The Schneider Electric LC1D32F7 contactor from the TeSys D / TeSys Deca range is a three-pole contactor designed for motor control and resistive loads in industrial, commercial, and automation systems. It offers a rated operational current of 32 A in AC-3 category up to 440 V, includes a 110 V AC control coil at 50/60 Hz, and can control three-phase motors up to 15 kW at 380-400 V.
The device features 3 normally open main contacts for the power circuit and 1 normally open auxiliary contact + 1 normally closed auxiliary contact integrated. This configuration makes it easy to implement interlocking, signaling, and automation circuits without needing to install an additional auxiliary block from the outset.
The LC1D32F7 is specifically designed for starting and stopping electric motors. In AC-3 category, it supports a rated current of 32 A up to 440 V AC at temperatures up to 60 °C, allowing it to control asynchronous motors within the conditions specified by Schneider Electric.
AC-3 category covers common applications where the contactor closes on the motor starting current and opens when the motor is running normally. For this reason, this reference is suitable for pumps, fans, compressors, machinery, and many electrical drives.
The maximum motor power depends on the supply voltage. Schneider Electric specifies for the LC1D32F7:
In a typical 400 V three-phase installation, this reference can therefore control motors up to 15 kW in AC-3 category, provided that the rated current and the actual motor characteristics remain within the contactor limits.
The F7 version includes an electromagnetic coil rated at 110 V AC at 50/60 Hz. This control voltage makes it easy to integrate into automation panels and control circuits operating at 110 V.
When the coil is energized, the contactor actuates its power and auxiliary contacts simultaneously. When the control signal disappears, the mechanism returns to its rest position.
Schneider Electric specifies a coil operating range of approximately 0.8 to 1.1 times Uc at 50 Hz and 0.85 to 1.1 times Uc at 60 Hz, within the temperature conditions indicated by the manufacturer.
The main circuit has three normally open contacts, one for each phase. These contacts are responsible for connecting and disconnecting the three-phase load supply.
It is important to distinguish these three main contacts from the 1 NO + 1 NC indicated in the commercial title, which correspond to the standard integrated auxiliary contacts.
The LC1D32F7 includes one normally open auxiliary contact and one normally closed auxiliary contact as standard. They can be used for different automation functions:
The auxiliary contacts are mechanically linked in accordance with IEC 60947-5-1. The NC contact also features mirror contact function in accordance with IEC 60947-4-1.
The permissible current depends on the nature of the load and the utilization category:
AC-3 is mainly intended for motor switching, while AC-1 applies to non-inductive or slightly inductive loads. Therefore, the contactor must always be selected considering the utilization category as well as the rated current.
The power circuit supports a rated operational voltage of up to 690 V AC between 25 and 400 Hz. Schneider Electric also allows use in direct current up to 300 V within the specified configurations.
The rated insulation voltage is 690 V according to IEC 60947-4-1 and the rated impulse withstand voltage Uimp is 6 kV, with overvoltage category III.
The contactor offers a rated making capacity of 550 A at 440 V for the power circuit in accordance with IEC 60947. The rated breaking capacity is also 550 A at 440 V.
These performance values allow it to withstand the transient currents generated during motor switching and other compatible loads.
Schneider Electric specifies a conventional free-air thermal current Ith of 50 A at temperatures up to 60 °C for the main circuit.
For the signaling auxiliary circuit, the specified conventional thermal current is 10 A at 60 °C.
The TeSys LC1D32F7 is designed for a high number of operations:
These performance values make it suitable for automation applications with repetitive switching over long service periods.
The coil requires higher power during the initial closing instant and lower consumption once the contactor is held in the energized position.
These values should be considered when sizing transformers, relays, or circuits used to supply the control coil.
Schneider Electric specifies reduced operating times:
This speed allows it to respond immediately to signals from the control circuit in automation applications.
The LC1D32F7 offers two main installation options:
This flexibility makes it easy to integrate into both compact electrical panels and larger industrial automation cabinets.
The power and control circuits use screw terminals. For the power circuit, Schneider Electric allows connections of up to 10 mm² depending on the type and number of conductors used.
The specified tightening torque is approximately:
The final conductor cross-section must be calculated according to load current, installation method, temperature, and applicable regulations.
The contactor has reduced dimensions to help maximize available panel space:
Its format allows several contactors and control devices to be installed in a reduced space while maintaining an orderly layout.
The front face of the LC1D32F7 has an IP20 protection rating according to IEC 60529. It must be installed inside a suitable enclosure that provides the degree of protection required by the operating environment.
The contactor also includes a protective cover and TH protection treatment in accordance with IEC 60068-2-30.
The contactor is designed to operate under a wide range of conditions:
The LC1D32F7 can be combined with Schneider Electric TeSys accessories and components to create complete switching, protection, and automation solutions, including:
This modularity makes it easy to adapt the contactor to different motor control and industrial automation architectures.
Thanks to its 32 A rating and 110 V coil, it can be used in many professional applications:
The contactor is designed in accordance with different international standards applicable to switching and control devices:
Schneider Electric documentation also lists international certifications such as UL, CSA, CCC, DNV, BV, RINA, and Lloyd's Register, among others.
The Schneider Electric LC1D32F7 combines a rated current of 32 A in AC-3, capability for three-phase motors up to 15 kW at 400 V, and a 110 V AC 50/60 Hz control coil. Its three normally open main contacts perform the power switching, while the integrated 1 NO + 1 NC auxiliary contacts facilitate interlocking, signaling, and system control.
Its 45 mm width, DIN rail or plate mounting, high durability, and compatibility with TeSys accessories make this contactor a versatile solution for motor control panels, pumps, fans, machinery, HVAC, and industrial automation.
The final selection should be made taking into account the actual load power and current, utilization category, mains voltage, switching frequency, and environmental conditions of the installation.