The Schneider Electric Harmony Time RE17RAMU modular timer relay is a control device designed to introduce an on-delay timing function in electrical circuits and automation systems. It features 1 changeover output contact rated at 8 A, universal power supply of 24 to 240 V AC at 50/60 Hz or 24 V DC, and multiple timing ranges that allow adjustment from 0.1 seconds to 100 hours. Its compact 17.5 mm modular format makes installation on DIN rail easy in automation panels, machinery, buildings, HVAC systems, and other control applications.
The RE17RAMU reference currently belongs to Schneider Electric’s Harmony Timer Relays / Harmony Time family, previously identified in technical documentation as Zelio Time. It includes front selector and adjustment controls, LED indication, screw terminals, and a transparent cover that helps protect the settings against accidental changes.
The main function of the RE17RAMU is to delay the operation of its output contact for a previously configured time.
In standard on-delay operation, the sequence is:
This function makes it possible to introduce controlled delays in electrical schemes without needing a PLC or programmable controller for simple tasks.
Schneider Electric specifies the A and At timing functions for this reference.
Timing starts when power is applied. Once the set time has elapsed, the output relay changes state.
This function is suitable for applications such as:
The At function allows cumulative timing through a control signal. The time can be interrupted and resumed, accumulating the different periods until the previously set T value is reached.
This function is useful when the total operating time must be counted across several separate intervals.
The Schneider Electric RE17RAMU offers several selectable ranges that cover an extremely wide timing interval:
Thanks to these ranges, a single reference can be used for both very short delays and multi-hour timing cycles, reducing the number of different models needed in stock or maintenance.
Configuration is carried out directly from the front using rotary selectors and potentiometers.
The installer can select the desired range and then adjust the time within that range. This system simplifies commissioning and avoids the need for external software or programming tools.
The transparent front cover helps protect the settings from unintended changes once commissioning is complete.
The RE17RAMU includes 1 C/O changeover contact, also known as an inverse contact or SPDT contact.
This contact includes:
This allows it to be used both to activate a load once the time has elapsed and to perform the reverse function within the control circuit.
Schneider Electric specifies a maximum switching current of 8 A.
Main contact characteristics include:
The actual permissible current may be lower for inductive loads, contactors, solenoid valves, and other receivers with high inrush current. When the load exceeds the contact rating, a suitably sized intermediate contactor or relay must be used.
An important feature of this reference is its wide AC supply range.
This allows the same relay to be used in many control panels powered at different AC voltages.
Important: although some commercial descriptions summarize the supply as "24-240 V AC/DC", the technical datasheet specifies the full 24-240 V range for AC only; for DC, the indicated nominal voltage is 24 V DC.
Schneider Electric specifies the following timing performance:
These characteristics provide repeatable timed sequences in industrial and building control applications.
The RE17RAMU features front LED indication that makes it easy to visually diagnose the timer status.
Schneider Electric uses different lighting patterns to show:
This indication simplifies commissioning and helps quickly locate issues within the control circuit.
The RE17RAMU reference uses screw terminals for power supply, control signal, and output contact.
Depending on the number and type of conductors, it accepts:
The Schneider Electric RE17RAMU has a very compact format, similar in width to a single-pole modular device.
Its reduced size makes it possible to add timing functions without taking up a significant amount of space inside the electrical panel.
The device is designed for mounting on a 35 mm DIN rail in accordance with EN/IEC 60715.
It can be installed in different positions relative to the normal vertical plane, making integration into control cabinets and compact panels easier.
The RE17RAMU is designed to withstand a high number of operations:
Actual electrical durability depends on current, voltage, load type, and switching frequency.
Schneider Electric specifies different protection levels depending on the device area:
The timer is intended for installation inside an enclosure or cabinet that provides the protection level required by the installation environment.
The relay can operate across a wide range of environmental conditions:
The Schneider Electric RE17RAMU is designed for use in automation environments and meets requirements for resistance to vibration, shock, and electromagnetic disturbances.
The wide timing range and modular format make the RE17RAMU suitable for many control applications, always respecting the output contact rating.
The Schneider Electric Harmony Time RE17RAMU makes it possible to add on-delay timing with a wide adjustment range without resorting to more complex programmable systems. Its different ranges from 0.1 seconds to 100 hours allow a single model to adapt to many operating sequences.
Its 8 A changeover contact, multi-voltage AC supply, 24 V DC input, LED indication, and 17.5 mm format make it a particularly practical solution for automation panels, machinery, and installation control.
Important: the RE17RAMU is a control and timing device. It does not provide protection against overloads, short circuits, or earth leakage. The load and circuit must include the appropriate protection devices and, when the power or nature of the load exceeds the permissible capacity of the timer contact, a properly rated power relay or contactor must be used.