.
  • IEC/EN 60947-5-1.
  • IEC 60335-1.
  • UL 508.
  • CSA C22.2 No. 14.

Technical Features of the Schneider Electric LC1D18BD

  • Brand: Schneider Electric.
  • Range: TeSys Deca.
  • Reference: LC1D18BD.
  • Type: electromechanical contactor.
  • Application: motor control and resistive loads.
  • Number of poles: 3P.
  • Main contacts: 3 NO.
  • Auxiliary contacts: 1 NO + 1 NC.
  • Rated current AC-3/AC-3e: 18 A.
  • Rated current AC-1: 32 A.
  • Motor power at 380-400 V: 7.5 kW.
  • Motor power at 415-440 V: 9 kW.
  • Coil voltage: 24 V DC.
  • Coil suppression: integrated.
  • Maximum operating voltage: 690 V AC.
  • Insulation voltage: 690 V.
  • Impulse withstand voltage: 6 kV.
  • Mechanical durability: 30 million cycles.
  • Electrical durability AC-3: approximately 1.65 million cycles.
  • Maximum switching frequency: 3,600 cycles/h.
  • Mounting: DIN rail or panel.
  • Terminals: screw terminals.
  • Front protection rating: IP20.
  • Dimensions: 45 x 77 x 95 mm.
  • Net weight: approximately 0.49 kg.

24 V DC Contactor for Motors and Automation

The Schneider Electric TeSys Deca LC1D18BD offers a robust solution for switching motors and electrical loads. Its combination of 18 A in AC-3/AC-3e, 24 V DC coil with integrated suppression, 1 NO + 1 NC auxiliary contacts, and capacity for motors up to 7.5 kW at 400 V makes it suitable for numerous automation systems and control panels.

Its high durability, DIN rail or panel mounting, and compatibility with TeSys accessories and thermal overload relays make it easy to build professional switching and protection solutions tailored to industrial installations, machinery, pumping, ventilation, and HVAC.

Specifications
Manufacturer
SCHNEIDER ELECTRIC
Reference
LC1D18BD
SKU
SCHDB34EF6B
Object
Contactor
Number of poles
3 NA
Assembly
Plate. Profile
Warranty
18 months
Compliance with RoHS
YES
Number of contacts
1 NA + 1 NC A
Operating temperature
-20.00 - 60.00 °C
Datasheets
Reviews
Returns within 30 days
Shop with peace of mind. If something goes wrong, we'll take care of it.
After-sales service
Any questions? Our support team will be happy to help you.
Pay how and when you want
Card, bank transfer, PayPal... Installment? We have them all.
GroupSumi is your online distributor for construction, electrical material and climate control.
All rights reserved © 2026 GroupSumi