The Mecalia DPAC/DI/MCL wall-mounted buffer tank of 100 liters, reference 12508, is designed to store cold or hot water from the primary circuit of heating and air conditioning systems. Made of carbon steel, it operates at a maximum pressure of 6 bar and a temperature of up to 90 °C, making it a solution especially suitable for installations with heat pumps, boilers, solar energy or chilled water production equipment.
Its main function is to provide volume and thermal inertia to the hydraulic circuit, helping to stabilize the operation of the generator and to temporarily store thermal energy. The 100-liter model has a compact format of Ø440 mm and is designed for vertical wall-mounted installation, although the mini range also allows vertical floor-standing installation according to the manufacturer's instructions.
The Mecalia DPAC/DI/MCL 100 belongs to the manufacturer's range of compact buffer tanks, available in capacities from 30 to 100 liters.
It is intended to work with water from the primary circuit in systems where it is advisable to increase the available hydraulic volume, temporarily store energy or partially decouple heat or cold production from the installation's consumption.
It can be used with both hot and cold water, making it suitable for installations of:
The manufacturer expressly states that this buffer tank is not suitable for DHW.
It is designed exclusively to operate in a closed hydraulic circuit for heating or air conditioning. For this reason, it must not be used as a potable water storage tank or as a domestic hot water tank for human consumption.
The tank is made of carbon steel, a material suitable for closed primary circuits in thermal installations.
As it is intended for the technical circuit and not for sanitary water, it does not include the interior vitrification characteristic of DHW accumulators.
The compact DPAC/DI/MCL range from 30 to 100 liters is designed to operate at a maximum pressure of 6 bar.
This service pressure allows integration into numerous domestic and professional heating and air conditioning installations. The system must always include the corresponding safety valves and elements sized according to the characteristics of the installation.
The Mecalia DPAC/DI/MCL supports a maximum operating temperature of 90 °C.
This wide thermal range allows the tank to be used in both heating installations and hydraulic cooling systems, always within the limits established by Mecalia and the rest of the circuit components.
Buffer tanks are especially common in air source heat pump and heat pump installations, where they allow the amount of water available in the circuit to be increased.
Incorporating a properly sized buffer volume can help reduce generator start-stop cycles, stabilize hydraulic flow and provide a temporary thermal reserve.
The final sizing of the tank must be carried out according to the heat pump power, the existing water volume, the generator manufacturer's minimum flow requirements and the specific characteristics of the installation.
The tank can store cold or hot water from the primary circuit, so it is not limited only to heating applications.
It can also be used in air conditioning installations with a chiller or reversible heat pump to provide inertia to the circuit when the system is operating in cooling mode.
The tank incorporates insulation using injected rigid polyurethane foam, designed to reduce unwanted heat exchange between the stored water and the environment.
The insulation used by Mecalia is HCFC-free.
In this compact range, the manufacturer also uses an exterior finish with oven-lacquered sheet metal, providing mechanical protection for the insulation and a suitable finish for indoor technical installations.
Reference 12508 is included by Mecalia within the wall-mounted installation models of the DPAC/DI/MCL range.
Its reduced diameter of 440 mm makes it easier to place in technical rooms and other spaces where the aim is to limit the surface occupied by hydraulic components.
The manufacturer's current price list indicates the following approximate commercial dimensions for this reference:
The dimensional sheet for the DPAC/DI/MCL 100 shows different connections distributed vertically on both sides of the tank to facilitate hydraulic integration.
In the 100-liter model, the connections indicated in the technical drawing are 1½" female threads.
The design offers specific points for:
The arrangement of several outlets at different heights provides flexibility to adapt the hydraulic scheme to the needs of each installation.
According to Mecalia's technical drawing, the tank has several outlets specifically identified as connections to installation and connections to boiler.
This configuration makes it easier to use as an inertia element placed between the thermal generator and the distribution circuit.
The specific choice of connections to be used will depend on the hydraulic scheme, flow rates and the recommendations of the generator manufacturer.
The upper part includes a connection intended for venting or installation of a sensor.
This outlet can facilitate the evacuation of air accumulated in the upper area of the tank or allow the placement of a compatible measuring element according to the installation design.
At the bottom there is a connection identified for draining, facilitating maintenance and circuit drainage operations when necessary.
The Mecalia DPAC/DI/MCL 100 has an approximate empty weight of 29 kg.
It should be noted that once filled, the assembly increases considerably in weight. The wall fixing system and structural support must be sized to safely support the total weight of the full tank and the loads from the connected piping.
Adding a buffer tank increases the amount of water available within the circuit. This thermal reserve helps smooth rapid temperature variations and can reduce the frequency with which the generator needs to start and stop.
In installations with multiple circuits or variable demands, the additional volume can also help provide more stable hydraulic conditions.
The exact function and connection scheme must be determined during the design of the installation, as a buffer tank can be used in different ways depending on the generator, emitters and control system.
The Mecalia DPAC/DI/MCL 100 provides 100 additional liters of hydraulic volume in a compact wall-mounted format, making it a particularly useful solution for air source heat pump, heating and cooling systems where increased thermal inertia of the circuit is needed.
Its carbon steel construction, maximum pressure of 6 bar, service temperature of up to 90 °C, polyurethane insulation and multiple 1½" connections facilitate integration into different professional hydraulic schemes.
As it is intended exclusively for water from the primary circuit, it must always be used in a closed circuit and not as a domestic hot water storage tank.